- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT07585539
Influence of the Primary Stability and Temporary Prosthetics
Influence of the Primary Stability and Temporary Prosthetics of a Placed Dental Implant on Implant Osseointegration and Further Function When Performing Immediate Implantation in the Posterior Tooth Regions.
Visão geral do estudo
Status
Condições
Descrição detalhada
In Group 1 and Group 2 participants in this study were scheduled for tooth extraction followed by immediate implant placement. One hour prior to the procedure, patients were administered 1 g of amoxicillin orally, which was continued at a dosage of twice daily for one week after the procedure. Teeth were extracted under local anesthesia using 4% articain with epi-nephrine 1:100000 (Ubistesin forte, 3M ESPE, USA), with an emphasis on minimizing trauma and avoiding flap elevation, employing root sectioning if necessary. Care was taken to preserve the marginal gingiva and papillae. Following extraction, the socket was cleaned and assessed. Osteotomies were created using the original drills in a sequence specified by the implant manufacturer. The implant was placed centrally in the me-sio-distal aspect and more towards the lingual/palatal side of the socket. The insertion torque was recorded with manual torque wrench. Anatomical or individual healing abutments were used after implant placement. Individual healing abutments were crafted chairside using original titanium temporary abutments and flowable composite (3M Supreme Filtek Flow, 3M ESPE, USA), creating critical and subcritical contours. The composite was polished meticulously. All immediate implant sites were grafted with allogenic cortical/cancellous particulate (1000-1700 micron) bone and healing abutments were secured on the implants with 15 Ncm torque. Postoperative instructions were provided both verbally and, in a booklet, advising patients to rinse their mouths twice daily for 2 weeks with a commercially available mouth rinse containing 0.12% chlorhexidine di-gluconate.
After 4 months, the osseointegration of implants was evaluated for presence or ab-sence of following symptoms: pain, recurrent peri-implant infections, mobility on manual palpation and continuous peri-implant radiolucency. If those symptoms were absent, implant was deemed successfully integrated and silicone impressions for final restorations were taken. Screw-retained full-contour zirconia crowns with ultra-polished subgingival areas, using the protocol described by Linkevicius et al. 2017 were delivered. The access holes were filled with Teflon tape, and while the top 1 mm was sealed with flowable composite (Figure 3D). Individual oral hygiene instructions were provided both verbally and in booklet form. Scheduling of follow-up visits were carried out after 1 year of last dental visit.
In Group 3 Following the extraction of molars under local anaesthesia, socket was debrided using surgical curette until hard bone surface was felt. Following copious irrigation with saline, an ultrawide diameter implant(8.0mm X8.0mm; Megagen Anyridge) was placed in the depth of the socket with zero insertion torque (T1). Socket was then allowed to fill with fresh blood. The remaining part of the socket present coronal to implant platform (measuring 6mm approx.) was then sealed with xenograft particles in a similar manner to alveolar ridge preservation. This was carried out in order to prevent the resorption of buccolingual width while simultaneously utilizing the benefits of immediate implant placement. In order to separate the xenograft particles from the oral microenvironment, a non-resorbable d-PTFE membrane was placed with its edges inserted into buccal and lingual flaps. This was further secured using criss cross sutures(5-0 Polyglycolic acid) along the occlusal surface. Suture removal was done 10 days post operatively and the site was allowed to heal for 04 months. d-PTFE membrane was then removed which revealed completely epithelialized with xenograft particles integrated over the implant platform which was confirmed on the radiograph.
Stage II implant exposure surgery was performed after 04 months of implant placement. Implant was deemed successful if there was no implant mobility and apparently healthy mucosa around implant.
Tipo de estudo
Inscrição (Estimado)
Estágio
- Não aplicável
Contactos e Locais
Contato de estudo
- Nome: Tomas Linkevicius, PhD, DDS
- Número de telefone: +37068772840
- E-mail: tomas.linkevicius@lsmu.lt
Estude backup de contato
- Nome: Marius Svedas
- E-mail: svedasm@gmail.com
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
- Adulto
- Adulto mais velho
Aceita Voluntários Saudáveis
Descrição
Inclusion Criteria:
- ≥ 18 years old.
- healthy patients without medical contraindications for dental implantation surgery.
- removable and non-molar teeth indicated for extraction in both jaws
- healthy soft tissues (bleeding on probing < 20%, plaque index < 25%);
- intact alveolar bone walls post-extraction
- signed informed consent form and permission to use the obtained data for research purposes.
Exclusion Criteria:
- Smokers (≥ 10 cigarettes per day);
- history of uncontrolled periodontitis;
- uncontrolled diabetes/alcoholism;
- use of drugs that may affect healing;
- persons who, due to health status, cannot be considered capable of reasonably assessing their interests;
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: Não randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Solteiro
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: 5-10 N/cm
Stability is low (5-10 N/cm), Megagen BlueDiamond implants will be inserted, and a temporary prosthesis will not be placed; the implant will be sutured.
|
After tooth extraction, dental implant is placed
After implant placement, bone graft is applied to extraction socket
Non-resorbable membrane is put on the implant to prevent loading
|
|
Experimental: 15-35 N/cm
Stability is moderate (15-35 N/cm), Megagen BlueDiamond implants will be inserted, and a custom plastic gingiva-forming healing abutment will be placed
|
After tooth extraction, dental implant is placed
After implant placement, bone graft is applied to extraction socket
Composite healing abutment is formed chairside after implant placement and abutment is attcahed to the implant
|
|
Experimental: 40 N/cm and more
Stability is high (40 N/cm and higher), Megagen BlueDiamond implants will be inserted, and a temporary plastic crown will be placed.
|
After tooth extraction, dental implant is placed
After implant placement, bone graft is applied to extraction socket
Prefabricated temporary crown is attcahed to the implant after implant placement
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Implant oseointegration
Prazo: After 4 months post-insertion
|
Implant will be considered integrated if implant will meet criteria (Buser et al, 1990) •. The implant is in its original position.
|
After 4 months post-insertion
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Implant insertion depth
Prazo: After implant placement and after 4 months post-healing
|
Implant insertion depth from free gingival margin till the neck of the implant will be measured in mm with 0.5 mm graded periodontal probe after implant insertion and 4 months after implant osseointegrartion
|
After implant placement and after 4 months post-healing
|
|
Marginal bone loss
Prazo: After delivery of implant restoration and after 1 y follow-up
|
Marginal bone loss will be measured in mm on radiographic images, which will be calibrated.Marginal bone loss around the implant was assessed by measuring the distance from the implant-abutment junction to the initial point of bone contact on both the mesial and distal sides, and an average was determined for each implant.
|
After delivery of implant restoration and after 1 y follow-up
|
|
PES (pink esthetic score) index
Prazo: After prosthesis delivery and after 1 year
|
The gingival response to a anterior esthetic evaluation is assessed by the Pink Esthetic Score (PES) from clinically according to seven variables scored from 0→2:
|
After prosthesis delivery and after 1 year
|
|
Implant stability quotient (ISQ) value
Prazo: After implant insertion and after osseointegration
|
Primary Implant stability was determined using resonance freaquency analyzer (RFA) in both the buccolingual and mesiodistal direction and an average value is noted down.
RFA calculates value in terms of ISQ (Implant Stability Quotient) ranging from 0-100.
ISQ value was measured for each implant at the baseline followed by just before the final restoration.
|
After implant insertion and after osseointegration
|
|
Plaque Index (PI)
Prazo: After prosthesis delivery and after 1 year
|
Plaque index is calucated visually by scoring from 0-3. 0 = no plaque.
1 = separate flecks of plaque at the cervical margin of the tooth. 2 = a thin continuous band of plaque (up to 1 mm) at the cervical margin of the tooth.
3 = a band of plaque wider than 1 mm but covering less than one-third of the crown of the tooth.
|
After prosthesis delivery and after 1 year
|
|
Gingival volume around the implants
Prazo: After prosthesis delivery and after 1 year
|
Gingival volume around the implants will measured in mm3 from intraoral scans of implant-supported restoration.
|
After prosthesis delivery and after 1 year
|
|
Probing Pocket Depth (PPD)
Prazo: After prosthesis delivery and after 1 year
|
PPD will measured in mm with periodontal probe.
Periodontal probing depth (PPD) is measured from the gingival margin to the base/bottom (coronal portion of the junctional epithelium (JE) of the periodontal pocket to the nearest mm. 4 points around each implant prosthesis will be measured - mesiobucal, distobucal, mesiolingual/palatinal and distolingual/palatinal.
The mean number of 4 measurements will be presented
|
After prosthesis delivery and after 1 year
|
|
Bleeding on Probing (BOP)
Prazo: After prosthesis delivery and after 1 year
|
Bleeding on probing is registered during pocket probing.
Sites are characterized by the absence of BOP as well as the absence of GI bleeding (scores 0 and 1)
|
After prosthesis delivery and after 1 year
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Investigadores
- Investigador principal: Tomas Linkevicius, PhD, DDS, Lithuanian University of Health Sciences
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Estimado)
Conclusão Primária (Estimado)
Conclusão do estudo (Estimado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Outros números de identificação do estudo
- Nr. 2026/4-1735-1199
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Descrição do plano IPD
Prazo de Compartilhamento de IPD
Critérios de acesso de compartilhamento IPD
Tipo de informação de suporte de compartilhamento de IPD
- PROTOCOLO DE ESTUDO
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .
Ensaios clínicos em Implant placement
-
Apreo Health, Inc.ConcluídoEnfisema ou DPOCAustrália
-
Hayat Abad Medical Complex, Peshawar.Ativo, não recrutandoPieloplastia | Internação hospitalar | Complicações de procedimentos cirúrgicos ou cuidados médicosPaquistão
-
Ideal Implant IncorporatedConcluídoImplantes mamáriosEstados Unidos
-
Apreo Health, Inc.Ativo, não recrutandoEnfisema ou DPOCReino Unido, Holanda, Áustria
-
Cukurova UniversityDentsply Sirona ImplantsDesconhecidoPerda óssea alveolar | Falha Biológica Pós-Osseointegração de Implantes DentáriosPeru
-
Across Co., Ltd.ConcluídoCorreção de Dobras NasolabiaisRepublica da Coréia
-
Polares Medical SAPolares Medical, Inc.Ainda não está recrutando
-
Polares Medical SAPolares Medical, Inc.Ainda não está recrutandoDoença Degenerativa da Valva Mitral
-
Polares Medical SAPolares Medical, Inc.Ainda não está recrutando
-
University of MichiganConcluídoTecido GengivalEstados Unidos