- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT07711613
Accuracy of AI Assisted Surgical Guide (AISG) (AISG)
Accuracy of AI-Assisted Static Surgical Guides in Delayed Dental Implant Placement in The Maxillary Esthetic Zone: A Randomized Controlled Trial
Aperçu de l'étude
Statut
Description détaillée
Wide research has been conducted to enhance the accuracy of implant placement within the bone while adopting more conservative techniques to improve overall success rates. The digital workflow for computer-aided implant surgery includes a range of steps leading to generation of a prosthetically driven, 3-dimensional virtual plan, and generation of static surgical guide. The use of AI integrated software decreases those steps drastically and seems to be a time saver. This study aims to evaluate and compare the accuracy of conventional static surgical guide and AI-assisted static surgical guide in implant placement in the esthetic zone of partially edentulous maxilla. This clinical study will be conducted on 20 surgical guides, divided equally and randomly via (www.randomizer.org) into 2 groups: Group 1: 10 implants will be placed using 10 conventional surgical guides which are made using traditional manual planning & designing (control group). Group 2: 10 implants will be placed using 10 AI-assisted surgical guides crafted with the help of machine learning-based planning software (study group). AI integrated software performs thorough analysis of the patient's anatomy & a personalized and precise approach of implant placement. By automating the planning process, AI-assisted guides help reduce human error, planning time and provide precise, data-driven recommendations for implant placement position.
Objectives of this study is
Radiographic assessment through:
- pre-operative CBCT & immediate postoperative CBCT to measure and compare angular and linear deviation, and implant depth between planned and actual implant positions in both groups.
6 months post operative CBCT for measuring marginal bone level
- peri implant bone density.
Clinical assessment through:
• Measuring implant stability quotient (ISQ) by Osstell ISQ Scale immediately and 6 months post operative.
Type d'étude
Inscription (Estimé)
Phase
- N'est pas applicable
Contacts et emplacements
Coordonnées de l'étude
- Nom: AlShaimaa Saeed, Bachelor (BDS)
- Numéro de téléphone: +20 115 4727016
- E-mail: alshaimaa_saeed@dent.suez.edu.eg
Lieux d'étude
-
-
-
Ismailia, Egypte
- Faculty of Dentistry, Suez Canal University
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
Accepte les volontaires sains
La description
Inclusion Criteria:
- 1- Missing teeth in esthetic zone of maxilla. 2-Both genders (male and female). 3- Adult ages (from 21 years to 60 years).
Exclusion Criteria:
- Medically compromised patient (uncontrolled diabetes, radiotherapy, chemotherapy and hemophilia). 2- Patient with oral habit as bruxism, heavy smoking. 3- Patient with bad oral hygiene. 4- Patient with severe gingival diseases. 5- Patient with severe periodontal diseases (with severe vertical or horizontal bone loss).
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: conventional static surgical guide
|
Conventional digitally planned surgical guide used for guided implant placement.
|
|
Comparateur actif: AI assisted static surgical guide
|
AI assisted surgical guide for guided placement of dental implants
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Higher accuracy of AI assisted surgical guide
Délai: Within 24 hours after implant placement
|
The deviation between the planned and the actual implant positions will be measured in three dimensions: 1) 2) Angular deviation calculated in degrees. Linear deviation at implant platform and implant apex in millimeters. 3) Implant depth in millimeters The less the deviation, the higher the accuracy |
Within 24 hours after implant placement
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Successful Osseointegration
Délai: 6 months postoperative follow up
|
Implant stability will be measured using an Osstell device (Implant Stability Quotient - ISQ). 6 months Post-operative CBCT for measuring marginal bone level & peri implant bone density.
|
6 months postoperative follow up
|
Collaborateurs et enquêteurs
Parrainer
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Estimé)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Autres numéros d'identification d'étude
- 1148
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Description du régime IPD
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .