Comparison of Tracheal Ultrasound With Capnography for Intubation Confirmation During CPR Wearing PPE

30 maj 2021 uppdaterad av: Samsung Medical Center

Comparison of Tracheal Ultrasound With Capnography for Intubation Confirmation During CPR (Cardiopulmonary Resuscitation) Wearing PPE (Personnel Protective Equipment): A Prospective Comparative Study

It is very important to ensure the tube placement in patients with cardiac arrest and unrecognized misplacement of endo-tracheal tube can lead to morbidity and mortality. In recent pandemic situations such as COVID-19 (Coronavirus disease-19), the number of cases of cardiopulmonary resuscitation with personal protective equipment (PPE) have increased. In those cases, existing methods such as auscultation and chest uprising have to be limited. Quantitative waveform capnography is recommended as the gold standard for confirming correct endotracheal tube placement in the 2010 American HeartAssociation (AHA) Guidelines for Cardiopulmonary resuscitation (CPR) and Emergency Cardiovascular Care (ECC), but it has some well-known limitations in cardiac arrest patients.

Ultrasonography is a non-invasive, real-time diagnostic tool commonly used during resuscitation. Especially, tracheal ultrasonography can be performed in real-time when the tube is passed through the trachea or esophagus. Previous prospective studies revealed that tracheal ultrasonography could feasibly and rapidly confirm tracheal intubation during emergency intubation.

There have already been several studies comparing the accuracy of tracheal ultrasound and capnography, but there was no study comparing the two tools under the constraints of PPE that is essential in pandemic situations as in this study. This study aimed to determine the accuracy of tracheal ultrasonography in assessing endotracheal tube position during CPR with PPE.

Studieöversikt

Status

Okänd

Intervention / Behandling

Detaljerad beskrivning

When patients in cardiopulmonary arrest enter a emergency room (ER) or patients staying in a ER have a cardiopulmonary arrest, participants perform intubation and CPR. When it is judged as a high-risk group with a high probability of droplet infection, all participants in resuscitation team should wear personal protective equipment. Tracheal ultrasound and end-tidal carbon dioxide are used to confirm the placement of tube. The gold standard is the direct visualization using laryngoscope. The time it takes to confirm the placement of tube is also measured.

Studietyp

Interventionell

Inskrivning (Förväntat)

34

Fas

  • Inte tillämpbar

Kontakter och platser

Det här avsnittet innehåller kontaktuppgifter för dem som genomför studien och information om var denna studie genomförs.

Studieorter

Deltagandekriterier

Forskare letar efter personer som passar en viss beskrivning, så kallade behörighetskriterier. Några exempel på dessa kriterier är en persons allmänna hälsotillstånd eller tidigare behandlingar.

Urvalskriterier

Åldrar som är berättigade till studier

18 år till 100 år (Vuxen, Äldre vuxen)

Tar emot friska volontärer

Nej

Kön som är behöriga för studier

Allt

Beskrivning

Inclusion Criteria:

  • 1. cardiopulmonary arrest patients receiving emergency intubation and CPR
  • 2. patients judged to need to wear PPE according to the judgement of the clinician

Exclusion Criteria:

  • 1. sign for "do not resuscitate (DNR)"
  • 2. patients unable to perform tracheal ultrasound due to trauma of the site
  • 3. patients unable to perform tracheal ultrasound due to oropharynx cancer
  • 4. patients unable to perform tracheal ultrasound due to placement of tracheal cannula
  • 5. patients not used tracheal ultrasound for checking tube placement

Studieplan

Det här avsnittet ger detaljer om studieplanen, inklusive hur studien är utformad och vad studien mäter.

Hur är studien utformad?

Designdetaljer

  • Primärt syfte: Diagnostisk
  • Tilldelning: N/A
  • Interventionsmodell: Enskild gruppuppgift
  • Maskning: Ingen (Open Label)

Vapen och interventioner

Deltagargrupp / Arm
Intervention / Behandling
Övrig: Tracheal ultrasound
The patients in cardiopulmonary arrest should be performed tracheal ultrasound when tube is passed through the trachea or esophagus.
When checking tracheal ultrasound, several signs are used in judgements. Direct signs include reverberation artifact and double ring sign. Indirect sign means checking the bilateral lung sliding.

Vad mäter studien?

Primära resultatmått

Resultatmått
Åtgärdsbeskrivning
Tidsram
Accuracy
Tidsram: during intubation procedure
The gold standard is direct visualization using laryngoscopy. Tracheal ultrasound is performed regardless of whether it is in real-time or not.
during intubation procedure

Samarbetspartners och utredare

Det är här du hittar personer och organisationer som är involverade i denna studie.

Utredare

  • Studiestol: Hee Yoon, Professor, Samsung medical center, Emergency department

Publikationer och användbara länkar

Den som ansvarar för att lägga in information om studien tillhandahåller frivilligt dessa publikationer. Dessa kan handla om allt som har med studien att göra.

Studieavstämningsdatum

Dessa datum spårar framstegen för inlämningar av studieposter och sammanfattande resultat till ClinicalTrials.gov. Studieposter och rapporterade resultat granskas av National Library of Medicine (NLM) för att säkerställa att de uppfyller specifika kvalitetskontrollstandarder innan de publiceras på den offentliga webbplatsen.

Studera stora datum

Studiestart (Faktisk)

30 januari 2021

Primärt slutförande (Förväntat)

1 februari 2022

Avslutad studie (Förväntat)

1 juli 2022

Studieregistreringsdatum

Först inskickad

21 december 2020

Först inskickad som uppfyllde QC-kriterierna

27 december 2020

Första postat (Faktisk)

30 december 2020

Uppdateringar av studier

Senaste uppdatering publicerad (Faktisk)

2 juni 2021

Senaste inskickade uppdateringen som uppfyllde QC-kriterierna

30 maj 2021

Senast verifierad

1 december 2020

Mer information

Termer relaterade till denna studie

Ytterligare relevanta MeSH-villkor

Andra studie-ID-nummer

  • 2020-11-115

Plan för individuella deltagardata (IPD)

Planerar du att dela individuella deltagardata (IPD)?

Nej

Läkemedels- och apparatinformation, studiedokument

Studerar en amerikansk FDA-reglerad läkemedelsprodukt

Nej

Studerar en amerikansk FDA-reglerad produktprodukt

Nej

Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .