Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Correlation of Cardiac Index Measured by the PRAM Method With NIRS and Lactate Levels in Pediatric Aortic Coarctation Surgery (MostCare-Ped)

28 avril 2026 mis à jour par: BEDİA MİNE HANEDAN, Konya City Hospital

Correlation of Cardiac Index Measured by the Pressure Recording Analytical Method (PRAM) With Near-Infrared Spectroscopy (NIRS) and Arterial Lactate Levels in Neonates and Infants Undergoing Surgical Repair of Aortic Coarctation: A Prospective Observational Study

This prospective observational study aims to evaluate the correlation between cardiac index measured by the MostCare™ system (Pressure Recording Analytical Method, PRAM) and cerebral/renal regional oxygen saturation measured by near-infrared spectroscopy (NIRS) and arterial lactate levels in neonates and infants (body weight 2.5-3.5 kg, age 0-3 months) undergoing surgical repair of aortic coarctation. Measurements will be recorded at four intraoperative time points: after anesthesia induction, before aortic cross-clamp, 3 minutes after cross-clamp release, and at end of surgery. No additional intervention beyond standard anesthesia and surgical care will be applied.

Aperçu de l'étude

Description détaillée

Low cardiac output syndrome (LCOS) is a major determinant of postoperative morbidity and mortality in neonatal cardiac surgery, particularly in lesions affecting systemic circulation such as aortic coarctation. Reliable intraoperative assessment of cardiac output is therefore critical in this patient population.

The MostCare™ system uses the Pressure Recording Analytical Method (PRAM) to provide real-time, calibration-free cardiac index (CI) measurement derived solely from the arterial pressure waveform. Previous studies in infants have demonstrated good correlation between PRAM and echocardiography; however, data in neonates weighing less than 3.5 kg remain very limited.

Near-infrared spectroscopy (NIRS) allows non-invasive monitoring of regional cerebral and renal oxygen saturation (rSO2), serving as an early indicator of tissue oxygenation. Arterial lactate is a biochemical marker of cellular hypoperfusion and is strongly associated with postoperative outcomes.

In this study, CI (MostCare™), cerebral and renal NIRS (INVOS™ oximeter), and arterial lactate will be simultaneously recorded at four intraoperative time points in neonates and infants undergoing aortic coarctation repair. The primary aim is to assess the correlation between PRAM-derived CI and cerebral NIRS. Secondary aims include the correlation between CI and renal NIRS, and between CI and arterial lactate levels.

Type d'étude

Observationnel

Inscription (Estimé)

43

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

Lieux d'étude

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Enfant

Accepte les volontaires sains

Non

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

Neonates and infants aged 0-3 months with body weight 2.5-3.5 kg diagnosed with aortic coarctation and scheduled for surgical repair at SBU Konya City Hospital, Konya, Turkey.

La description

Inclusion Criteria:

  • Neonates and infants planned for surgical repair of aortic coarctation
  • Body weight between 2.5 and 3.5 kg
  • Postnatal age between 0 and 3 months
  • Considered hemodynamically stable for anesthesia and surgery
  • Written informed consent obtained from legal guardians

Exclusion Criteria:

  • Severe multiorgan dysfunction
  • Additional major congenital heart defect (e.g., Tetralogy of Fallot, Transposition of Great Arteries, Hypoplastic Left Heart Syndrome)
  • Surgery requiring cardiopulmonary bypass
  • Preoperative metabolic acidosis or sepsis
  • Inability to obtain informed consent from legal guardians

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Cohortes et interventions

Groupe / Cohorte
Intervention / Traitement
Aortic Coarctation Surgery Group
Neonates and infants aged 0-3 months with body weight 2.5-3.5 kg undergoing surgical repair of aortic coarctation. Cardiac index (MostCare™/PRAM), cerebral and renal NIRS (INVOS™), and arterial lactate levels are recorded at four intraoperative time points under standard anesthesia protocol.
Real-time, calibration-free cardiac index monitoring via arterial pressure waveform analysis using the MostCare™ system. Used as part of routine intraoperative hemodynamic monitoring.
Autres noms:
  • Pressure Recording Analytical Method
Non-invasive monitoring of regional cerebral and renal oxygen saturation (rSO2) using the INVOS™ oximeter as part of standard intraoperative care.
Autres noms:
  • INVOS Oximeter
Arterial blood gas sampling for lactate measurement at four intraoperative time points as part of routine clinical monitoring.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Correlation between PRAM-derived Cardiac Index and Cerebral NIRS (rSO2c)
Délai: Intraoperative (at 4 time points: after anesthesia induction, before aortic cross-clamp, 3 minutes after cross-clamp release, and at end of surgery)
Pearson or Spearman correlation coefficient between cardiac index (CI, L/min/m²) measured by MostCare™ (PRAM method) and cerebral regional oxygen saturation (rSO2c, %) measured by INVOS™ oximeter at four intraoperative time points.
Intraoperative (at 4 time points: after anesthesia induction, before aortic cross-clamp, 3 minutes after cross-clamp release, and at end of surgery)

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Correlation between PRAM-derived Cardiac Index and Renal NIRS (rSO2r)
Délai: Intraoperative (at 4 time points: after anesthesia induction, before aortic cross-clamp, 3 minutes after cross-clamp release, and at end of surgery)
Pearson or Spearman correlation coefficient between cardiac index (CI, L/min/m²) and renal regional oxygen saturation (rSO2r, %) at four intraoperative time points.
Intraoperative (at 4 time points: after anesthesia induction, before aortic cross-clamp, 3 minutes after cross-clamp release, and at end of surgery)
Correlation between PRAM-derived Cardiac Index and Arterial Lactate Level
Délai: Intraoperative (at 4 time points: after anesthesia induction, before aortic cross-clamp, 3 minutes after cross-clamp release, and at end of surgery)
Pearson or Spearman correlation coefficient between cardiac index (CI, L/min/m²) and arterial lactate level (mmol/L) at four intraoperative time points.
Intraoperative (at 4 time points: after anesthesia induction, before aortic cross-clamp, 3 minutes after cross-clamp release, and at end of surgery)

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Les enquêteurs

  • Chercheur principal: Bedia Mine Hanedan, MD, Konya City Hospital

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Estimé)

1 mai 2026

Achèvement primaire (Estimé)

1 décembre 2026

Achèvement de l'étude (Estimé)

1 mars 2027

Dates d'inscription aux études

Première soumission

28 avril 2026

Première soumission répondant aux critères de contrôle qualité

28 avril 2026

Première publication (Réel)

5 mai 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

5 mai 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

28 avril 2026

Dernière vérification

1 avril 2026

Plus d'information

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner