Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Clinical Evaluation of Prefabricated Versus 3D-Printed Composite Resin Veneers: in Vivo Study

2 juillet 2026 mis à jour par: Mohammed Abd El Ghany Mohammed, Tanta University
The purpose of this study is to clinically evaluate prefabricated versus 3D-printed composite resin veneers

Aperçu de l'étude

Description détaillée

Dental veneers are now a commonly used conservative treatment to improve the appearance and functionality of anterior teeth that have enamel flaws, diastemas, small abnormalities, and discoloration. Compared to ceramic veneers, composite resin veneers have a number of benefits, such as requiring less tooth preparation, being less expensive, being easier to repair, and requiring less chairside time. Recent developments in composite resin technology and adhesive dentistry have further enhanced their mechanical qualities, wear resistance, and aesthetic results, making them a desirable treatment option for patients and professionals alike. There is little clinical data that directly compares the long-term performance of prefabricated and 3D-printed composite veneers, despite their growing use. The majority of research that is currently available has either examined each technique separately or has concentrated on laboratory assessments of mechanical properties. As a result, there is still not enough data to compare their clinical behavior in intraoral settings.

Type d'étude

Interventionnel

Inscription (Réel)

40

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • Tanta
      • Tanta, Tanta, Egypte, 31527
        • Restorative Department, Faculty of Dentistry, Tanta University

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte

Accepte les volontaires sains

Oui

La description

Inclusion Criteria:

  • Good oral hygiene and satisfactory periodontal health
  • Patients requiring esthetic rehabilitation of anterior teeth
  • Presence of enough enamel for bonding

Exclusion Criteria:

  • Non-vital teeth or teeth requiring endodontic treatment
  • Severe malocclusion or parafunctional habits (e.g., bruxism or clenching)
  • Patients with severe intrinsic discoloration requiring alternative treatment

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Double

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: Prefabricated Composite Resin Veneers
Participants received prefabricated composite resin veneer restorations for the treatment of anterior teeth requiring esthetic rehabilitation. Veneers were placed according to the manufacturer's instructions using a standardized adhesive protocol.
Prefabricated composite resin veneer restorations used for esthetic rehabilitation of anterior teeth. Restorations will be bonded following the manufacturer's recommended adhesive protocol.
Expérimental: 3D-Printed Composite Resin Veneers
Participants received customized 3D-printed composite resin veneer restorations for the treatment of anterior teeth requiring esthetic rehabilitation. Veneers were fabricated using a digital workflow and cemented according to the manufacturer's instructions using a standardized adhesive protocol
Customized 3D-printed composite resin veneer restorations fabricated using digital design and additive manufacturing technology and bonded according to the manufacturer's recommended adhesive protocol

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Color match and stability
Délai: 24 months
Clinical evaluation of color match and color stability will be performed according to the World Dental Federation (FDI) evaluation criteria by two calibrated evaluators at baseline and at 6, 9, 12, and 24 months. Veneer restorations will be assigned FDI scores ranging from 1 (clinically excellent) to 5 (clinically poor). Clinical success will be considered as scores of 1-3 and failure as scores of 4-5. Assessment will be carried out under standardized lighting conditions using visual examination and magnification. Statistical analysis will be performed to compare changes over time and between the two study groups.
24 months

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Parrainer

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

25 avril 2025

Achèvement primaire (Estimé)

26 avril 2027

Achèvement de l'étude (Estimé)

29 avril 2027

Dates d'inscription aux études

Première soumission

2 juillet 2026

Première soumission répondant aux critères de contrôle qualité

2 juillet 2026

Première publication (Réel)

9 juillet 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

9 juillet 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

2 juillet 2026

Dernière vérification

1 juillet 2026

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • Composite Resin Veneers

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner