- ICH GCP
- USA klinikai vizsgálatok nyilvántartása
- Klinikai vizsgálat NCT02500160
Comparative Study of Total Knee Arthroplasty Using a Customized-patient Specific Instrument System.
2015. július 14. frissítette: KANG-IL KIM, Kyung Hee University Hospital at Gangdong
Patient-specific instrumentation (PSI) has been introduced in total knee arthroplasty (TKA) as a new technology for improving accuracy in restoration of the alignment and biomechanics of the lower limb.
PSI in TKA refers to custom-made cutting jigs manufactured according to the patient's anatomic configuration of distal femur and proximal tibia based on preoperative magnetic resonance imaging (MRI) or computed tomography (CT) scans.
MRI- and CT-based PSI systems are available from various manufacturers for preoperative planning.
MRI offers precise visualization of articular cartilage without the risk of radiation exposure, but it is expensive and requires long scan times.
In contrast, CT enables accurate identification of the contour of the femur and tibia at short scan times, but it does not provide information on the cartilage thickness and carries the risk of radiation exposure.
As a result, there is a possibility of some discrepancy between the thickness of bone resection proposed by MRI- or CT-based PSI system and the actual thickness of bone cut.
Although PSI has been the focus of study in many recent researches, there has been no clinical study comparing MRI-based and CT-based PSI systems in preoperative planning.
Therefore the investigators questioned whether the MRI-based PSI that reflects the cartilage layer would provide more precision in TKA than the CT-based PSI.
The purpose of this study was to investigate the accuracy of MRI-based PSI and CT-based PSI in predicting bone resection thickness in TKA.
A tanulmány áttekintése
Állapot
Ismeretlen
Körülmények
Beavatkozás / kezelés
Tanulmány típusa
Beavatkozó
Beiratkozás (Tényleges)
80
Fázis
- Nem alkalmazható
Kapcsolatok és helyek
Ez a rész a vizsgálatot végzők elérhetőségeit, valamint a vizsgálat lefolytatásának helyére vonatkozó információkat tartalmazza.
Tanulmányi helyek
-
-
-
Seoul, Koreai Köztársaság, 134-090
- Kyung Hee University Hospital at Gangdong
-
-
Részvételi kritériumok
A kutatók olyan embereket keresnek, akik megfelelnek egy bizonyos leírásnak, az úgynevezett jogosultsági kritériumoknak. Néhány példa ezekre a kritériumokra a személy általános egészségi állapota vagy a korábbi kezelések.
Jogosultsági kritériumok
Tanulmányozható életkorok
- Gyermek
- Felnőtt
- Idősebb felnőtt
Egészséges önkénteseket fogad
Igen
Tanulmányozható nemek
Összes
Leírás
Inclusion Criteria:
- Of the patients who had been scheduled for TKA for the treatment of primary osteoarthritis only with varus deformity, those who had been waiting 6 weeks for TKA using an MRI-based or CT-based PSI system and had consented to the relatively new technique were enrolled in the study.
Exclusion Criteria:
- Patients with primary osteoarthritis with valgus deformity, rheumatoid arthritis, hemophilic arthritis, posttraumatic arthritis, other inflammatory arthritis, or a history of previous high tibial osteotomy were excluded from the study.
Tanulási terv
Ez a rész a vizsgálati terv részleteit tartalmazza, beleértve a vizsgálat megtervezését és a vizsgálat mérését.
Hogyan készül a tanulmány?
Tervezési részletek
- Elsődleges cél: Kezelés
- Kiosztás: Véletlenszerűsített
- Beavatkozó modell: Párhuzamos hozzárendelés
- Maszkolás: Egyetlen
Fegyverek és beavatkozások
Résztvevő csoport / kar |
Beavatkozás / kezelés |
|---|---|
|
Kísérleti: patient specific instrumentation (MRI)
MRI based patient-specific instrumentation
|
|
|
Aktív összehasonlító: patient specific instrumentation (CT)
CT based patient-specific instrumentation
|
Mit mér a tanulmány?
Elsődleges eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
The absolute differences (mm) between the planned resection thickness and the actual resection thickness in the femur and the tibia.
Időkeret: intraoperative time
|
After bone resection using a patient-specific cutting jig, the actual thickness of resected bone was measured in 0.1 mm increments by the Vernier caliper (B.Braun-Aesculap, Tuttlingen, Germany) and compared with the planned resection thickness preoperatively using the PSI program.In the MRI group, the intraoperative cutting thickness was compared directly with the preoperatively planned thickness, whereas the presumed thickness of cartilage (2 mm) was added to actual thickness of resected bone from the lateral condyles in the CT group.
Finally, the thickness of saw blade (1.27-mm) was added to every resected bone in all cases.
|
intraoperative time
|
Másodlagos eredményintézkedések
Eredménymérő |
Intézkedés leírása |
Időkeret |
|---|---|---|
|
radiographic assessment
Időkeret: postoperative 6 weeks
|
The mechanical axis (MA) of the lower extremity and the coronal and sagittal alignments of the femoral and tibial components were measured on the anterior and lateral weight-bearing radiographs of the knee and the lower extremity orthogram before the surgery and 6 weeks after the surgery.
The measurements were performed using a picture-acquiring communication system (PACS, Infinitt Healthcare, Seoul, Korea), and the data were recorded to one decimal place.
|
postoperative 6 weeks
|
Együttműködők és nyomozók
Itt találhatja meg a tanulmányban érintett személyeket és szervezeteket.
Nyomozók
- Kutatásvezető: Kang-Il Kim, MD,PhD, Kyung Hee University Hospital at Gangdong
Tanulmányi rekorddátumok
Ezek a dátumok nyomon követik a ClinicalTrials.gov webhelyre benyújtott vizsgálati rekordok és összefoglaló eredmények benyújtásának folyamatát. A vizsgálati feljegyzéseket és a jelentett eredményeket a Nemzeti Orvostudományi Könyvtár (NLM) felülvizsgálja, hogy megbizonyosodjon arról, hogy megfelelnek-e az adott minőség-ellenőrzési szabványoknak, mielőtt közzéteszik őket a nyilvános weboldalon.
Tanulmány főbb dátumok
Tanulmány kezdete
2011. február 1.
Elsődleges befejezés (Tényleges)
2012. szeptember 1.
Tanulmányi regisztráció dátumai
Először benyújtva
2015. július 13.
Először nyújtották be, amely megfelel a minőségbiztosítási kritériumoknak
2015. július 14.
Első közzététel (Becslés)
2015. július 16.
Tanulmányi rekordok frissítései
Utolsó frissítés közzétéve (Becslés)
2015. július 16.
Az utolsó frissítés elküldve, amely megfelel a minőségbiztosítási kritériumoknak
2015. július 14.
Utolsó ellenőrzés
2015. július 1.
Több információ
A tanulmányhoz kapcsolódó kifejezések
További vonatkozó MeSH feltételek
Egyéb vizsgálati azonosító számok
- KHNMC 2011-058
Ezt az információt közvetlenül a clinicaltrials.gov webhelyről szereztük be, változtatás nélkül. Ha bármilyen kérése van vizsgálati adatainak módosítására, eltávolítására vagy frissítésére, kérjük, írjon a következő címre: register@clinicaltrials.gov. Amint a változás bevezetésre kerül a clinicaltrials.gov oldalon, ez a webhelyünkön is automatikusan frissül. .