Cardiac Output by Nine Different Pulse Contour Algorithms
Estimation of Cardiac Output by Nine Different Pulse Contour Algorithms Compared With Transpulmonary Thermodilution
研究概览
详细说明
After induction of anesthesia, a central venous catheter and a transpulmonary thermodilution catheter (Pulsion Medical Systems, Munich, Germany) are introduced in the right internal jugular vein and in the femoral artery, respectively. The thermodilution catheter is connected to a PiCCO2 monitor (Software version 1.3.0.8). Thereafter, placement of an esophageal doppler probe is performed and the probe is connected to a unique Monitoring System (Deltex Medical, Chichester, UK) with nine different pulse contour algorithms. Cardiac Output by esophageal doppler is used to calibrate the nine different pulse contour algorithms.
After induction of anesthesia and establishment of all monitoring devices, a passive leg raising maneouvre (PLR) is performed and hemodynamic variables including CO by transpulmonary thermodilution (COTPTD) and CO by nine different pulse contour algorithms (COX1-9) are recorded before, during and after PLR. Subsequently, measurements of COTPTD and COX1-9 are carried out every 10 minutes until the beginning of CPB. Fifteen minutes after weaning from cardiopulmonary bypass calibration of nine different pulse contour algorithms by esophageal doppler are performed again and measurements of CITPTD and CIPFX are restarted up to the end of the surgical Intervention.
研究类型
注册 (实际的)
阶段
- 不适用
联系人和位置
学习地点
-
-
-
Hamburg、德国、20099
- Berthold Bein
-
-
参与标准
资格标准
适合学习的年龄
接受健康志愿者
有资格学习的性别
描述
Inclusion Criteria:
- Patients > 18 years of age with a left ventricular ejection fraction ≥ 0.5.
- Patients undergoing coronary artery bypass grafting.
Exclusion Criteria:
- Patients <18 years of age and with a left ventricular ejection fraction ≤0.5 are not considered for the study.
- Emergency procedures and patients with hemodynamic instability requiring continuous pharmacologic support, intracardiac shunts, severe aortic-, tricuspid- or mitral stenosis or insufficiency and mechanical circulatory support were also excluded.
学习计划
研究是如何设计的?
设计细节
- 分配:不适用
- 介入模型:单组作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
其他:Cardiac output measurement
|
Measurement of cardiac output by transpulmonary thermodilution, nine different pulse contour algorithms and esophageal doppler before, during and after a PLR-maneouvre and every 10 minutes before and after cardiopulmonary Bypass.
|
研究衡量的是什么?
主要结果指标
结果测量 |
大体时间 |
|---|---|
|
Accuracy of cardiac output in l/min by nine different pulse contour algorithms compared with transpulmonary thermodilution
大体时间:After induction of anesthesia until the end of surgery
|
After induction of anesthesia until the end of surgery
|
合作者和调查者
调查人员
- 首席研究员:Berthold Bein, MD, PhD、Asklepios Klinik St. Georg
出版物和有用的链接
一般刊物
- Critchley LA, Lee A, Ho AM. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg. 2010 Nov;111(5):1180-92. doi: 10.1213/ANE.0b013e3181f08a5b. Epub 2010 Aug 24.
- Suehiro K, Tanaka K, Funao T, Matsuura T, Mori T, Nishikawa K. Systemic vascular resistance has an impact on the reliability of the Vigileo-FloTrac system in measuring cardiac output and tracking cardiac output changes. Br J Anaesth. 2013 Aug;111(2):170-7. doi: 10.1093/bja/aet022. Epub 2013 Mar 10.
- Schloglhofer T, Gilly H, Schima H. Semi-invasive measurement of cardiac output based on pulse contour: a review and analysis. Can J Anaesth. 2014 May;61(5):452-79. doi: 10.1007/s12630-014-0135-8. Epub 2014 Mar 19.
- Smetkin AA, Hussain A, Kuzkov VV, Bjertnaes LJ, Kirov MY. Validation of cardiac output monitoring based on uncalibrated pulse contour analysis vs transpulmonary thermodilution during off-pump coronary artery bypass grafting. Br J Anaesth. 2014 Jun;112(6):1024-31. doi: 10.1093/bja/aet489. Epub 2014 Feb 13.
- Huang L, Critchley LA. An assessment of two Doppler-based monitors to track cardiac output changes in anaesthetised patients undergoing major surgery. Anaesth Intensive Care. 2014 Sep;42(5):631-9. doi: 10.1177/0310057X1404200514.
- Singer M. Oesophageal Doppler. Curr Opin Crit Care. 2009 Jun;15(3):244-8. doi: 10.1097/MCC.0b013e32832b7083.
- Broch O, Bein B, Gruenewald M, Masing S, Huenges K, Haneya A, Steinfath M, Renner J. Accuracy of Cardiac Output by Nine Different Pulse Contour Algorithms in Cardiac Surgery Patients: A Comparison with Transpulmonary Thermodilution. Biomed Res Int. 2016;2016:3468015. doi: 10.1155/2016/3468015. Epub 2016 Dec 28.
研究记录日期
研究主要日期
学习开始
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (估计)
研究记录更新
最后更新发布 (估计)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- AZ-138
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.