此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Ultrasonography for Prediction of Extubation Success: a Holistic Approach (APEX)

2019年12月10日 更新者:Jasper M Smit, MD、Amsterdam UMC, location VUmc
This study evaluates thickening fraction alone and together with other ultrasound parameters of heart and lungs as predictors for extubation outcome

研究概览

地位

完全的

详细说明

Weaning patients in the intensive care unit (ICU) from the mechanical ventilator is a critical period and accounts for 40% of the duration of mechanical ventilation itself. Weaning failure includes failing the initial spontaneous breathing trial (SBT) and patients with extubation failure. Extubation failure is defined as reintubation or need for rescue non-invasive ventilation within 48 hours following extubation. Patients failing extubation experience increased time spent on the mechanical ventilator and even increased mortality rates. Given these risks, predicting readiness for extubation is of key importance in the ICU.

Studies have shown, that US is a viable tool for routine use due to its bedside availability and non-invasiveness, while still maintaining excellent predictive values for its respective applications. For this reason, over the past years, critical care ultrasonography (US) has become an important part of routine bedside assessment Lately, the diaphragm has been studied extensively, due to its strong role in sustaining spontaneous breathing. Especially predicting extubation outcomes

has become a great field of interest and different studies have been conducted on this topic. Currently, indices such as diaphragm thickening (Tdi), diaphragm thickness (Tdi%) and diaphragm motion are the most frequently used parameters. Of these, thickening fraction seems to be the most promising to predict successful extubation.

However, all of the studies conducted, solely looked at diaphragm function and compared them to current standards such as the rapid shallow breathing index, while disregarding other factors strongly correlated to extubation failure, e.g. respiratory and cardiac function, as proposed by Mayo et al. Taking heart and lung function into account as well seems to be an interesting approach, because additional measurements could possibly improve predictive value while putting no further burden on the patient. Furthermore, both heart and lungs can be assessed quickly and easily by ultrasound. Cardiac parameters that are potentially useful are left ventricular function, mitral diastolic inflow and cardiac output. Regarding the lungs, pleural effusion is associated with rate of success for extubation. Effusion is detected easily and recent studies have shown, that in an ICU setting a simple 8 region protocol is sufficient to detect extra vascular lung water.

The investigators hypothesise that a holistic US approach, including measurements of heart, lungs and diaphragm, will be superior to the core diagnostic parameters of the diaphragm in predicting extubation success in mechanically ventilated critical care patients.

研究类型

观察性的

注册 (实际的)

83

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

取样方法

概率样本

研究人群

The study population consisted of adult (>18 years) patients, admitted to the ICU and ventilated for at least 72h.

描述

Inclusion Criteria:

  • Ventilated for > 72 hours
  • Passed spontaneous breathing trial

Exclusion Criteria:

  • Planned NIV
  • Palliative Extubation
  • Tracheostomy
  • Paraplegia above Th 8

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
干预/治疗
Ventilated72h
Patient that were ventilated for at least 72 hours
Point of care ultrasound as part of routine physical examination

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Sensitivity
大体时间:48 hours
Sensitivity of thickening fraction for extubation failure
48 hours
Specificity
大体时间:48 hours
Specificity of thickening fraction for extubation failure
48 hours
Area under the Curve
大体时间:48 hours
Area under the receiver operator curve
48 hours
Correlation of ultrasound variables with extubation outcome
大体时间:48 hours
Correlation of ultrasound variables with extubation outcome through (logistic)regression analysis.
48 hours

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2016年9月1日

初级完成 (实际的)

2019年11月29日

研究完成 (实际的)

2019年12月2日

研究注册日期

首次提交

2019年12月9日

首先提交符合 QC 标准的

2019年12月10日

首次发布 (实际的)

2019年12月12日

研究记录更新

最后更新发布 (实际的)

2019年12月12日

上次提交的符合 QC 标准的更新

2019年12月10日

最后验证

2019年12月1日

更多信息

与本研究相关的术语

其他研究编号

  • 2016.465

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

是的

IPD 计划说明

Upon we request we can share our data to assist other researchers with interest in this field of research.

IPD 共享时间框架

After publication in a peer reviewed journal

IPD 共享支持信息类型

  • 研究方案
  • 树液
  • 国际碳纤维联合会
  • 企业社会责任

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