In Group 1 and Group 2 participants in this study were scheduled for tooth extraction followed by immediate implant placement. One hour prior to the procedure, patients were administered 1 g of amoxicillin orally, which was continued at a dosage of twice daily for one week after the procedure. Teeth were extracted under local anesthesia using 4% articain with epi-nephrine 1:100000 (Ubistesin forte, 3M ESPE, USA), with an emphasis on minimizing trauma and avoiding flap elevation, employing root sectioning if necessary. Care was taken to preserve the marginal gingiva and papillae. Following extraction, the socket was cleaned and assessed. Osteotomies were created using the original drills in a sequence specified by the implant manufacturer. The implant was placed centrally in the me-sio-distal aspect and more towards the lingual/palatal side of the socket. The insertion torque was recorded with manual torque wrench. Anatomical or individual healing abutments were used after implant placement. Individual healing abutments were crafted chairside using original titanium temporary abutments and flowable composite (3M Supreme Filtek Flow, 3M ESPE, USA), creating critical and subcritical contours. The composite was polished meticulously. All immediate implant sites were grafted with allogenic cortical/cancellous particulate (1000-1700 micron) bone and healing abutments were secured on the implants with 15 Ncm torque. Postoperative instructions were provided both verbally and, in a booklet, advising patients to rinse their mouths twice daily for 2 weeks with a commercially available mouth rinse containing 0.12% chlorhexidine di-gluconate.
After 4 months, the osseointegration of implants was evaluated for presence or ab-sence of following symptoms: pain, recurrent peri-implant infections, mobility on manual palpation and continuous peri-implant radiolucency. If those symptoms were absent, implant was deemed successfully integrated and silicone impressions for final restorations were taken. Screw-retained full-contour zirconia crowns with ultra-polished subgingival areas, using the protocol described by Linkevicius et al. 2017 were delivered. The access holes were filled with Teflon tape, and while the top 1 mm was sealed with flowable composite (Figure 3D). Individual oral hygiene instructions were provided both verbally and in booklet form. Scheduling of follow-up visits were carried out after 1 year of last dental visit.
In Group 3 Following the extraction of molars under local anaesthesia, socket was debrided using surgical curette until hard bone surface was felt. Following copious irrigation with saline, an ultrawide diameter implant(8.0mm X8.0mm; Megagen Anyridge) was placed in the depth of the socket with zero insertion torque (T1). Socket was then allowed to fill with fresh blood. The remaining part of the socket present coronal to implant platform (measuring 6mm approx.) was then sealed with xenograft particles in a similar manner to alveolar ridge preservation. This was carried out in order to prevent the resorption of buccolingual width while simultaneously utilizing the benefits of immediate implant placement. In order to separate the xenograft particles from the oral microenvironment, a non-resorbable d-PTFE membrane was placed with its edges inserted into buccal and lingual flaps. This was further secured using criss cross sutures(5-0 Polyglycolic acid) along the occlusal surface. Suture removal was done 10 days post operatively and the site was allowed to heal for 04 months. d-PTFE membrane was then removed which revealed completely epithelialized with xenograft particles integrated over the implant platform which was confirmed on the radiograph.
Stage II implant exposure surgery was performed after 04 months of implant placement. Implant was deemed successful if there was no implant mobility and apparently healthy mucosa around implant.
研究の種類
入学 (推定)
段階
- 適用できない
連絡先と場所
研究連絡先
- 名前:Tomas Linkevicius, PhD, DDS
- 電話番号:+37068772840
- メール:tomas.linkevicius@lsmu.lt
研究連絡先のバックアップ
- 名前:Marius Svedas
- メール:svedasm@gmail.com
参加基準
適格基準
就学可能な年齢
- 大人
- 高齢者
健康ボランティアの受け入れ
説明
Inclusion Criteria:
- ≥ 18 years old.
- healthy patients without medical contraindications for dental implantation surgery.
- removable and non-molar teeth indicated for extraction in both jaws
- healthy soft tissues (bleeding on probing < 20%, plaque index < 25%);
- intact alveolar bone walls post-extraction
- signed informed consent form and permission to use the obtained data for research purposes.
Exclusion Criteria:
- Smokers (≥ 10 cigarettes per day);
- history of uncontrolled periodontitis;
- uncontrolled diabetes/alcoholism;
- use of drugs that may affect healing;
- persons who, due to health status, cannot be considered capable of reasonably assessing their interests;
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:非ランダム化
- 介入モデル:並列代入
- マスキング:独身
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:5-10 N/cm
Stability is low (5-10 N/cm), Megagen BlueDiamond implants will be inserted, and a temporary prosthesis will not be placed; the implant will be sutured.
|
After tooth extraction, dental implant is placed
After implant placement, bone graft is applied to extraction socket
Non-resorbable membrane is put on the implant to prevent loading
|
|
実験的:15-35 N/cm
Stability is moderate (15-35 N/cm), Megagen BlueDiamond implants will be inserted, and a custom plastic gingiva-forming healing abutment will be placed
|
After tooth extraction, dental implant is placed
After implant placement, bone graft is applied to extraction socket
Composite healing abutment is formed chairside after implant placement and abutment is attcahed to the implant
|
|
実験的:40 N/cm and more
Stability is high (40 N/cm and higher), Megagen BlueDiamond implants will be inserted, and a temporary plastic crown will be placed.
|
After tooth extraction, dental implant is placed
After implant placement, bone graft is applied to extraction socket
Prefabricated temporary crown is attcahed to the implant after implant placement
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Implant oseointegration
時間枠:After 4 months post-insertion
|
Implant will be considered integrated if implant will meet criteria (Buser et al, 1990) •. The implant is in its original position.
|
After 4 months post-insertion
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Implant insertion depth
時間枠:After implant placement and after 4 months post-healing
|
Implant insertion depth from free gingival margin till the neck of the implant will be measured in mm with 0.5 mm graded periodontal probe after implant insertion and 4 months after implant osseointegrartion
|
After implant placement and after 4 months post-healing
|
|
Marginal bone loss
時間枠:After delivery of implant restoration and after 1 y follow-up
|
Marginal bone loss will be measured in mm on radiographic images, which will be calibrated.Marginal bone loss around the implant was assessed by measuring the distance from the implant-abutment junction to the initial point of bone contact on both the mesial and distal sides, and an average was determined for each implant.
|
After delivery of implant restoration and after 1 y follow-up
|
|
PES (pink esthetic score) index
時間枠:After prosthesis delivery and after 1 year
|
The gingival response to a anterior esthetic evaluation is assessed by the Pink Esthetic Score (PES) from clinically according to seven variables scored from 0→2:
|
After prosthesis delivery and after 1 year
|
|
Implant stability quotient (ISQ) value
時間枠:After implant insertion and after osseointegration
|
Primary Implant stability was determined using resonance freaquency analyzer (RFA) in both the buccolingual and mesiodistal direction and an average value is noted down.
RFA calculates value in terms of ISQ (Implant Stability Quotient) ranging from 0-100.
ISQ value was measured for each implant at the baseline followed by just before the final restoration.
|
After implant insertion and after osseointegration
|
|
Plaque Index (PI)
時間枠:After prosthesis delivery and after 1 year
|
Plaque index is calucated visually by scoring from 0-3. 0 = no plaque.
1 = separate flecks of plaque at the cervical margin of the tooth. 2 = a thin continuous band of plaque (up to 1 mm) at the cervical margin of the tooth.
3 = a band of plaque wider than 1 mm but covering less than one-third of the crown of the tooth.
|
After prosthesis delivery and after 1 year
|
|
Gingival volume around the implants
時間枠:After prosthesis delivery and after 1 year
|
Gingival volume around the implants will measured in mm3 from intraoral scans of implant-supported restoration.
|
After prosthesis delivery and after 1 year
|
|
Probing Pocket Depth (PPD)
時間枠:After prosthesis delivery and after 1 year
|
PPD will measured in mm with periodontal probe.
Periodontal probing depth (PPD) is measured from the gingival margin to the base/bottom (coronal portion of the junctional epithelium (JE) of the periodontal pocket to the nearest mm. 4 points around each implant prosthesis will be measured - mesiobucal, distobucal, mesiolingual/palatinal and distolingual/palatinal.
The mean number of 4 measurements will be presented
|
After prosthesis delivery and after 1 year
|
|
Bleeding on Probing (BOP)
時間枠:After prosthesis delivery and after 1 year
|
Bleeding on probing is registered during pocket probing.
Sites are characterized by the absence of BOP as well as the absence of GI bleeding (scores 0 and 1)
|
After prosthesis delivery and after 1 year
|
協力者と研究者
スポンサー
捜査官
- 主任研究者:Tomas Linkevicius, PhD, DDS、Lithuanian University of Health Sciences
研究記録日
主要日程の研究
研究開始 (推定)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
キーワード
その他の研究ID番号
- Nr. 2026/4-1735-1199
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
IPD 共有時間枠
IPD 共有アクセス基準
IPD 共有サポート情報タイプ
- STUDY_PROTOCOL
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。
歯科インプラントの即時装着の臨床試験
-
UConn HealthDentsply Astra tech完了
-
Universidade Federal Fluminense招待による登録インプラント周囲炎 | オッセオインテグレーション | 歯科インプラントのオッセオインテグレーション障害 | 歯科インプラントの安定性 | 前向き研究 | Immediate Loading Protocol を使用したインプラントの生存 | インプラント周囲の健康 | インプラント周囲組織 | インプラント周囲軟部組織の治癒ブラジル
Implant placementの臨床試験
-
Polares Medical SAPolares Medical, Inc.まだ募集していません
-
Abbott Medical Devices完了
-
Polares Medical SAPolares Medical, Inc.まだ募集していません
-
Seoul National University HospitalHansBiomed Co.,Ltd.積極的、募集していない