Comparison of Tracheal Ultrasound With Capnography for Intubation Confirmation During CPR Wearing PPE
Comparison of Tracheal Ultrasound With Capnography for Intubation Confirmation During CPR (Cardiopulmonary Resuscitation) Wearing PPE (Personnel Protective Equipment): A Prospective Comparative Study
It is very important to ensure the tube placement in patients with cardiac arrest and unrecognized misplacement of endo-tracheal tube can lead to morbidity and mortality. In recent pandemic situations such as COVID-19 (Coronavirus disease-19), the number of cases of cardiopulmonary resuscitation with personal protective equipment (PPE) have increased. In those cases, existing methods such as auscultation and chest uprising have to be limited. Quantitative waveform capnography is recommended as the gold standard for confirming correct endotracheal tube placement in the 2010 American HeartAssociation (AHA) Guidelines for Cardiopulmonary resuscitation (CPR) and Emergency Cardiovascular Care (ECC), but it has some well-known limitations in cardiac arrest patients.
Ultrasonography is a non-invasive, real-time diagnostic tool commonly used during resuscitation. Especially, tracheal ultrasonography can be performed in real-time when the tube is passed through the trachea or esophagus. Previous prospective studies revealed that tracheal ultrasonography could feasibly and rapidly confirm tracheal intubation during emergency intubation.
There have already been several studies comparing the accuracy of tracheal ultrasound and capnography, but there was no study comparing the two tools under the constraints of PPE that is essential in pandemic situations as in this study. This study aimed to determine the accuracy of tracheal ultrasonography in assessing endotracheal tube position during CPR with PPE.
Studieöversikt
Status
Betingelser
Intervention / Behandling
Detaljerad beskrivning
Studietyp
Inskrivning (Förväntat)
Fas
- Inte tillämpbar
Kontakter och platser
Studieorter
-
-
-
Seoul, Korea, Republiken av, 06351
- Rekrytering
- Samsung Medical Center
-
Kontakt:
- Sooyeon Kang, fellow
- Telefonnummer: 82-10-3157-4718
- E-post: syrei3.kang@samsung.com
-
Kontakt:
- Hee Yoon, Professor
- Telefonnummer: 82-10-9933-5581
- E-post: wildhi.yoon@samsung.com
-
-
Deltagandekriterier
Urvalskriterier
Åldrar som är berättigade till studier
Tar emot friska volontärer
Kön som är behöriga för studier
Beskrivning
Inclusion Criteria:
- 1. cardiopulmonary arrest patients receiving emergency intubation and CPR
- 2. patients judged to need to wear PPE according to the judgement of the clinician
Exclusion Criteria:
- 1. sign for "do not resuscitate (DNR)"
- 2. patients unable to perform tracheal ultrasound due to trauma of the site
- 3. patients unable to perform tracheal ultrasound due to oropharynx cancer
- 4. patients unable to perform tracheal ultrasound due to placement of tracheal cannula
- 5. patients not used tracheal ultrasound for checking tube placement
Studieplan
Hur är studien utformad?
Designdetaljer
- Primärt syfte: Diagnostisk
- Tilldelning: N/A
- Interventionsmodell: Enskild gruppuppgift
- Maskning: Ingen (Open Label)
Vapen och interventioner
Deltagargrupp / Arm |
Intervention / Behandling |
|---|---|
|
Övrig: Tracheal ultrasound
The patients in cardiopulmonary arrest should be performed tracheal ultrasound when tube is passed through the trachea or esophagus.
|
When checking tracheal ultrasound, several signs are used in judgements.
Direct signs include reverberation artifact and double ring sign.
Indirect sign means checking the bilateral lung sliding.
|
Vad mäter studien?
Primära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
Accuracy
Tidsram: during intubation procedure
|
The gold standard is direct visualization using laryngoscopy.
Tracheal ultrasound is performed regardless of whether it is in real-time or not.
|
during intubation procedure
|
Samarbetspartners och utredare
Sponsor
Utredare
- Studiestol: Hee Yoon, Professor, Samsung medical center, Emergency department
Publikationer och användbara länkar
Studieavstämningsdatum
Studera stora datum
Studiestart (Faktisk)
Primärt slutförande (Förväntat)
Avslutad studie (Förväntat)
Studieregistreringsdatum
Först inskickad
Först inskickad som uppfyllde QC-kriterierna
Första postat (Faktisk)
Uppdateringar av studier
Senaste uppdatering publicerad (Faktisk)
Senaste inskickade uppdateringen som uppfyllde QC-kriterierna
Senast verifierad
Mer information
Termer relaterade till denna studie
Ytterligare relevanta MeSH-villkor
Andra studie-ID-nummer
- 2020-11-115
Plan för individuella deltagardata (IPD)
Planerar du att dela individuella deltagardata (IPD)?
Läkemedels- och apparatinformation, studiedokument
Studerar en amerikansk FDA-reglerad läkemedelsprodukt
Studerar en amerikansk FDA-reglerad produktprodukt
Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .