Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Evaluation of Maxillary Buccal Miniscrew Insertion Using Digital Guides

7 luglio 2026 aggiornato da: Can Tho University of Medicine and Pharmacy
This randomized split-mouth clinical trial aims to compare the accuracy and clinical outcomes of CAD/CAM 3D-printed surgical guides with the conventional free-hand technique for orthodontic miniscrew placement in the posterior maxilla. Each participant will receive miniscrew placement using both techniques on opposite sides of the maxilla following random allocation. The primary outcome is placement accuracy assessed by three-dimensional positional and angular deviations between planned and actual miniscrew positions. Secondary outcomes include miniscrew stability, success rate after three months, postoperative pain, procedural time, patient satisfaction, and complications. The study also evaluates maxillary posterior cortical bone thickness using cone-beam computed tomography (CBCT) and investigates its relationship with miniscrew placement accuracy and stability

Panoramica dello studio

Descrizione dettagliata

Orthodontic miniscrews have become an effective source of temporary skeletal anchorage because they provide absolute anchorage with minimal dependence on patient compliance. However, the success of orthodontic miniscrews largely depends on accurate insertion while avoiding adjacent anatomical structures, particularly dental roots and the maxillary sinus. Incorrect placement may lead to root damage, instability, or failure of the miniscrew Cone-beam computed tomography (CBCT) allows three-dimensional evaluation of alveolar bone morphology and cortical bone thickness before miniscrew insertion. Digital technologies combining CBCT, intraoral scanning, CAD/CAM planning, and three-dimensional printing have enabled fabrication of customized surgical guides designed to improve insertion accuracy This study is designed as a randomized split-mouth controlled clinical trial. Patients requiring bilateral orthodontic miniscrews in the posterior maxilla will receive one miniscrew inserted using a CAD/CAM 3D-printed surgical guide and the contralateral miniscrew inserted using the conventional free-hand technique. The side allocated to each intervention and the order of insertion will be randomized Placement accuracy will be evaluated by superimposing preoperative planning data with postoperative digital models using Geomagic Studio software. Three-dimensional deviations, including coronal and apical positional deviations and angular deviations, will be calculated. Miniscrew stability, success rate after three months, postoperative pain measured by the Visual Analog Scale (VAS), patient satisfaction, operative time, and treatment-related complications will also be evaluated. Additionally, CBCT will be used to measure cortical bone thickness at multiple posterior maxillary interradicular sites, and correlations between cortical bone thickness and miniscrew accuracy and stability will be analyzed

Tipo di studio

Interventistico

Iscrizione (Effettivo)

33

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

      • Can Tho, Vietnam, +84
        • Can Tho University of Medicine and Pharmacy

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

  • Adulto
  • Adulto più anziano

Accetta volontari sani

Descrizione

Inclusion Criteria:

  • Adults aged 18 years or older.
  • Patients requiring bilateral orthodontic miniscrew placement in the posterior maxilla as part of orthodontic treatment.
  • Availability of high-quality cone-beam computed tomography (CBCT) images suitable for evaluation and digital planning.
  • Good general health and ability to undergo orthodontic treatment.
  • Healthy periodontal tissues at the planned miniscrew insertion sites.
  • Ability and willingness to provide written informed consent.

Exclusion Criteria:

  • Systemic diseases or medications affecting bone healing or bone metabolism.
  • Bleeding disorders or contraindications to minor oral surgery.
  • Active periodontal disease or local infection at the planned insertion site.
  • Poor-quality or incomplete CBCT images.
  • Contraindications to CBCT imaging.
  • Pregnancy or lactation.
  • Previous orthodontic miniscrew placement in the planned insertion area.
  • Refusal or inability to provide informed consent.

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione parallela
  • Mascheramento: Separare

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: CAD/CAM-Guided Miniscrew Placement
Miniscrew placement using a customized CAD/CAM 3D-printed surgical guide.
A customized tooth-supported CAD/CAM-designed and 3D-printed surgical guide fabricated from CBCT and intraoral scan data to assist accurate orthodontic miniscrew insertion in the posterior maxilla according to the preoperative digital treatment plan.
Comparatore attivo: Free-Hand Miniscrew Placement
Conventional free-hand orthodontic miniscrew placement.
Orthodontic miniscrews are inserted manually using the conventional free-hand technique without the assistance of a surgical guide, based on the clinician's clinical judgment and anatomical landmarks.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Accuracy of Orthodontic Miniscrew Placement
Lasso di tempo: Immediately after miniscrew placement
Placement accuracy will be assessed by comparing the planned and actual miniscrew positions using digital superimposition. Coronal and apical three-dimensional deviations together with angular deviations will be calculated using Geomagic Studio software.
Immediately after miniscrew placement

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Miniscrew Success Rate
Lasso di tempo: 3 months
Clinical success defined as stable miniscrews remaining functional for orthodontic anchorage.
3 months
Miniscrew Stability
Lasso di tempo: Immediately after insertion, 1 week, 1 month, and 3 months.
Clinical assessment of miniscrew stability after insertion.
Immediately after insertion, 1 week, 1 month, and 3 months.
Three-Dimensional Miniscrew Displacement
Lasso di tempo: 3 months.
Changes in miniscrew position between immediate postoperative and 3-month evaluations
3 months.

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Investigatori

  • Investigatore principale: Lam Nguyen Le, Assoc. Prof., Faculty of Odonto-Stomatology, Can Tho University of Medicine and Pharmacy

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

1 novembre 2025

Completamento primario (Effettivo)

1 giugno 2026

Completamento dello studio (Effettivo)

1 giugno 2026

Date di iscrizione allo studio

Primo inviato

7 luglio 2026

Primo inviato che soddisfa i criteri di controllo qualità

7 luglio 2026

Primo Inserito (Effettivo)

13 luglio 2026

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

13 luglio 2026

Ultimo aggiornamento inviato che soddisfa i criteri QC

7 luglio 2026

Ultimo verificato

1 luglio 2026

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • LeNguyenLam

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su CAD/CAM 3D-Printed Surgical Guide

3
Sottoscrivi