- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT03757507
Investigation of Plaque Instability Using Bevacizumab-800CW and MSOT (Carotid)
Investigation of Plaque Instability: Identification of Atherosclerotic Plaque Angiogenesis Using Bevacizumab-800CW and Optoacoustic Imaging: a Single Center Proof of Concept Study (CAROTID-OPTOLIGHT)
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
Rationale: This project consists of the realization followed by the clinical validation of a procedure dedicated to detect vulnerable atherosclerotic plaques patients with a symptomatic carotid stenosis. If in the future it would be possible to detect a symptomatic carotid atherosclerotic plaque non- invasively (i.e. those plaques resulting in cerebrovascular accidents and/or transient ischemic attacks), this would strongly improve risk assessment among this large cohort of patients. At the moment, indications for intervention are primarily based on degree of stenosis, and not on degree of vulnerability. Symptomatology is considered, but clinicians are not capable of predicting the consequences of a first event, while two thirds of all patients with a major stroke are not preceded by previous minor symptoms. Previous trials (NASCET and ECST) showed a significant absolute risk reduction for symptomatic patients with a stenotic lesion of the internal carotid artery greater than 70% after the performance of a carotid endarterectomy (CEA; excision of the atherosclerotic plaque). However, surgery can be associated with significant morbidity and even mortality. On the other hand, reliable prediction prior to surgery whether an atherosclerotic plaque is going to become symptomatic could also prevent unnecessary surgery, which again significantly reduces morbidity and mortality.
In literature and our preliminary ex vivo data with a nuclear imaging tracer 89Zr-Bevacizumab, it appears that vulnerable atherosclerotic plaques (i.e. those likely to become symptomatic) have an increased rate of angiogenesis at the site of the rupture (i.e. the site of the vulnerable plaque) which expose highly upregulated Vascular Endothelial Growth Factor-A (VEGF-A) production as part of the inflammatory response within the plaque and subsequently which can be visualized with a tracer targeting specifically VEGF-A. Recently, these experiments have been repeated using Bevacizumab- CW800 showing similar results (Huisman et al, preliminary data).
An intraoperative near-infrared fluorescence (NIRF) imaging camera, among a NIR fluorescence endoscopy system, and the use of the optical contrast agent Bevacizumab-800CW in now more than 250 patients has been evaluated for its feasibility to detect tumor lesions in patients with colorectal cancer, colon polyps, Barret's esophagus, peritoneal carcinomatosis of colorectal cancer origin and breast cancer. These studies showed that bevacizumab-800CW is safe in clinical use and feasible to detect even small tumor lesions with a high sensitivity. While Bevacizumab-800CW can also detect the soluble ligand VEGF-A, as shown by ex vivo analyses of excised CEA specimen, we aim to investigate whether systemic administered Bevacizumab-800CW can be applied to patients preoperatively for the detection of vulnerable plaques by non-invasive optoacoustic imaging and subsequently ex vivo mesoscopic imaging for validation purposes. The primary objective for the proposed study is to achieve pre-operative detection of the atherosclerotic plaque for patients with a symptomatic carotid artery stenosis by non-invasive optoacoustic imaging. In this study we will introduce the following concept: a preoperative non-invasive optoacoustic-scan guided by the © UMCG october 2018 Version 2.0 7 of 40
Bevacizumab-800CW targeted VEGF-A. This will help us to detect if and at what time point within the atherosclerotic plaque there is an upregulation of angiogenesis which can cross-correlated by ex vivo analyses of characteristics of the vulnerable plaque (i.e. atheroma, foam cells, influx of activated macrophages and angiogenesis as a result of pro-inflammatory responses present in the plaque). The end-goal of the proposed dual pre- and intra-operative imaging procedure is to prove that the symptomatic carotid atherosclerotic plaque can be accurately and safely detected by VEGF-A targeted optical imaging agents. In addition, this study serves as a step-up to a larger non-invasive VEGF-A targeted optical imaging study expanding the detection technology by using a new non- invasive multispectral optoacoustic detection system. Ultimately, VEGF-A targeted imaging in carotid stenosis could be used to predict vulnerability of the atherosclerotic plaque non-invasively in order to select those patients who will benefit the most of a surgical procedure.
Objective:
This feasibility study has two objectives:
- To investigate whether it's feasible to detect plaques within the carotid artery using optoacoustic imaging with the innovative MSOT Acuity Echo in patients with symptomatic carotid stenosis.
