- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT07650188
Stimulating the Aging Brain Using Brain and Sensory Stimulation (StAB)
Stimulating the Aging Brain: Noninvasive Brain and Sensory Stimulation Strategies in Aging
The goal of this project is to investigate whether transcranial electrical stimulation and sensory stimulation affect language outcomes in individuals with primary progressive aphasia (PPA). The main questions it aims to answer are:
Does transcranial alternating current stimulation (tACS) affect verbal short-term memory (STM) in individuals with PPA? Does a single session of multisensory stimulation affect verbal STM in individuals with PPA? Researchers will compare active tACS to sham tACS (a fake stimulation condition) to see if active tACS improves verbal STM. Researchers will compare pre-multisensory stimulation to post-stimulation performance to see if multisensory stimulation improves verbal STM.
Participants will:
Undergo EEG, MRI (anatomical and functional) May complete a cognitive exam Undergo tACS over 3 separate sessions Undergo multisensory stimulation Complete language tasks before, during and/or after stimulation
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Type d'étude
Inscription (Estimé)
Phase
- N'est pas applicable
Contacts et emplacements
Coordonnées de l'étude
- Nom: Sidney Schoenrock, MA
- Numéro de téléphone: 414-955-7579
- E-mail: sschoenrock@mcw.edu
Lieux d'étude
-
-
Wisconsin
-
Milwaukee, Wisconsin, États-Unis, 53226
- Recrutement
- Medical College of Wisconsin
-
Contact:
- Sidney Schoenrock, MA
- Numéro de téléphone: 414-955-7579
- E-mail: sschoenrock@mcw.edu
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
La description
Inclusion Criteria:
- Clinical exam supports diagnosis of PPA and/or MCI with no report of difficulty functioning in basic or instrumental activities of daily living.
- Completed clinical cognitive exam within 6 months of study baseline visit OR neuropsychological research battery within 6 months of study baseline visit.
Exclusion Criteria:
- Evidence of dementia at baseline
- Known history of neoplasm, symptomatic stroke, moderate to severe traumatic brain injury, or other significant neurologic event
- Age <45 years.
- Evidence of severe psychiatric illness (e.g., bipolar disorder, schizophrenia).
- Presence of cardiac stimulators or pacemakers
- Any other implants near the scalp or in the eye
- Contraindications to MRI or stimulation
- Pregnancy
- History of ongoing or unmanaged seizures
- History of dyslexia or other developmental learning disabilities
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Science basique
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: tACS or multisensory stimulation
All participants in a within-subject design will receive high-Definition-tACS, delivered via a battery operated alternating current stimulator (Soterix) using two center-surround montages. Targets of stimulation will be localized based on the 10-10 International EEG system with center electrodes placed at a frontal and a temporoparietal site. The current is turned on and increased in a ramplike fashion over approximately 30 seconds. Participants will undergo tACS with frequencies ranging from 4-40Hz for 20-minutes with 2 milliampere (mA) peak-to-peak intensity. For sham stimulation, tACS is turned off after the first 30 seconds. All participants will receive light and/or sound flicker stimulation using an off-the-shelf app for 20 minutes. |
Active or sham tACS Light and/or sound flickers
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Changes in STM capacity assessed using a verbal STM task
Délai: Changes monitored over pre, during and immediately after 20 minutes of tACS
|
Improvement in STM capacity with in-phase tACS and worsening of STM capacity with anti-phase tACS compared to sham tACS
|
Changes monitored over pre, during and immediately after 20 minutes of tACS
|
|
Changes in STM capacity with multisensory stimulation using a verbal STM task
Délai: Changes monitored pre and immediately after 20 minutes of stimulation
|
Improvement in STM capacity post-stimulation compared to pre-stimulation
|
Changes monitored pre and immediately after 20 minutes of stimulation
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Priyanka Shah-Basak, PhD, Medical College of Wisconsin
Publications et liens utiles
Publications générales
- Martorell AJ, Paulson AL, Suk HJ, Abdurrob F, Drummond GT, Guan W, Young JZ, Kim DN, Kritskiy O, Barker SJ, Mangena V, Prince SM, Brown EN, Chung K, Boyden ES, Singer AC, Tsai LH. Multi-sensory Gamma Stimulation Ameliorates Alzheimer's-Associated Pathology and Improves Cognition. Cell. 2019 Apr 4;177(2):256-271.e22. doi: 10.1016/j.cell.2019.02.014. Epub 2019 Mar 14.
- Iaccarino HF, Singer AC, Martorell AJ, Rudenko A, Gao F, Gillingham TZ, Mathys H, Seo J, Kritskiy O, Abdurrob F, Adaikkan C, Canter RG, Rueda R, Brown EN, Boyden ES, Tsai LH. Gamma frequency entrainment attenuates amyloid load and modifies microglia. Nature. 2016 Dec 7;540(7632):230-235. doi: 10.1038/nature20587.
- Hu J, Zheng L, Guan Z, Zhong K, Huang F, Huang Q, Yang J, Li W, Li S. Sensory gamma entrainment: Impact on amyloid protein and therapeutic mechanism. Brain Res Bull. 2023 Oct 1;202:110750. doi: 10.1016/j.brainresbull.2023.110750. Epub 2023 Aug 23.
- McNett SD, Vyshedskiy A, Savchenko A, Durakovic D, Heredia G, Cahn R, Kogan M. A Feasibility Study of AlzLife 40 Hz Sensory Therapy in Patients with MCI and Early AD. Healthcare (Basel). 2023 Jul 17;11(14):2040. doi: 10.3390/healthcare11142040.
- Tang Y, Xing Y, Sun L, Wang Z, Wang C, Yang K, Zhu W, Shi X, Xie B, Yin Y, Mi Y, Wei T, Tong R, Qiao Y, Yan S, Wei P, Yang Y, Shan Y, Zhang X, Jia J, Teipel SJ, Howard R, Lu J, Li C, Zhao G. TRanscranial AlterNating current stimulation FOR patients with mild Alzheimer's Disease (TRANSFORM-AD): a randomized controlled clinical trial. Alzheimers Res Ther. 2024 Sep 12;16(1):203. doi: 10.1186/s13195-024-01570-0.
- Altomare D, Benussi A, Cantoni V, Premi E, Rivolta J, Cupidi C, Martorana A, Santarnecchi E, Padovani A, Koch G, Borroni B. Home-based transcranial alternating current stimulation (tACS) in Alzheimer's disease: rationale and study design. Alzheimers Res Ther. 2023 Sep 15;15(1):155. doi: 10.1186/s13195-023-01297-4.
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
- Manifestations neurologiques
- Maladies du cerveau
- Maladies du système nerveux central
- Maladies du système nerveux
- Les troubles mentaux
- Manifestations neurocomportementales
- Troubles neurocognitifs
- Démence
- Troubles de la communication
- Troubles du langage
- Aphasie
- Troubles de la parole
- Conditions pathologiques, signes et symptômes
- Signes et symptômes
- Aphasie primaire progressive
Autres numéros d'identification d'étude
- PRO00056114
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
produit fabriqué et exporté des États-Unis.
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .