- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT01974908
Fibrillatory Factor in Ventricular Tachycardia
Using Fibrillatory Factor to Predict the Source of Ventricular Tachycardia in Man
This study involves recording electrical signals inside the heart during an ablation procedure. It is thought that by studying these electrical signals in detail the investigators may be able to better identify and treat patients at risk of Ventricular Tachycardia (VT).
VT is where the lower chambers (ventricles) of your heart beat fast and this condition can be life-threatening. An ablation procedure is performed in patients who have VT despite the best treatment available with tablets.
Cardiac ablation involves interrupting the abnormal electrical signals, which cause VT, by applying a type of electrical energy through a catheter. An important part of the ablation procedure is the identification of the exact part of the heart muscle responsible for causing the VT. This typically involves sampling the electrical signals in lots of different areas of the heart, which allows the construction of computer generated 3 dimensional pictures of the structure and the electrical circuits inside the ventricle. Recent research has identified a new method to interpret these electrical signals (called Fibrillatory Factor - FF), which may allow better identification of the area within the ventricle that should be ablated.
A standard VT ablation will often involve us controlling the heart-beat by pacing the heart through 1 of the investigators catheters within the heart. The electrical response to pacing at different heart rates can often provide your doctor with information to help the ablation. This study will involve an additional period of pacing at different heart rates, during which the electrical response is measured in different areas around the ventricle. This will allow us to calculate areas of the ventricle, which the investigators new measure FF would predict to be the source of the VT. In the future this may then allow us to better identify patients who are at risk of VT, and to better locate the area that needs to be ablated.
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Tipo di studio
Iscrizione (Anticipato)
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
-
London, Regno Unito, SE1 7EH
- Guys and St Thomas' NHS Trust
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Age 18 or above, and capable of giving informed consent
- Scheduled for a clinically indicated cardiac ablation for the treatment of ventricular tachycardia
Exclusion Criteria:
- Moderate or severe aortic stenosis or mitral stenosis
- Active infection
- Presence of thrombus, cardiac tumour, interatrial Baffle patch (a specific form of congenital cardiac surgery) or prior septal occluder device
- Subjects who cannot be anticoagulated of infused with heparinized saline
- A history of heparin induced thrombocytopenia
- Pregnant or actively breast feeding
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Diagnostico
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: Ventricular Tachycardia (VT)
Patients with VT will undergo a clinically indicated ablation of their VT
|
During sinus rhythm these patients will undergo a simple pacing protocol to allow us to calculate FF, which is an area we would predict is mod likely to be the origin of their VT.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Fibrillatory Factor
Lasso di tempo: 18 months
|
To identify the proportion of clinical VT circuits which could be predicted during sinus rhythm from the calculation of fibrillation factor.
The number of FF derived VT exit points which are successfully predicted blindly by the investigators (using the clinically derived VT exit point based on electrophysiology assessment and ablation) will be the primary endpoint.
|
18 months
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Real-time fibrillatory factor
Lasso di tempo: 18 months
|
Having established that fibrillatory factor (FF) can predict VT circuits we will then develop our software further so that we can calculate FF in real-time.
This will then be used in further research studies to guide invasive mapping.
|
18 months
|
Collaboratori e investigatori
Investigatori
- Investigatore principale: Jaswinder Gill, MD, Guy's and St Thomas' NHS Trust
Studiare le date dei record
Studia le date principali
Inizio studio
Completamento primario (Anticipato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Stima)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- GSTT-FF-1
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .