- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT02438228
Cardiac Output by Nine Different Pulse Contour Algorithms
Estimation of Cardiac Output by Nine Different Pulse Contour Algorithms Compared With Transpulmonary Thermodilution
연구 개요
상세 설명
After induction of anesthesia, a central venous catheter and a transpulmonary thermodilution catheter (Pulsion Medical Systems, Munich, Germany) are introduced in the right internal jugular vein and in the femoral artery, respectively. The thermodilution catheter is connected to a PiCCO2 monitor (Software version 1.3.0.8). Thereafter, placement of an esophageal doppler probe is performed and the probe is connected to a unique Monitoring System (Deltex Medical, Chichester, UK) with nine different pulse contour algorithms. Cardiac Output by esophageal doppler is used to calibrate the nine different pulse contour algorithms.
After induction of anesthesia and establishment of all monitoring devices, a passive leg raising maneouvre (PLR) is performed and hemodynamic variables including CO by transpulmonary thermodilution (COTPTD) and CO by nine different pulse contour algorithms (COX1-9) are recorded before, during and after PLR. Subsequently, measurements of COTPTD and COX1-9 are carried out every 10 minutes until the beginning of CPB. Fifteen minutes after weaning from cardiopulmonary bypass calibration of nine different pulse contour algorithms by esophageal doppler are performed again and measurements of CITPTD and CIPFX are restarted up to the end of the surgical Intervention.
연구 유형
등록 (실제)
단계
- 해당 없음
연락처 및 위치
연구 장소
-
-
-
Hamburg, 독일, 20099
- Berthold Bein
-
-
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria:
- Patients > 18 years of age with a left ventricular ejection fraction ≥ 0.5.
- Patients undergoing coronary artery bypass grafting.
Exclusion Criteria:
- Patients <18 years of age and with a left ventricular ejection fraction ≤0.5 are not considered for the study.
- Emergency procedures and patients with hemodynamic instability requiring continuous pharmacologic support, intracardiac shunts, severe aortic-, tricuspid- or mitral stenosis or insufficiency and mechanical circulatory support were also excluded.
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 할당: 해당 없음
- 중재 모델: 단일 그룹 할당
- 마스킹: 없음(오픈 라벨)
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
다른: Cardiac output measurement
|
Measurement of cardiac output by transpulmonary thermodilution, nine different pulse contour algorithms and esophageal doppler before, during and after a PLR-maneouvre and every 10 minutes before and after cardiopulmonary Bypass.
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
기간 |
|---|---|
|
Accuracy of cardiac output in l/min by nine different pulse contour algorithms compared with transpulmonary thermodilution
기간: After induction of anesthesia until the end of surgery
|
After induction of anesthesia until the end of surgery
|
공동 작업자 및 조사자
수사관
- 수석 연구원: Berthold Bein, MD, PhD, Asklepios Klinik St. Georg
간행물 및 유용한 링크
일반 간행물
- Critchley LA, Lee A, Ho AM. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg. 2010 Nov;111(5):1180-92. doi: 10.1213/ANE.0b013e3181f08a5b. Epub 2010 Aug 24.
- Suehiro K, Tanaka K, Funao T, Matsuura T, Mori T, Nishikawa K. Systemic vascular resistance has an impact on the reliability of the Vigileo-FloTrac system in measuring cardiac output and tracking cardiac output changes. Br J Anaesth. 2013 Aug;111(2):170-7. doi: 10.1093/bja/aet022. Epub 2013 Mar 10.
- Schloglhofer T, Gilly H, Schima H. Semi-invasive measurement of cardiac output based on pulse contour: a review and analysis. Can J Anaesth. 2014 May;61(5):452-79. doi: 10.1007/s12630-014-0135-8. Epub 2014 Mar 19.
- Smetkin AA, Hussain A, Kuzkov VV, Bjertnaes LJ, Kirov MY. Validation of cardiac output monitoring based on uncalibrated pulse contour analysis vs transpulmonary thermodilution during off-pump coronary artery bypass grafting. Br J Anaesth. 2014 Jun;112(6):1024-31. doi: 10.1093/bja/aet489. Epub 2014 Feb 13.
- Huang L, Critchley LA. An assessment of two Doppler-based monitors to track cardiac output changes in anaesthetised patients undergoing major surgery. Anaesth Intensive Care. 2014 Sep;42(5):631-9. doi: 10.1177/0310057X1404200514.
- Singer M. Oesophageal Doppler. Curr Opin Crit Care. 2009 Jun;15(3):244-8. doi: 10.1097/MCC.0b013e32832b7083.
- Broch O, Bein B, Gruenewald M, Masing S, Huenges K, Haneya A, Steinfath M, Renner J. Accuracy of Cardiac Output by Nine Different Pulse Contour Algorithms in Cardiac Surgery Patients: A Comparison with Transpulmonary Thermodilution. Biomed Res Int. 2016;2016:3468015. doi: 10.1155/2016/3468015. Epub 2016 Dec 28.
연구 기록 날짜
연구 주요 날짜
연구 시작
기본 완료 (실제)
연구 완료 (실제)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (추정)
연구 기록 업데이트
마지막 업데이트 게시됨 (추정)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
- AZ-138
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .
심 박출량에 대한 임상 시험
-
Near East University, TurkeyAl-Ahli Hospital, Hebron모집하지 않고 적극적으로DVT 예방 | DVT - 심부 정맥 혈전증 | 심장 온펌프 수술 | DVT 예방 | On-pump Cardiac Surgery - Prevention - Intervention - Experimental Group - Control Group - Incidence - Complications | 간호 관리 프로토콜키프로스
Cardiac output measurement에 대한 임상 시험
-
Weill Medical College of Cornell UniversityMedistim ASA모병CABG | 심장 질환 | 혈류 | CABG 그래프트 무결성 | 이행시간 유량 측정미국
-
Medtronic Cardiac Ablation Solutions완전한
-
Medtronic Cardiac Rhythm and Heart FailureMedtronic International Trading Sarl완전한
-
Uppsala University HospitalMedtronic; Swedish Heart Lung Foundation알려지지 않은
-
Boston Scientific Corporation모집하지 않고 적극적으로빈맥, 심실 | 부정맥, 심실미국, 스페인, 이탈리아, 영국, 네덜란드, 프랑스, 체코, 오스트리아, 캐나다
-
Medtronic Cardiac Ablation Solutions완전한
-
Respicardia, Inc.완전한