SpO2 Infant and Pediatric Study (SpO2 Peds)
Assessment of TruSignal SpO2 Form, Fit and Clinical Performance With Infant and Child Patients
調査の概要
詳細な説明
This prospective clinical study evaluates a pulse oximetry sensor in hospitalized infants (28 days to 23 months) and children (2-12 years) under routine clinical conditions. The primary objective is to assess the accuracy and agreement of SpO₂ measurements compared with reference SaO₂ values obtained from CO-oximetry analysis of simultaneously drawn arterial blood, using methods aligned with ISO 80601-2-61: 2026 3rd edition published in April 2026.
Secondary objectives include measuring the proportion of time the device produces invalid or unusable data to assess reliability for clinical use. The safety objective is to collect safety information, including type and number of AEs, SAEs, and device issues. Results may support product development, regulatory submissions, and marketing activities.
研究の種類
入学 (推定)
段階
- 適用できない
連絡先と場所
研究場所
-
-
Nebraska
-
Omaha、Nebraska、アメリカ、68114
- University of Nebraska Medical Center Children's Hospital
-
コンタクト:
- Michael Facciolo, MD
- 電話番号:402-671-6325
- メール:mfacciolo@childrensnebraska.org
-
主任研究者:
- Michael Facciolo, MD
-
-
参加基準
適格基準
就学可能な年齢
- 子
健康ボランティアの受け入れ
説明
Inclusion Criteria:
- subjects are 1-23 months (infant cohort) or 2-12 years old (child cohort)
- requiring arterial blood samples per the site's standard of care.
Exclusion Criteria:
- Fractional Methemoglobinemia (FMetHb >2%) or Fractional carboxyhemoglobinemia (FCOHb >3%), within 24 hours of arterial blood draw.
- Severe anemia (tHb <7g/dL) within 4 hours prior to arterial blood gas draw.
- Hematocrit (Hct) <25 within 4 hours prior to arterial blood gas draw.
- Patients with injuries, deformities, or abnormalities which may prevent proper application of the sensor.
- Patients on Extracorporeal Membrane Oxygenation (ECMO).
- Patients receiving point of care (POC) testing for blood gases.
- Patients with diseases/conditions that may cause differential (or reverse differential) cyanosis including, but not limited to:
- Patent ductus arteriosus with pulmonary arterial hypertension.
- Pulmonary hypertension and left-heart abnormalities aortic arch hypoplasia, interrupted aortic arch, critical coarctation, and critical aortic stenosis.
- Children with transposition of the great arteries (TGA) and coarctation of the aorta or interrupted aortic arch, and TGA with suprasystemic pulmonary vascular resistance.
- At the discretion of the principal investigator or designee due to the subject health condition.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:デバイスの実現可能性
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:All Subjects
Participants participating in this study will be connected to SpO2 sensors.
SpO2 data will be independently collected from each sensor and paired with simultaneous arterial blood sample SaO₂ values.
The protocol is consistent with the ISO 80601-2-61 pulse oximetry standard.
|
SpO2 sensors use red and infrared LED light to estimate the arterial oxygen saturation.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Collection of SpO2 Percentage Sensor Data with simultaneous SaO2 values
時間枠:From enrollment to the end of standard of care arterial cannulation, approximately 1 week.
|
The collection of SpO2 percentage sensor data with simultaneous SaO2 values percentage from each subject enrolled in the study.
|
From enrollment to the end of standard of care arterial cannulation, approximately 1 week.
|
その他の成果指標
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
安全イベントの発生率
時間枠:4か月
|
有害事象の分析は、被験者ごとにリストされ、イベントのカウントと割合で要約され、イベントのある被験者のカウントと割合で要約されます。
|
4か月
|
協力者と研究者
スポンサー
出版物と役立つリンク
一般刊行物
- Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17(4):571-82. doi: 10.1080/10543400701329422.
- Bickler PE, Feiner JR, Severinghaus JW. Effects of skin pigmentation on pulse oximeter accuracy at low saturation. Anesthesiology. 2005 Apr;102(4):715-9. doi: 10.1097/00000542-200504000-00004.
- Okunlola OE, Lipnick MS, Batchelder PB, Bernstein M, Feiner JR, Bickler PE. Pulse Oximeter Performance, Racial Inequity, and the Work Ahead. Respir Care. 2022 Feb;67(2):252-257. doi: 10.4187/respcare.09795. Epub 2021 Nov 12.
- Ruppel H, Makeneni S, Faerber JA, Lane-Fall MB, Foglia EE, O'Byrne ML, Bonafide CP. Evaluating the Accuracy of Pulse Oximetry in Children According to Race. JAMA Pediatr. 2023 May 1;177(5):540-543. doi: 10.1001/jamapediatrics.2023.0071.
研究記録日
主要日程の研究
研究開始 (推定)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- SA-000192
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
米国で製造され、米国から輸出された製品。
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。