- To investigate whether the VEGF-targeted optical imaging agent Bevacizumab-800CW is able to detect VEGF upregulation as a characteristic of the vulnerable plaque in carotid tissue by means of pre-operative Bevacizumab-800CW optoacoustic imaging in patients with symptomatic carotid stenosis cross-correlated by ex vivo histopathological analyses.
Study design: Interventional phase 1 technical feasibility study: non-randomized, open label, uncontrolled with single group proof of concept study. This study will be carried out at the University Medical Center Groningen, Department of Surgery and Department of Nuclear Medicine and Molecular Imaging. Further analysis of sections of the plaques will be done at the Department of Pathology at the UMCG and by the Helmholtz Institute, Biomedical Research Centre, München.
Study population: Patients planned for elective endarterectomy for symptomatic carotid stenosis will undergo prior to surgery imaging with an optoacoustic device before and after intravenous injection with the VEGF-targeted optical imaging agent Bevacizumab-800CW.
Intervention: Patients planned to undergo endarterectomy for symptomatic carotid stenosis will be consented for this study. The procedure will in no way delay the time interval between onset of symptoms and intervention. Three days before the planned fluorescent optoacoustic scanning, the patients will undergo optoacoustic imaging as a reference. Patients then receive an intravenous injection of 4,5 mg flat-dose of Bevacizumab-800CW. Three days after tracer administration, mostly
© UMCG october 2018 Version 2.0 8 of 40
the day patients are admitted to the hospital as standard-of-care, patients will undergo final optoacoustic imaging.
Main study parameters/endpoints:
Primary Objective:
- Feasibility of optoacoustic imaging to image the carotid artery and detect plaque formation in patients with symptomatic carotid artery disease.
- Pre-operative detection of the atherosclerotic plaque in symptomatic carotid stenosis by the VEGF-targeted optical imaging agent optical imaging agent Bevacizumab-800CW using optoacoustic imaging subsequently correlated ex vivo for VEGF upregulation within the plaque indicative for increased angiogenesis.
Tipo di studio
Iscrizione (Anticipato)
Fase
- Non applicabile
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
Patients above the age of 21 with an indication to undergo a carotid endarterectomy for suspected symptomatic atherosclerotic plaque based on the presence of a CVA and/or transient ischemic attacks (TIA's), including amourosis fugax.
- Patients with significant and symptomatic carotid stenosis who are scheduled for carotid endarterectomy as decided by the surgeon or the Multi-Disciplinary Carotid Board
Exclusion Criteria:
- Medical or psychiatric condition that compromises the patient's ability to give informed consent
- Pregnant or lactating women
- Significantrenal(creatinine>110μmol/L)dysfunction
- History of iodine allergy or anaphylactic reactions to insect bites or medication or previous allergic reaction to bevacizumab
- Presence or history of hyperthyroidism
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Fattibilità del dispositivo
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: Optoacoustic imaging
Optoacoustic Imaging before and after tracer administration
|
Multispectral Optoacoustic Tomography is a new emerging imaging technique which uses laser light to heat up molecules with a high pulsed laser.
The molecules undergo thermal expansion and produces sound waves, which can be detected by special transducers.
The device can pick up different signals in different wavelength to produce images with anatomic and biological information.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Feasibility of MSOT imaging
Lasso di tempo: 12 months
|
Feasibility of optoacoustic imaging to image the carotid artery and detect plaque formation in patients with symptomatic carotid artery disease.
|
12 months
|
|
Ex vivo imaging
Lasso di tempo: 12 months
|
Pre-operative detection of the atherosclerotic plaque in symptomatic carotid stenosis by the VEGF-targeted optical imaging agent optical imaging agent Bevacizumab-800CW using optoacoustic imaging subsequently correlated ex vivo for VEGF upregulation within the plaque indicative for increased angiogenesis.
|
12 months
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Location of Fluorescence
Lasso di tempo: 12 months
|
Presence of fluorescent signaling after excision of the atherosclerotic plaque ex vivo as determined by flatbed scanning and fluorescence microscopy.
|
12 months
|
Collaboratori e investigatori
Sponsor
Studiare le date dei record
Studia le date principali
Inizio studio (Anticipato)
Completamento primario (Anticipato)
Completamento dello studio (Anticipato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- 201800515
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .
Prove cliniche su MultiSpectral Optoacoustic Tomography
-
Istituto Ortopedico RizzoliCompletatoDislocazione femoro-rotuleaItalia
-
Medical University of ViennaReclutamento
-
National Cancer Institute (NCI)Attivo, non reclutanteLinfoma da versamento primario | Neoplasia a cellule BStati Uniti