Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Investigation of Plaque Instability Using Bevacizumab-800CW and MSOT (Carotid)

10 avril 2019 mis à jour par: G.M. van Dam

Investigation of Plaque Instability: Identification of Atherosclerotic Plaque Angiogenesis Using Bevacizumab-800CW and Optoacoustic Imaging: a Single Center Proof of Concept Study (CAROTID-OPTOLIGHT)

Determining whether we could visualize uptake of the fluorescent tracer Bevacizumab-800CW, targeting VEGF-A in atherosclerotic plaques by using the new imaging technique Multispectral Optoacoustic Tomography both in- and ex vivo.

Aperçu de l'étude

Description détaillée

Rationale: This project consists of the realization followed by the clinical validation of a procedure dedicated to detect vulnerable atherosclerotic plaques patients with a symptomatic carotid stenosis. If in the future it would be possible to detect a symptomatic carotid atherosclerotic plaque non- invasively (i.e. those plaques resulting in cerebrovascular accidents and/or transient ischemic attacks), this would strongly improve risk assessment among this large cohort of patients. At the moment, indications for intervention are primarily based on degree of stenosis, and not on degree of vulnerability. Symptomatology is considered, but clinicians are not capable of predicting the consequences of a first event, while two thirds of all patients with a major stroke are not preceded by previous minor symptoms. Previous trials (NASCET and ECST) showed a significant absolute risk reduction for symptomatic patients with a stenotic lesion of the internal carotid artery greater than 70% after the performance of a carotid endarterectomy (CEA; excision of the atherosclerotic plaque). However, surgery can be associated with significant morbidity and even mortality. On the other hand, reliable prediction prior to surgery whether an atherosclerotic plaque is going to become symptomatic could also prevent unnecessary surgery, which again significantly reduces morbidity and mortality.

In literature and our preliminary ex vivo data with a nuclear imaging tracer 89Zr-Bevacizumab, it appears that vulnerable atherosclerotic plaques (i.e. those likely to become symptomatic) have an increased rate of angiogenesis at the site of the rupture (i.e. the site of the vulnerable plaque) which expose highly upregulated Vascular Endothelial Growth Factor-A (VEGF-A) production as part of the inflammatory response within the plaque and subsequently which can be visualized with a tracer targeting specifically VEGF-A. Recently, these experiments have been repeated using Bevacizumab- CW800 showing similar results (Huisman et al, preliminary data).

An intraoperative near-infrared fluorescence (NIRF) imaging camera, among a NIR fluorescence endoscopy system, and the use of the optical contrast agent Bevacizumab-800CW in now more than 250 patients has been evaluated for its feasibility to detect tumor lesions in patients with colorectal cancer, colon polyps, Barret's esophagus, peritoneal carcinomatosis of colorectal cancer origin and breast cancer. These studies showed that bevacizumab-800CW is safe in clinical use and feasible to detect even small tumor lesions with a high sensitivity. While Bevacizumab-800CW can also detect the soluble ligand VEGF-A, as shown by ex vivo analyses of excised CEA specimen, we aim to investigate whether systemic administered Bevacizumab-800CW can be applied to patients preoperatively for the detection of vulnerable plaques by non-invasive optoacoustic imaging and subsequently ex vivo mesoscopic imaging for validation purposes. The primary objective for the proposed study is to achieve pre-operative detection of the atherosclerotic plaque for patients with a symptomatic carotid artery stenosis by non-invasive optoacoustic imaging. In this study we will introduce the following concept: a preoperative non-invasive optoacoustic-scan guided by the © UMCG october 2018 Version 2.0 7 of 40

Bevacizumab-800CW targeted VEGF-A. This will help us to detect if and at what time point within the atherosclerotic plaque there is an upregulation of angiogenesis which can cross-correlated by ex vivo analyses of characteristics of the vulnerable plaque (i.e. atheroma, foam cells, influx of activated macrophages and angiogenesis as a result of pro-inflammatory responses present in the plaque). The end-goal of the proposed dual pre- and intra-operative imaging procedure is to prove that the symptomatic carotid atherosclerotic plaque can be accurately and safely detected by VEGF-A targeted optical imaging agents. In addition, this study serves as a step-up to a larger non-invasive VEGF-A targeted optical imaging study expanding the detection technology by using a new non- invasive multispectral optoacoustic detection system. Ultimately, VEGF-A targeted imaging in carotid stenosis could be used to predict vulnerability of the atherosclerotic plaque non-invasively in order to select those patients who will benefit the most of a surgical procedure.

Objective:

This feasibility study has two objectives:

  • To investigate whether it's feasible to detect plaques within the carotid artery using optoacoustic imaging with the innovative MSOT Acuity Echo in patients with symptomatic carotid stenosis.
  • To investigate whether the VEGF-targeted optical imaging agent Bevacizumab-800CW is able to detect VEGF upregulation as a characteristic of the vulnerable plaque in carotid tissue by means of pre-operative Bevacizumab-800CW optoacoustic imaging in patients with symptomatic carotid stenosis cross-correlated by ex vivo histopathological analyses.

Study design: Interventional phase 1 technical feasibility study: non-randomized, open label, uncontrolled with single group proof of concept study. This study will be carried out at the University Medical Center Groningen, Department of Surgery and Department of Nuclear Medicine and Molecular Imaging. Further analysis of sections of the plaques will be done at the Department of Pathology at the UMCG and by the Helmholtz Institute, Biomedical Research Centre, München.

Study population: Patients planned for elective endarterectomy for symptomatic carotid stenosis will undergo prior to surgery imaging with an optoacoustic device before and after intravenous injection with the VEGF-targeted optical imaging agent Bevacizumab-800CW.

Intervention: Patients planned to undergo endarterectomy for symptomatic carotid stenosis will be consented for this study. The procedure will in no way delay the time interval between onset of symptoms and intervention. Three days before the planned fluorescent optoacoustic scanning, the patients will undergo optoacoustic imaging as a reference. Patients then receive an intravenous injection of 4,5 mg flat-dose of Bevacizumab-800CW. Three days after tracer administration, mostly

© UMCG october 2018 Version 2.0 8 of 40

the day patients are admitted to the hospital as standard-of-care, patients will undergo final optoacoustic imaging.

Main study parameters/endpoints:

Primary Objective:

  • Feasibility of optoacoustic imaging to image the carotid artery and detect plaque formation in patients with symptomatic carotid artery disease.
  • Pre-operative detection of the atherosclerotic plaque in symptomatic carotid stenosis by the VEGF-targeted optical imaging agent optical imaging agent Bevacizumab-800CW using optoacoustic imaging subsequently correlated ex vivo for VEGF upregulation within the plaque indicative for increased angiogenesis.

Type d'étude

Interventionnel

Inscription (Anticipé)

15

Phase

  • N'est pas applicable

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

21 ans et plus (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Oui

Sexes éligibles pour l'étude

Tout

La description

Inclusion Criteria:

  • Patients above the age of 21 with an indication to undergo a carotid endarterectomy for suspected symptomatic atherosclerotic plaque based on the presence of a CVA and/or transient ischemic attacks (TIA's), including amourosis fugax.

    1. Patients with significant and symptomatic carotid stenosis who are scheduled for carotid endarterectomy as decided by the surgeon or the Multi-Disciplinary Carotid Board

Exclusion Criteria:

  1. Medical or psychiatric condition that compromises the patient's ability to give informed consent
  2. Pregnant or lactating women
  3. Significantrenal(creatinine>110μmol/L)dysfunction
  4. History of iodine allergy or anaphylactic reactions to insect bites or medication or previous allergic reaction to bevacizumab
  5. Presence or history of hyperthyroidism

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Faisabilité de l'appareil
  • Répartition: N / A
  • Modèle interventionnel: Affectation à un seul groupe
  • Masquage: Aucun (étiquette ouverte)

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: Optoacoustic imaging
Optoacoustic Imaging before and after tracer administration
Multispectral Optoacoustic Tomography is a new emerging imaging technique which uses laser light to heat up molecules with a high pulsed laser. The molecules undergo thermal expansion and produces sound waves, which can be detected by special transducers. The device can pick up different signals in different wavelength to produce images with anatomic and biological information.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Feasibility of MSOT imaging
Délai: 12 months
Feasibility of optoacoustic imaging to image the carotid artery and detect plaque formation in patients with symptomatic carotid artery disease.
12 months
Ex vivo imaging
Délai: 12 months
Pre-operative detection of the atherosclerotic plaque in symptomatic carotid stenosis by the VEGF-targeted optical imaging agent optical imaging agent Bevacizumab-800CW using optoacoustic imaging subsequently correlated ex vivo for VEGF upregulation within the plaque indicative for increased angiogenesis.
12 months

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Location of Fluorescence
Délai: 12 months
Presence of fluorescent signaling after excision of the atherosclerotic plaque ex vivo as determined by flatbed scanning and fluorescence microscopy.
12 months

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Parrainer

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Anticipé)

10 avril 2019

Achèvement primaire (Anticipé)

31 décembre 2019

Achèvement de l'étude (Anticipé)

1 mars 2020

Dates d'inscription aux études

Première soumission

26 novembre 2018

Première soumission répondant aux critères de contrôle qualité

26 novembre 2018

Première publication (Réel)

29 novembre 2018

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

12 avril 2019

Dernière mise à jour soumise répondant aux critères de contrôle qualité

10 avril 2019

Dernière vérification

1 avril 2019

Plus d'information

Termes liés à cette étude

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

INDÉCIS

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

Essais cliniques sur MultiSpectral Optoacoustic Tomography

S'abonner