- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT02500160
Comparative Study of Total Knee Arthroplasty Using a Customized-patient Specific Instrument System.
14 juillet 2015 mis à jour par: KANG-IL KIM, Kyung Hee University Hospital at Gangdong
Patient-specific instrumentation (PSI) has been introduced in total knee arthroplasty (TKA) as a new technology for improving accuracy in restoration of the alignment and biomechanics of the lower limb.
PSI in TKA refers to custom-made cutting jigs manufactured according to the patient's anatomic configuration of distal femur and proximal tibia based on preoperative magnetic resonance imaging (MRI) or computed tomography (CT) scans.
MRI- and CT-based PSI systems are available from various manufacturers for preoperative planning.
MRI offers precise visualization of articular cartilage without the risk of radiation exposure, but it is expensive and requires long scan times.
In contrast, CT enables accurate identification of the contour of the femur and tibia at short scan times, but it does not provide information on the cartilage thickness and carries the risk of radiation exposure.
As a result, there is a possibility of some discrepancy between the thickness of bone resection proposed by MRI- or CT-based PSI system and the actual thickness of bone cut.
Although PSI has been the focus of study in many recent researches, there has been no clinical study comparing MRI-based and CT-based PSI systems in preoperative planning.
Therefore the investigators questioned whether the MRI-based PSI that reflects the cartilage layer would provide more precision in TKA than the CT-based PSI.
The purpose of this study was to investigate the accuracy of MRI-based PSI and CT-based PSI in predicting bone resection thickness in TKA.
Aperçu de l'étude
Statut
Inconnue
Les conditions
Intervention / Traitement
Type d'étude
Interventionnel
Inscription (Réel)
80
Phase
- N'est pas applicable
Contacts et emplacements
Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.
Lieux d'étude
-
-
-
Seoul, Corée, République de, 134-090
- Kyung Hee University Hospital at Gangdong
-
-
Critères de participation
Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.
Critère d'éligibilité
Âges éligibles pour étudier
- Enfant
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
Oui
Sexes éligibles pour l'étude
Tout
La description
Inclusion Criteria:
- Of the patients who had been scheduled for TKA for the treatment of primary osteoarthritis only with varus deformity, those who had been waiting 6 weeks for TKA using an MRI-based or CT-based PSI system and had consented to the relatively new technique were enrolled in the study.
Exclusion Criteria:
- Patients with primary osteoarthritis with valgus deformity, rheumatoid arthritis, hemophilic arthritis, posttraumatic arthritis, other inflammatory arthritis, or a history of previous high tibial osteotomy were excluded from the study.
Plan d'étude
Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Traitement
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Seul
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
---|---|
Expérimental: patient specific instrumentation (MRI)
MRI based patient-specific instrumentation
|
|
Comparateur actif: patient specific instrumentation (CT)
CT based patient-specific instrumentation
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
---|---|---|
The absolute differences (mm) between the planned resection thickness and the actual resection thickness in the femur and the tibia.
Délai: intraoperative time
|
After bone resection using a patient-specific cutting jig, the actual thickness of resected bone was measured in 0.1 mm increments by the Vernier caliper (B.Braun-Aesculap, Tuttlingen, Germany) and compared with the planned resection thickness preoperatively using the PSI program.In the MRI group, the intraoperative cutting thickness was compared directly with the preoperatively planned thickness, whereas the presumed thickness of cartilage (2 mm) was added to actual thickness of resected bone from the lateral condyles in the CT group.
Finally, the thickness of saw blade (1.27-mm) was added to every resected bone in all cases.
|
intraoperative time
|
Mesures de résultats secondaires
Mesure des résultats |
Description de la mesure |
Délai |
---|---|---|
radiographic assessment
Délai: postoperative 6 weeks
|
The mechanical axis (MA) of the lower extremity and the coronal and sagittal alignments of the femoral and tibial components were measured on the anterior and lateral weight-bearing radiographs of the knee and the lower extremity orthogram before the surgery and 6 weeks after the surgery.
The measurements were performed using a picture-acquiring communication system (PACS, Infinitt Healthcare, Seoul, Korea), and the data were recorded to one decimal place.
|
postoperative 6 weeks
|
Collaborateurs et enquêteurs
C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.
Les enquêteurs
- Chercheur principal: Kang-Il Kim, MD,PhD, Kyung Hee University Hospital at Gangdong
Dates d'enregistrement des études
Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.
Dates principales de l'étude
Début de l'étude
1 février 2011
Achèvement primaire (Réel)
1 septembre 2012
Dates d'inscription aux études
Première soumission
13 juillet 2015
Première soumission répondant aux critères de contrôle qualité
14 juillet 2015
Première publication (Estimation)
16 juillet 2015
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Estimation)
16 juillet 2015
Dernière mise à jour soumise répondant aux critères de contrôle qualité
14 juillet 2015
Dernière vérification
1 juillet 2015
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- KHNMC 2011-058
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .
Essais cliniques sur Patient specific instrumentation (MRI)
-
October 6 UniversityComplété
-
Nantes University HospitalComplété
-
National Institute of Medical Sciences and Nutrition...RecrutementQualité de vie | Maladies rhumatismales | Dignité | Détresse, ÉmotionnelleMexique
-
Region StockholmKarolinska Institutet; Linkoeping University; Stockholm UniversityRecrutementGrossesse | Soins de santé primaires | Jeunesse | Violence interpersonnelleSuède
-
Freeman-Sheldon Research Group, Inc.RésiliéAnomalies craniofaciales | Arthrogrypose | Syndrome de Freeman-Sheldon | Arthrogrypose distale de type 2A | Syndrome du visage sifflant | Dysplasie craniocarpotarsienne | Dystrophie craniocarpotarsienne | Variante du syndrome de Freeman-Sheldon | Syndrome de Sheldon Hall | Arthrogrypose distale de type... et d'autres conditionsÉtats-Unis