PITT PCI Xience Registry
PITT PCI Xience Registry: A Prospective Evaluation of Dual Antiplatelet Therapy Compliance and Outcomes After Treatment With the Xience Stent
Stents are devices utilized to treat cholesterol blockages of the coronary (heart) arteries. The introduction of drug-eluting (coated) stents into clinical practice is regarded as a revolutionary breaktrhough, as it has reduced the incidence of re-narrowing of the arteries after percutaneous coronary interventions are performed. There has been, however, concerns of increased risk for clot formation in the heart arteries of patients treated with drug-eluting stents. Therefore, in order to lower the risk of clot formation, it is recommended that patients receiving these types of stents, be treated with dual antiplatelet therapy (blood thinning medication) for one year. The effect of this strategy, however, on clot formation and bleeding complications when utilizing "newer generation" stents, such as the Xience: Everolimus-eluting Stent, have not been well described.
Therefore, the aim of this registry study is to evaluate the risk of adverse cardiovascular events, including mortality, non-fatal myocardial infarction, stent thrombosis, hemorrhagic stroke, and severe bleeding in relation to the timing and discontinuation of dual antiplatelet therapy in patients treated with Xience drug-eluting stents, and compare it to patients that do not discontinue dual antiplatelet therapy.
Panoramica dello studio
Stato
Condizioni
Descrizione dettagliata
The introduction of drug-eluting stents (DES) into clinical practice is universally regarded as a revolutionary breakthrough in reducing the incidence of restenosis following percutaneous coronary intervention (PCI). The coating of stents with antiproliferative properties addresses a fundamental limitation of the earlier generation bare metal (uncoated) stents (BMS) - the in-growth of tissue through the struts of the stent that may eventually narrow the coronary artery resulting in recurrent ischemia. DES have greatly reduced the need for repeat revascularization, and thus, use of DES has rapidly become the de facto standard of care in the US.
The first two FDA-approved DES in the United States were the Cypher: Sirolimus-Eluting Coronary Stent and the TaxusExpress2™: Paclitaxel-Eluting Coronary Stent. Since then, the so-called 2nd generation DES which have come to market include the Xience: Everolimus-Eluting Coronary Stent and the Medtronic: Zotarolimus-Eluting Coronary Stent. Data from recent studies released in September of 2009 showed that Xience/Promus outperformed Boston's Taxus. Just prior to the release of this data, US market share was Xience 30%, Promus 24%, Taxus 22%, Endeavor 13%, and Cypher 11%. However, data was also released regarding Endeavor outperforming the Taxus stent as well, suggesting an upsurge is likely in US and world market share for Medtronic's Endeavor stent.
In the data recently presented from the SPIRIT IV trial, a randomized study between Xience and Taxus, significant benefits of Xience were found in comparison to the Taxus stent. There was a 38% reduction in target lesion failure and a 46% reduction in target lesion revascularization compared to Taxus. Notably, in this study of nearly 3700 patients, Xience had a low rate of stent thrombosis at 1-year of only 0.17%, compared to 0.85% for Taxus. The COMPARE study in higher-risk patients, also confirmed these results showing significant benefits of Xience V over Taxus Liberte at 1-year with regard to major adverse cardiac events and stent thrombosis.
These results suggest that there may be significant differences in outcomes favoring the use of 2nd generation DES, specifically as it relates to their superiority to 1st generation DES in reducing the need for repeat revascularization. There is, however, limited data examining the long-term safety of these devices when used in routine clinical practice. Furthermore, these DES have still not been fully studied in specific patient populations commonly encountered in routine clinical practice, including those with diabetes, chronic kidney disease, long-lesions, small vessels, and left main disease, among others. The outcomes revolve not only around efficacy of these stents in different clinical and angiographic scenarios, but also around the safety profiles. In particular, there has been great attention placed not only on the risk of stent thrombosis but also the timing of these events with the various DES, and how to reduce the incidence of them. The data available to date suggest favorable safety results for the Xience stent. However, in the ever changing world of dual antiplatelet therapy, and the duration of it, further understanding of these interactions are required. Currently, the majority of our efforts in reducing stent thrombosis have been channeled through more aggressive and longer duration of dual antiplatelet therapy. The effect of such strategies on other endpoints, such as bleeding complications after PCI, is unknown. These treatment strategies are based on our understanding of the need for dual antiplatelet therapy with 1st generation DES. Whether these same paradigms apply to 2nd generation DES, such as the Xience stent, is unclear. Furthermore, given that there continue to be significant questions regarding the precise rates of relatively rare clinical events, such as stent thrombosis and bleeding, strategies that allow us to estimate these rates when these devices are used in routine clinical practice, are warranted.
Specifically, the clinical impact of transient or permanent discontinuation of dual-antiplatelet therapy on these endpoints at various intervals after Xience implantation in routine clinical practice, has not been well characterized. As such, there continues to be considerable variability regarding the duration of dual antiplatelet therapy in routine clinical practice, regardless of the type of DES utilized. Therefore, a registry with rigorous long-term follow-up of patients treated with the Xience stent, that collects information on rare events, compliance with dual antiplatelet therapy, and relationships between use/non-use of dual antiplatelet therapy and adverse events would address these goals.
Accordingly, to better understand the long-term safety profile of the Xience stent in the overall population, as well as in those in whom dual antiplatelet therapy is discontinued, we propose to evaluate integrated patient data from the University of Pittsburgh Medical Center (UPMC) network system using two well-established institutions: the UPMC clinical sites and the University of Pittsburgh's Epidemiology Data Center (EDC). In brief, we propose to create the UPMC PCI-XIENCE registry, which will integrate the large-volume UPMC clinical sites with the well-established EDC as the data coordinating center. This will allow us to further investigate the long-term safety of the Xience stent as it is used in routine clinical practice.
Thus, the Specific Aims are to:
- Evaluate the risk of stent thrombosis, hemorrhagic stroke, and severe bleeding in relation to the timing and discontinuation of dual anti-platelet therapy in patients treated with Xience drug-eluting stents.
- Study the safety and efficacy of the Xience stent within specific understudied patient (diabetes mellitus, chronic kidney disease, women, minorities, etc) and angiographic (left main, bifurcation, saphenous vein graft, and small vessel disease) subgroups, among others.
Tipo di studio
Iscrizione (Effettivo)
Contatti e Sedi
Luoghi di studio
-
-
Pennsylvania
-
Pittsburgh, Pennsylvania, Stati Uniti, 15213
- University of Pittsburgh Medical Center
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
- Undergoing a coronary stenting procedure with the Xience drug-eluting stent
- Signed informed consent
Exclusion Criteria:
- Inability to sign informed consent.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
Coorti e interventi
Gruppo / Coorte |
---|
CAD treated with Xience stents
Patients with CAD who undergo successful stenting with the Xience drug-eluting stent will represent the patient population.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
---|---|---|
Major Adverse Cardiovascular Events (MACE)
Lasso di tempo: 24 months
|
Combined end-point of all cause mortality, non-fatal myocardial infarction, stent thrombosis, need for repeat revascularization.
|
24 months
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
---|---|---|
Major Bleeding Events
Lasso di tempo: 24 months
|
A combined endpoint including subarachnoid hemorrhage, intracerebral hemorrhage, other/unspecified intracranial hemorrhage, gastric ulcer or gastrointestinal hemorrhage.
|
24 months
|
Collaboratori e investigatori
Sponsor
Collaboratori
Investigatori
- Investigatore principale: Oscar C Marroquin, MD, University of Pittsburgh
Studiare le date dei record
Studia le date principali
Inizio studio
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Stima)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- 0022189
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .
Prove cliniche su Disfunsione dell'arteria coronaria
-
Tel-Aviv Sourasky Medical CenterCompletatoSoggetti consecutivi che sono idonei per una coronaria | Angioplastica di de Novo Lesion(s) in Native Coronary | Le arterie dovrebbero essere sottoposte a screening per l'idoneità. | Un numero totale di 200 pazienti che soddisfano la selezione | Criteri e disponibilità a firmare il consenso... e altre condizioniIsraele