Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Comparative Study of Total Knee Arthroplasty Using a Customized-patient Specific Instrument System.

14 juillet 2015 mis à jour par: KANG-IL KIM, Kyung Hee University Hospital at Gangdong
Patient-specific instrumentation (PSI) has been introduced in total knee arthroplasty (TKA) as a new technology for improving accuracy in restoration of the alignment and biomechanics of the lower limb. PSI in TKA refers to custom-made cutting jigs manufactured according to the patient's anatomic configuration of distal femur and proximal tibia based on preoperative magnetic resonance imaging (MRI) or computed tomography (CT) scans. MRI- and CT-based PSI systems are available from various manufacturers for preoperative planning. MRI offers precise visualization of articular cartilage without the risk of radiation exposure, but it is expensive and requires long scan times. In contrast, CT enables accurate identification of the contour of the femur and tibia at short scan times, but it does not provide information on the cartilage thickness and carries the risk of radiation exposure. As a result, there is a possibility of some discrepancy between the thickness of bone resection proposed by MRI- or CT-based PSI system and the actual thickness of bone cut. Although PSI has been the focus of study in many recent researches, there has been no clinical study comparing MRI-based and CT-based PSI systems in preoperative planning. Therefore the investigators questioned whether the MRI-based PSI that reflects the cartilage layer would provide more precision in TKA than the CT-based PSI. The purpose of this study was to investigate the accuracy of MRI-based PSI and CT-based PSI in predicting bone resection thickness in TKA.

Aperçu de l'étude

Type d'étude

Interventionnel

Inscription (Réel)

80

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Enfant
  • Adulte
  • Adulte plus âgé

Accepte les volontaires sains

Oui

Sexes éligibles pour l'étude

Tout

La description

Inclusion Criteria:

  • Of the patients who had been scheduled for TKA for the treatment of primary osteoarthritis only with varus deformity, those who had been waiting 6 weeks for TKA using an MRI-based or CT-based PSI system and had consented to the relatively new technique were enrolled in the study.

Exclusion Criteria:

  • Patients with primary osteoarthritis with valgus deformity, rheumatoid arthritis, hemophilic arthritis, posttraumatic arthritis, other inflammatory arthritis, or a history of previous high tibial osteotomy were excluded from the study.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Seul

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: patient specific instrumentation (MRI)
MRI based patient-specific instrumentation
Comparateur actif: patient specific instrumentation (CT)
CT based patient-specific instrumentation

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
The absolute differences (mm) between the planned resection thickness and the actual resection thickness in the femur and the tibia.
Délai: intraoperative time
After bone resection using a patient-specific cutting jig, the actual thickness of resected bone was measured in 0.1 mm increments by the Vernier caliper (B.Braun-Aesculap, Tuttlingen, Germany) and compared with the planned resection thickness preoperatively using the PSI program.In the MRI group, the intraoperative cutting thickness was compared directly with the preoperatively planned thickness, whereas the presumed thickness of cartilage (2 mm) was added to actual thickness of resected bone from the lateral condyles in the CT group. Finally, the thickness of saw blade (1.27-mm) was added to every resected bone in all cases.
intraoperative time

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
radiographic assessment
Délai: postoperative 6 weeks
The mechanical axis (MA) of the lower extremity and the coronal and sagittal alignments of the femoral and tibial components were measured on the anterior and lateral weight-bearing radiographs of the knee and the lower extremity orthogram before the surgery and 6 weeks after the surgery. The measurements were performed using a picture-acquiring communication system (PACS, Infinitt Healthcare, Seoul, Korea), and the data were recorded to one decimal place.
postoperative 6 weeks

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Les enquêteurs

  • Chercheur principal: Kang-Il Kim, MD,PhD, Kyung Hee University Hospital at Gangdong

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude

1 février 2011

Achèvement primaire (Réel)

1 septembre 2012

Dates d'inscription aux études

Première soumission

13 juillet 2015

Première soumission répondant aux critères de contrôle qualité

14 juillet 2015

Première publication (Estimation)

16 juillet 2015

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Estimation)

16 juillet 2015

Dernière mise à jour soumise répondant aux critères de contrôle qualité

14 juillet 2015

Dernière vérification

1 juillet 2015

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • KHNMC 2011-058

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

Essais cliniques sur Patient specific instrumentation (MRI)

3
S'abonner