Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Evaluation of Maxillary Buccal Miniscrew Insertion Using Digital Guides

7 juillet 2026 mis à jour par: Can Tho University of Medicine and Pharmacy
This randomized split-mouth clinical trial aims to compare the accuracy and clinical outcomes of CAD/CAM 3D-printed surgical guides with the conventional free-hand technique for orthodontic miniscrew placement in the posterior maxilla. Each participant will receive miniscrew placement using both techniques on opposite sides of the maxilla following random allocation. The primary outcome is placement accuracy assessed by three-dimensional positional and angular deviations between planned and actual miniscrew positions. Secondary outcomes include miniscrew stability, success rate after three months, postoperative pain, procedural time, patient satisfaction, and complications. The study also evaluates maxillary posterior cortical bone thickness using cone-beam computed tomography (CBCT) and investigates its relationship with miniscrew placement accuracy and stability

Aperçu de l'étude

Description détaillée

Orthodontic miniscrews have become an effective source of temporary skeletal anchorage because they provide absolute anchorage with minimal dependence on patient compliance. However, the success of orthodontic miniscrews largely depends on accurate insertion while avoiding adjacent anatomical structures, particularly dental roots and the maxillary sinus. Incorrect placement may lead to root damage, instability, or failure of the miniscrew Cone-beam computed tomography (CBCT) allows three-dimensional evaluation of alveolar bone morphology and cortical bone thickness before miniscrew insertion. Digital technologies combining CBCT, intraoral scanning, CAD/CAM planning, and three-dimensional printing have enabled fabrication of customized surgical guides designed to improve insertion accuracy This study is designed as a randomized split-mouth controlled clinical trial. Patients requiring bilateral orthodontic miniscrews in the posterior maxilla will receive one miniscrew inserted using a CAD/CAM 3D-printed surgical guide and the contralateral miniscrew inserted using the conventional free-hand technique. The side allocated to each intervention and the order of insertion will be randomized Placement accuracy will be evaluated by superimposing preoperative planning data with postoperative digital models using Geomagic Studio software. Three-dimensional deviations, including coronal and apical positional deviations and angular deviations, will be calculated. Miniscrew stability, success rate after three months, postoperative pain measured by the Visual Analog Scale (VAS), patient satisfaction, operative time, and treatment-related complications will also be evaluated. Additionally, CBCT will be used to measure cortical bone thickness at multiple posterior maxillary interradicular sites, and correlations between cortical bone thickness and miniscrew accuracy and stability will be analyzed

Type d'étude

Interventionnel

Inscription (Réel)

33

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

      • Can Tho, Viêt Nam, +84
        • Can Tho University of Medicine and Pharmacy

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte
  • Adulte plus âgé

Accepte les volontaires sains

Oui

La description

Inclusion Criteria:

  • Adults aged 18 years or older.
  • Patients requiring bilateral orthodontic miniscrew placement in the posterior maxilla as part of orthodontic treatment.
  • Availability of high-quality cone-beam computed tomography (CBCT) images suitable for evaluation and digital planning.
  • Good general health and ability to undergo orthodontic treatment.
  • Healthy periodontal tissues at the planned miniscrew insertion sites.
  • Ability and willingness to provide written informed consent.

Exclusion Criteria:

  • Systemic diseases or medications affecting bone healing or bone metabolism.
  • Bleeding disorders or contraindications to minor oral surgery.
  • Active periodontal disease or local infection at the planned insertion site.
  • Poor-quality or incomplete CBCT images.
  • Contraindications to CBCT imaging.
  • Pregnancy or lactation.
  • Previous orthodontic miniscrew placement in the planned insertion area.
  • Refusal or inability to provide informed consent.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Seul

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: CAD/CAM-Guided Miniscrew Placement
Miniscrew placement using a customized CAD/CAM 3D-printed surgical guide.
A customized tooth-supported CAD/CAM-designed and 3D-printed surgical guide fabricated from CBCT and intraoral scan data to assist accurate orthodontic miniscrew insertion in the posterior maxilla according to the preoperative digital treatment plan.
Comparateur actif: Free-Hand Miniscrew Placement
Conventional free-hand orthodontic miniscrew placement.
Orthodontic miniscrews are inserted manually using the conventional free-hand technique without the assistance of a surgical guide, based on the clinician's clinical judgment and anatomical landmarks.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Accuracy of Orthodontic Miniscrew Placement
Délai: Immediately after miniscrew placement
Placement accuracy will be assessed by comparing the planned and actual miniscrew positions using digital superimposition. Coronal and apical three-dimensional deviations together with angular deviations will be calculated using Geomagic Studio software.
Immediately after miniscrew placement

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Miniscrew Success Rate
Délai: 3 months
Clinical success defined as stable miniscrews remaining functional for orthodontic anchorage.
3 months
Miniscrew Stability
Délai: Immediately after insertion, 1 week, 1 month, and 3 months.
Clinical assessment of miniscrew stability after insertion.
Immediately after insertion, 1 week, 1 month, and 3 months.
Three-Dimensional Miniscrew Displacement
Délai: 3 months.
Changes in miniscrew position between immediate postoperative and 3-month evaluations
3 months.

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Les enquêteurs

  • Chercheur principal: Lam Nguyen Le, Assoc. Prof., Faculty of Odonto-Stomatology, Can Tho University of Medicine and Pharmacy

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

1 novembre 2025

Achèvement primaire (Réel)

1 juin 2026

Achèvement de l'étude (Réel)

1 juin 2026

Dates d'inscription aux études

Première soumission

7 juillet 2026

Première soumission répondant aux critères de contrôle qualité

7 juillet 2026

Première publication (Réel)

13 juillet 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

13 juillet 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

7 juillet 2026

Dernière vérification

1 juillet 2026

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • LeNguyenLam

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner