- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT07730476
3D-Printed vs Conventional Fixed Retainers After Orthodontic Treatment
Comparison Between Three-Dimensionally Printed Fixed Retainers Versus Conventional Multistranded Stainless Steel Fixed Retainers: Randomized Clinical Trial
Aperçu de l'étude
Statut
Les conditions
Description détaillée
Orthodontic relapse remains one of the greatest challenges following the completion of orthodontic treatment. Conventional multistranded stainless steel fixed retainers are considered the gold standard for long-term retention; however, they have several limitations, including operator-dependent adaptation, prolonged chairside time, structural instability, and possible unwanted tooth movement.
Advances in digital dentistry have introduced CAD/CAM technology and additive manufacturing (3D printing), enabling the fabrication of customized fixed retainers with improved adaptation and manufacturing accuracy. Three-dimensional printed retainers fabricated from Cobalt-Chromium (Co-Cr) and Titanium Grade 5 (Ti-6Al-4V) alloys may provide superior mechanical properties, greater manufacturing precision, and potentially improved clinical performance compared with conventional retainers.
Type d'étude
Inscription (Estimé)
Phase
- N'est pas applicable
Contacts et emplacements
Coordonnées de l'étude
- Nom: Salma A Daabis, BDS
- Numéro de téléphone: +201066600270
- E-mail: salma.daabis@pua.edu.eg
Sauvegarde des contacts de l'étude
- Nom: Ahmed Sh Hashem, Professor
- Numéro de téléphone: +201002024437
- E-mail: ahmedshawkydent@yahoo.com
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
Accepte les volontaires sains
La description
Inclusion Criteria:
- Age range 21-35 years old after finishing orthodontic treatment.
- Presence of all maxillary and mandibular anterior teeth with normal shape and size.
- Completion of orthodontic treatment with full fixed appliances.
Exclusion Criteria:
- Patients with cleft lip and/or palate or any other craniofacial syndrome
- Patients with compromised oral hygiene or periodontal disease
- Patients who had orthognathic surgery
- Lingual appliance treatments
- Enamel hypoplasia, fluorosis, active caries, restorations, or fractures in the anterior teeth
- Patients who had separate arch debondings with a difference of more than 2 months in-between jaws
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: Conventional Stainless Steel Fixed Retainer
Participants receive a conventional multistranded stainless steel fixed retainer bonded after orthodontic debonding.
|
Conventional 0.0215-inch six-stranded stainless steel bonded fixed retainer.
|
|
Expérimental: 3D-Printed Cobalt-Chromium Fixed Retainer
Participants receive a customized 3D-printed cobalt-chromium fixed retainer bonded after orthodontic debonding
|
Customized 3D-printed cobalt-chromium bonded fixed retainer fabricated from intraoral scans.
|
|
Expérimental: 3D-Printed Titanium Fixed Retainer
Participants receive a customized 3D-printed titanium (Ti-6Al-4V) fixed retainer bonded after orthodontic debonding.
|
Customized 3D-printed titanium (Ti-6Al-4V) bonded fixed retainer fabricated from intraoral scans.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Orthodontic stability assessed using Little's Irregularity Index
Délai: 12 months
|
Orthodontic stability will be assessed using Little's Irregularity Index on digital models.
The Little's Irregularity Index ranges from 0 mm to higher positive values.
A score of 0 mm indicates perfect alignment.
Higher scores indicate greater relapse, whereas lower scores indicate better orthodontic stability.
|
12 months
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Retainer failure rate
Délai: 12 months
|
Assessment of the failure rate of conventional stainless steel, 3D-printed cobalt-chromium, and 3D-printed titanium fixed retainers.
|
12 months
|
|
Probing Pocket Depth (PPD)
Délai: 12 months
|
Assessment of periodontal pocket depth using a periodontal probe.
Pocket depth will be recorded in millimeters (mm).
Lower values indicate better periodontal health.
|
12 months
|
|
Plaque Index (Silness and Löe Plaque Index)
Délai: 12 months
|
Dental plaque accumulation will be assessed using the Silness and Löe Plaque Index, which is scored from 0 to 3: 0: No plaque
Lower scores indicate better oral hygiene. |
12 months
|
|
Gingival Index (Löe and Silness Gingival Index)
Délai: 12 months
|
Gingival inflammation will be assessed using the Löe and Silness Gingival Index, which is scored from 0 to 3: 0: Normal gingiva
Lower scores indicate better gingival health. |
12 months
|
|
Bleeding on Probing (BOP)
Délai: 12 months
|
Assessment of bleeding on probing as an indicator of gingival inflammation.
Bleeding on probing will be assessed as the percentage of bleeding sites (0-100%).
Lower percentages indicate better periodontal health.
|
12 months
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Salma A daabis, BDS, Minia University
- Chercheur principal: Ahmed Sh Hashem, Professor, Minia University
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Estimé)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- SDD-RCT-2026-01
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Description du régime IPD
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .