Comparison of Tracheal Ultrasound With Capnography for Intubation Confirmation During CPR Wearing PPE
Comparison of Tracheal Ultrasound With Capnography for Intubation Confirmation During CPR (Cardiopulmonary Resuscitation) Wearing PPE (Personnel Protective Equipment): A Prospective Comparative Study
It is very important to ensure the tube placement in patients with cardiac arrest and unrecognized misplacement of endo-tracheal tube can lead to morbidity and mortality. In recent pandemic situations such as COVID-19 (Coronavirus disease-19), the number of cases of cardiopulmonary resuscitation with personal protective equipment (PPE) have increased. In those cases, existing methods such as auscultation and chest uprising have to be limited. Quantitative waveform capnography is recommended as the gold standard for confirming correct endotracheal tube placement in the 2010 American HeartAssociation (AHA) Guidelines for Cardiopulmonary resuscitation (CPR) and Emergency Cardiovascular Care (ECC), but it has some well-known limitations in cardiac arrest patients.
Ultrasonography is a non-invasive, real-time diagnostic tool commonly used during resuscitation. Especially, tracheal ultrasonography can be performed in real-time when the tube is passed through the trachea or esophagus. Previous prospective studies revealed that tracheal ultrasonography could feasibly and rapidly confirm tracheal intubation during emergency intubation.
There have already been several studies comparing the accuracy of tracheal ultrasound and capnography, but there was no study comparing the two tools under the constraints of PPE that is essential in pandemic situations as in this study. This study aimed to determine the accuracy of tracheal ultrasonography in assessing endotracheal tube position during CPR with PPE.
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Descripción detallada
Tipo de estudio
Inscripción (Anticipado)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
-
Seoul, Corea, república de, 06351
- Reclutamiento
- Samsung Medical Center
-
Contacto:
- Sooyeon Kang, fellow
- Número de teléfono: 82-10-3157-4718
- Correo electrónico: syrei3.kang@samsung.com
-
Contacto:
- Hee Yoon, Professor
- Número de teléfono: 82-10-9933-5581
- Correo electrónico: wildhi.yoon@samsung.com
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- 1. cardiopulmonary arrest patients receiving emergency intubation and CPR
- 2. patients judged to need to wear PPE according to the judgement of the clinician
Exclusion Criteria:
- 1. sign for "do not resuscitate (DNR)"
- 2. patients unable to perform tracheal ultrasound due to trauma of the site
- 3. patients unable to perform tracheal ultrasound due to oropharynx cancer
- 4. patients unable to perform tracheal ultrasound due to placement of tracheal cannula
- 5. patients not used tracheal ultrasound for checking tube placement
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Diagnóstico
- Asignación: N / A
- Modelo Intervencionista: Asignación de un solo grupo
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Otro: Tracheal ultrasound
The patients in cardiopulmonary arrest should be performed tracheal ultrasound when tube is passed through the trachea or esophagus.
|
When checking tracheal ultrasound, several signs are used in judgements.
Direct signs include reverberation artifact and double ring sign.
Indirect sign means checking the bilateral lung sliding.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Accuracy
Periodo de tiempo: during intubation procedure
|
The gold standard is direct visualization using laryngoscopy.
Tracheal ultrasound is performed regardless of whether it is in real-time or not.
|
during intubation procedure
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Silla de estudio: Hee Yoon, Professor, Samsung medical center, Emergency department
Publicaciones y enlaces útiles
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Anticipado)
Finalización del estudio (Anticipado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- 2020-11-115
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .