- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT07822425
A Study Of Augmented Reality Real-Time Guidance With In-situ Feedback
10 septembre 2026 mis à jour par: David Sella, Mayo Clinic
Augmented Reality Real-Time Guidance With In-situ Feedback
The purpose of this study is to evaluate the feasibility and safety of using the LUMENA guidance system during clinical procedures in patients undergoing CT-guided needle Placement for kidney, liver, lymph node, abdominal mass and lung ablation/biopsy.
Aperçu de l'étude
Statut
Recrutement
Intervention / Traitement
Type d'étude
Interventionnel
Inscription (Estimé)
10
Phase
- N'est pas applicable
Contacts et emplacements
Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.
Coordonnées de l'étude
- Nom: Julia Santos
- Numéro de téléphone: 904-953-3280
- E-mail: santos.julia@mayo.edu
Sauvegarde des contacts de l'étude
- Nom: Nic Dybel
- Numéro de téléphone: 904-953-4324
- E-mail: dybel.nicolas@mayo.edu
Lieux d'étude
-
-
Florida
-
Jacksonville, Florida, États-Unis, 32224
- Recrutement
- Mayo Clinic
-
Contact:
- Riley Nichols
- Numéro de téléphone: 904-953-7783
-
Chercheur principal:
- David Sella, MD
-
-
Critères de participation
Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
Oui
La description
INCLUSION CRITERIA
- Provision of signed and dated informed consent form
- Stated willingness to comply with all study procedures and availability for the duration of the study
- Male or female, ages 18-90 years
- Patient referred to Interventional Radiology for CT-guided needle placement for ablation/biopsy.
EXCLUSION CRITERIA
- Patients who are unable to give informed consent themselves or through their parents.
- Patients that do not fit into the gantry of the CT scanner.
- Patients who are sensitive to radiation exposure such as pregnant women.
Plan d'étude
Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Faisabilité de l'appareil
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: LUMENA Augmented Reality Guidance
Participants will undergo clinically indicated CT-guided needle placement for ablation or biopsy with use of the LUMENA augmented reality guidance system.
|
LUMENA is an augmented reality needle guidance system that provides real-time visual guidance during CT-guided needle placement procedures.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Feasibility of completing the CT-guided needle placement procedure using the LUMENA guidance system
Délai: 2 years
|
Feasibility will be assessed as the proportion of procedures successfully completed using the LUMENA guidance system without withdrawal of the system before completion.
The procedure will be considered feasible if more than 80% of procedures are completed using the system.
|
2 years
|
|
Safety of CT-guided needle placement using the LUMENA guidance system as assessed by adverse events
Délai: 2 years
|
Safety will be assessed by the occurrence of serious adverse events and total adverse events associated with the procedure.
The safety endpoint is safe needle placement in the target without any serious adverse events and total adverse events less than 10%.
|
2 years
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Accuracy of needle placement
Délai: 1 day
|
Needle placement accuracy will be assessed by comparing the planned target location on the planning CT image set with the actual needle tip location on the confirmatory CT image set.
Accuracy will be calculated as the three-dimensional distance between the planned target and actual needle tip location, reported in millimeters.
|
1 day
|
|
Procedure time
Délai: 1 day
|
Procedure time will be measured from acquisition of the initial imaging to acquisition of the final imaging and reported in minutes.
|
1 day
|
|
Number of intermediary CT/fluoroscopy images
Délai: 1 day
|
The number of intermediary CT/fluoroscopy images obtained during the procedure will be recorded as an indirect measure of radiation exposure.
|
1 day
|
|
Operator usability assessment of the LUMENA guidance system
Délai: 1 day
|
At the end of each procedure, the operator will complete a usability form that captures ease of use using a Likert scale and subjective clinical impressions of system use and utility.
|
1 day
|
Collaborateurs et enquêteurs
C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.
Parrainer
Les enquêteurs
- Chercheur principal: David Sella, MD, Mayo Clinic
Dates d'enregistrement des études
Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.
Dates principales de l'étude
Début de l'étude (Estimé)
17 septembre 2026
Achèvement primaire (Estimé)
16 septembre 2028
Achèvement de l'étude (Estimé)
16 septembre 2028
Dates d'inscription aux études
Première soumission
10 septembre 2026
Première soumission répondant aux critères de contrôle qualité
10 septembre 2026
Première publication (Réel)
16 septembre 2026
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
16 septembre 2026
Dernière mise à jour soumise répondant aux critères de contrôle qualité
10 septembre 2026
Dernière vérification
1 septembre 2026
Plus d'information
Termes liés à cette étude
Autres numéros d'identification d'étude
- 26-002714
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
NON
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Non
Étudie un produit d'appareil réglementé par la FDA américaine
Oui
produit fabriqué et exporté des États-Unis.
Oui
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .