Ultrasonography for Prediction of Extubation Success: a Holistic Approach (APEX)
調査の概要
詳細な説明
Weaning patients in the intensive care unit (ICU) from the mechanical ventilator is a critical period and accounts for 40% of the duration of mechanical ventilation itself. Weaning failure includes failing the initial spontaneous breathing trial (SBT) and patients with extubation failure. Extubation failure is defined as reintubation or need for rescue non-invasive ventilation within 48 hours following extubation. Patients failing extubation experience increased time spent on the mechanical ventilator and even increased mortality rates. Given these risks, predicting readiness for extubation is of key importance in the ICU.
Studies have shown, that US is a viable tool for routine use due to its bedside availability and non-invasiveness, while still maintaining excellent predictive values for its respective applications. For this reason, over the past years, critical care ultrasonography (US) has become an important part of routine bedside assessment Lately, the diaphragm has been studied extensively, due to its strong role in sustaining spontaneous breathing. Especially predicting extubation outcomes
has become a great field of interest and different studies have been conducted on this topic. Currently, indices such as diaphragm thickening (Tdi), diaphragm thickness (Tdi%) and diaphragm motion are the most frequently used parameters. Of these, thickening fraction seems to be the most promising to predict successful extubation.
However, all of the studies conducted, solely looked at diaphragm function and compared them to current standards such as the rapid shallow breathing index, while disregarding other factors strongly correlated to extubation failure, e.g. respiratory and cardiac function, as proposed by Mayo et al. Taking heart and lung function into account as well seems to be an interesting approach, because additional measurements could possibly improve predictive value while putting no further burden on the patient. Furthermore, both heart and lungs can be assessed quickly and easily by ultrasound. Cardiac parameters that are potentially useful are left ventricular function, mitral diastolic inflow and cardiac output. Regarding the lungs, pleural effusion is associated with rate of success for extubation. Effusion is detected easily and recent studies have shown, that in an ICU setting a simple 8 region protocol is sufficient to detect extra vascular lung water.
The investigators hypothesise that a holistic US approach, including measurements of heart, lungs and diaphragm, will be superior to the core diagnostic parameters of the diaphragm in predicting extubation success in mechanically ventilated critical care patients.
研究の種類
入学 (実際)
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
サンプリング方法
調査対象母集団
説明
Inclusion Criteria:
- Ventilated for > 72 hours
- Passed spontaneous breathing trial
Exclusion Criteria:
- Planned NIV
- Palliative Extubation
- Tracheostomy
- Paraplegia above Th 8
研究計画
研究はどのように設計されていますか?
デザインの詳細
コホートと介入
グループ/コホート |
介入・治療 |
|---|---|
|
Ventilated72h
Patient that were ventilated for at least 72 hours
|
Point of care ultrasound as part of routine physical examination
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Sensitivity
時間枠:48 hours
|
Sensitivity of thickening fraction for extubation failure
|
48 hours
|
|
Specificity
時間枠:48 hours
|
Specificity of thickening fraction for extubation failure
|
48 hours
|
|
Area under the Curve
時間枠:48 hours
|
Area under the receiver operator curve
|
48 hours
|
|
Correlation of ultrasound variables with extubation outcome
時間枠:48 hours
|
Correlation of ultrasound variables with extubation outcome through (logistic)regression analysis.
|
48 hours
|
協力者と研究者
出版物と役立つリンク
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
IPD 共有時間枠
IPD 共有サポート情報タイプ
- STUDY_PROTOCOL
- SAP
- ICF
- CSR
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。