Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Closed-loop Oxygen Control for High Flow Nasal Therapy (HILOOP)

Safety and Efficacy of a Closed-loop Oxygen Control for High Flow Nasal Therapy in ICU Patients: a Randomized Cross-over Study (The HILOOP Study)

In patients with acute hypoxemic respiratory failure (AHRF), High Flow Nasal Therapy (HFNT) improves oxygenation, tolerance, and decrease work of breathing as compared to standard oxygen therapy by facemask. Current guidelines recommend adjusting oxygen flow rates to keep the oxygen saturation measured by pulse oximetry (SpO2) in the target range and avoid hypoxemia and hyperoxemia. The hypothesis of the study is that closed loop oxygen control increases the time spent within clinically targeted SpO2 ranges and decreases the time spent outside clinical target SpO2 ranges as compared to manual oxygen control in ICU patients treated with HFNT.

Aperçu de l'étude

Type d'étude

Interventionnel

Inscription (Réel)

53

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

      • Barcelona, Espagne, 08035
        • Hospital Universitari Vall d'Hebron

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans et plus (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

La description

Inclusion Criteria:

  • Adult (>17yo) patients admitted to the ICU treated with HFNT for at least 8h
  • Requiring FiO2 ≥ 30% to keep SpO2 in the target ranges defined by the clinician
  • Written informed consent signed and dated by the patient or one relative in case that the patient is unable to consent, after full explanation of the study by the investigator and prior to study participation.

Exclusion Criteria:

  • Patient with indication for immediate continuous positive airway pressure (CPAP), noninvasive ventilation (NIV), or invasive mechanical ventilation
  • Hemodynamic instability defined as a need of continuous infusion of epinephrine or norepinephrine > 1 mg/h
  • Low quality on the SpO2 measurement using finger and ear sensor (quality index below 60% on the Massimo SpO2 sensor, which is displayed by a red or orange colour bar)
  • Severe acidosis (pH ≤ 7.30)
  • Pregnant woman
  • Patients deemed at high risk for need of mechanical ventilation within the next 8 hours
  • Chronic or acute dyshemoglobinemia: methemoglobin, carbon monoxide (CO) poisoning, sickle cell disease
  • Tracheotomised patient
  • Formalized ethical decision to withhold or withdraw life support
  • Patient under guardianship
  • Patient deprived of liberties
  • Patient included in another interventional research study under consent
  • Patient already enrolled in the present study in a previous episode of acute respiratory failure

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation croisée
  • Masquage: Seul

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: Oxygen close-loop
Four hours period where the fraction of inspired oxygen delivered will be automatically titrated based on SpO2 values.
The Automatic FiO2 option provides automated adjustment of the ventilator Oxygen setting to maintain the patient's SpO2 in a defined target range. When using the software option, the user defines the SpO2 target range, as well as the SpO2 emergency limits, and the device adjusts the Oxygen setting to keep the patient's SpO2 in the target range.
Comparateur actif: Manual FiO2 adjustment
Four hours period where the fraction of inspired oxygen delivered will be manually adjusted by the healthcare personnel based on SpO2 values.
Manual FiO2 adjustment according to SpO2 values

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Percentage of time spent in optimal SpO2 range
Délai: 4 hours
The optimal SpO2 range will be defined according to the SpO2 targets determined by the clinician.
4 hours

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Percentage of time spent in sub-optimal SpO2 range
Délai: 4 hours
SpO2 values outside the optimal range but still within an acceptable limit (2-3 percent above and below the optimal range)
4 hours
Percentage of time spent out of range
Délai: 4 hours
Above or below the suboptimal limits specified at the begginning of the study
4 hours
Percentage of time with SpO2 signal available
Délai: 4 hours
Time with SpO2 signal available
4 hours
Mean SpO2/FiO2
Délai: 4 hours
Mean oxygenation value
4 hours
ROX index
Délai: 4 hours
Is a predictor of HFNT success/failure defined as (SpO2/FiO2)/respiratory rate
4 hours
Percentage of time with SpO2 below 88 and 85 percent
Délai: 4 hours
Duration of time with SpO2 <85 percent and <88 percent, respectively
4 hours
Number of events with SpO2 below 88 and 85 percent
Délai: 4 hours
Frequency of SpO2 decreases <85 percent and <88 percent, respectively
4 hours
Mean FiO2
Délai: 4 hours
Mean fraction of inspired oxygen
4 hours
Percentage of time with FiO2 below 40 percent and above 60%
Délai: 4 hours
Percentage of time that FiO2 is <40 percent and >60 percent, respectively
4 hours
Number of manual adjustments
Délai: 4 hours
Frequency of manual adjustments of FiO2
4 hours
Number of alarms
Délai: 4 hours
Frequency of alarms
4 hours
Patient comfort
Délai: 4 hours
Comfort score by visual analogic scale (from 0 to 10)
4 hours

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

27 avril 2021

Achèvement primaire (Réel)

10 août 2021

Achèvement de l'étude (Réel)

10 août 2021

Dates d'inscription aux études

Première soumission

4 mai 2021

Première soumission répondant aux critères de contrôle qualité

7 juillet 2021

Première publication (Réel)

16 juillet 2021

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

9 décembre 2021

Dernière mise à jour soumise répondant aux critères de contrôle qualité

26 novembre 2021

Dernière vérification

1 octobre 2021

Plus d'information

Termes liés à cette étude

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner