このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

PITT PCI Xience Registry

2016年1月5日 更新者:Oscar Marroquin、University of Pittsburgh

PITT PCI Xience Registry: A Prospective Evaluation of Dual Antiplatelet Therapy Compliance and Outcomes After Treatment With the Xience Stent

Stents are devices utilized to treat cholesterol blockages of the coronary (heart) arteries. The introduction of drug-eluting (coated) stents into clinical practice is regarded as a revolutionary breaktrhough, as it has reduced the incidence of re-narrowing of the arteries after percutaneous coronary interventions are performed. There has been, however, concerns of increased risk for clot formation in the heart arteries of patients treated with drug-eluting stents. Therefore, in order to lower the risk of clot formation, it is recommended that patients receiving these types of stents, be treated with dual antiplatelet therapy (blood thinning medication) for one year. The effect of this strategy, however, on clot formation and bleeding complications when utilizing "newer generation" stents, such as the Xience: Everolimus-eluting Stent, have not been well described.

Therefore, the aim of this registry study is to evaluate the risk of adverse cardiovascular events, including mortality, non-fatal myocardial infarction, stent thrombosis, hemorrhagic stroke, and severe bleeding in relation to the timing and discontinuation of dual antiplatelet therapy in patients treated with Xience drug-eluting stents, and compare it to patients that do not discontinue dual antiplatelet therapy.

調査の概要

状態

完了

詳細な説明

The introduction of drug-eluting stents (DES) into clinical practice is universally regarded as a revolutionary breakthrough in reducing the incidence of restenosis following percutaneous coronary intervention (PCI). The coating of stents with antiproliferative properties addresses a fundamental limitation of the earlier generation bare metal (uncoated) stents (BMS) - the in-growth of tissue through the struts of the stent that may eventually narrow the coronary artery resulting in recurrent ischemia. DES have greatly reduced the need for repeat revascularization, and thus, use of DES has rapidly become the de facto standard of care in the US.

The first two FDA-approved DES in the United States were the Cypher: Sirolimus-Eluting Coronary Stent and the TaxusExpress2™: Paclitaxel-Eluting Coronary Stent. Since then, the so-called 2nd generation DES which have come to market include the Xience: Everolimus-Eluting Coronary Stent and the Medtronic: Zotarolimus-Eluting Coronary Stent. Data from recent studies released in September of 2009 showed that Xience/Promus outperformed Boston's Taxus. Just prior to the release of this data, US market share was Xience 30%, Promus 24%, Taxus 22%, Endeavor 13%, and Cypher 11%. However, data was also released regarding Endeavor outperforming the Taxus stent as well, suggesting an upsurge is likely in US and world market share for Medtronic's Endeavor stent.

In the data recently presented from the SPIRIT IV trial, a randomized study between Xience and Taxus, significant benefits of Xience were found in comparison to the Taxus stent. There was a 38% reduction in target lesion failure and a 46% reduction in target lesion revascularization compared to Taxus. Notably, in this study of nearly 3700 patients, Xience had a low rate of stent thrombosis at 1-year of only 0.17%, compared to 0.85% for Taxus. The COMPARE study in higher-risk patients, also confirmed these results showing significant benefits of Xience V over Taxus Liberte at 1-year with regard to major adverse cardiac events and stent thrombosis.

These results suggest that there may be significant differences in outcomes favoring the use of 2nd generation DES, specifically as it relates to their superiority to 1st generation DES in reducing the need for repeat revascularization. There is, however, limited data examining the long-term safety of these devices when used in routine clinical practice. Furthermore, these DES have still not been fully studied in specific patient populations commonly encountered in routine clinical practice, including those with diabetes, chronic kidney disease, long-lesions, small vessels, and left main disease, among others. The outcomes revolve not only around efficacy of these stents in different clinical and angiographic scenarios, but also around the safety profiles. In particular, there has been great attention placed not only on the risk of stent thrombosis but also the timing of these events with the various DES, and how to reduce the incidence of them. The data available to date suggest favorable safety results for the Xience stent. However, in the ever changing world of dual antiplatelet therapy, and the duration of it, further understanding of these interactions are required. Currently, the majority of our efforts in reducing stent thrombosis have been channeled through more aggressive and longer duration of dual antiplatelet therapy. The effect of such strategies on other endpoints, such as bleeding complications after PCI, is unknown. These treatment strategies are based on our understanding of the need for dual antiplatelet therapy with 1st generation DES. Whether these same paradigms apply to 2nd generation DES, such as the Xience stent, is unclear. Furthermore, given that there continue to be significant questions regarding the precise rates of relatively rare clinical events, such as stent thrombosis and bleeding, strategies that allow us to estimate these rates when these devices are used in routine clinical practice, are warranted.

Specifically, the clinical impact of transient or permanent discontinuation of dual-antiplatelet therapy on these endpoints at various intervals after Xience implantation in routine clinical practice, has not been well characterized. As such, there continues to be considerable variability regarding the duration of dual antiplatelet therapy in routine clinical practice, regardless of the type of DES utilized. Therefore, a registry with rigorous long-term follow-up of patients treated with the Xience stent, that collects information on rare events, compliance with dual antiplatelet therapy, and relationships between use/non-use of dual antiplatelet therapy and adverse events would address these goals.

Accordingly, to better understand the long-term safety profile of the Xience stent in the overall population, as well as in those in whom dual antiplatelet therapy is discontinued, we propose to evaluate integrated patient data from the University of Pittsburgh Medical Center (UPMC) network system using two well-established institutions: the UPMC clinical sites and the University of Pittsburgh's Epidemiology Data Center (EDC). In brief, we propose to create the UPMC PCI-XIENCE registry, which will integrate the large-volume UPMC clinical sites with the well-established EDC as the data coordinating center. This will allow us to further investigate the long-term safety of the Xience stent as it is used in routine clinical practice.

Thus, the Specific Aims are to:

  1. Evaluate the risk of stent thrombosis, hemorrhagic stroke, and severe bleeding in relation to the timing and discontinuation of dual anti-platelet therapy in patients treated with Xience drug-eluting stents.
  2. Study the safety and efficacy of the Xience stent within specific understudied patient (diabetes mellitus, chronic kidney disease, women, minorities, etc) and angiographic (left main, bifurcation, saphenous vein graft, and small vessel disease) subgroups, among others.

研究の種類

観察的

入学 (実際)

2506

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

    • Pennsylvania
      • Pittsburgh、Pennsylvania、アメリカ、15213
        • University of Pittsburgh Medical Center

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年歳以上 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

サンプリング方法

非確率サンプル

調査対象母集団

The study population will consist of all consecutive patients who undergo coronary stenting with the Xience drug-eluting stent in any of the 4 University of Pittsburgh Medical Center's Hospitals (UPMC Presbyterian, UPMC Shadyside, UPMC Mercy, and UPMC Passavant).

説明

Inclusion Criteria:

  • Undergoing a coronary stenting procedure with the Xience drug-eluting stent
  • Signed informed consent

Exclusion Criteria:

  • Inability to sign informed consent.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

コホートと介入

グループ/コホート
CAD treated with Xience stents
Patients with CAD who undergo successful stenting with the Xience drug-eluting stent will represent the patient population.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Major Adverse Cardiovascular Events (MACE)
時間枠:24 months
Combined end-point of all cause mortality, non-fatal myocardial infarction, stent thrombosis, need for repeat revascularization.
24 months

二次結果の測定

結果測定
メジャーの説明
時間枠
Major Bleeding Events
時間枠:24 months
A combined endpoint including subarachnoid hemorrhage, intracerebral hemorrhage, other/unspecified intracranial hemorrhage, gastric ulcer or gastrointestinal hemorrhage.
24 months

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

協力者

捜査官

  • 主任研究者:Oscar C Marroquin, MD、University of Pittsburgh

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始

2011年8月1日

一次修了 (実際)

2015年2月1日

研究の完了 (実際)

2015年12月1日

試験登録日

最初に提出

2011年2月15日

QC基準を満たした最初の提出物

2011年2月16日

最初の投稿 (見積もり)

2011年2月18日

学習記録の更新

投稿された最後の更新 (見積もり)

2016年1月7日

QC基準を満たした最後の更新が送信されました

2016年1月5日

最終確認日

2016年1月1日

詳しくは

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

冠動脈疾患の臨床試験

  • Adelphi Values LLC
    Blueprint Medicines Corporation
    完了
    肥満細胞性白血病 (MCL) | 攻撃的な全身性肥満細胞症 (ASM) | SM w Assoc Clonal Hema Non-mast Cell Lineage Disease (SM-AHNMD) | くすぶり全身性肥満細胞症 (SSM) | 無痛性全身性肥満細胞症 (ISM) ISM サブグループが完全に募集されました
    アメリカ
3
購読する