- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT02438228
Cardiac Output by Nine Different Pulse Contour Algorithms
Estimation of Cardiac Output by Nine Different Pulse Contour Algorithms Compared With Transpulmonary Thermodilution
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Gedetailleerde beschrijving
After induction of anesthesia, a central venous catheter and a transpulmonary thermodilution catheter (Pulsion Medical Systems, Munich, Germany) are introduced in the right internal jugular vein and in the femoral artery, respectively. The thermodilution catheter is connected to a PiCCO2 monitor (Software version 1.3.0.8). Thereafter, placement of an esophageal doppler probe is performed and the probe is connected to a unique Monitoring System (Deltex Medical, Chichester, UK) with nine different pulse contour algorithms. Cardiac Output by esophageal doppler is used to calibrate the nine different pulse contour algorithms.
After induction of anesthesia and establishment of all monitoring devices, a passive leg raising maneouvre (PLR) is performed and hemodynamic variables including CO by transpulmonary thermodilution (COTPTD) and CO by nine different pulse contour algorithms (COX1-9) are recorded before, during and after PLR. Subsequently, measurements of COTPTD and COX1-9 are carried out every 10 minutes until the beginning of CPB. Fifteen minutes after weaning from cardiopulmonary bypass calibration of nine different pulse contour algorithms by esophageal doppler are performed again and measurements of CITPTD and CIPFX are restarted up to the end of the surgical Intervention.
Studietype
Inschrijving (Werkelijk)
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
-
Hamburg, Duitsland, 20099
- Berthold Bein
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Patients > 18 years of age with a left ventricular ejection fraction ≥ 0.5.
- Patients undergoing coronary artery bypass grafting.
Exclusion Criteria:
- Patients <18 years of age and with a left ventricular ejection fraction ≤0.5 are not considered for the study.
- Emergency procedures and patients with hemodynamic instability requiring continuous pharmacologic support, intracardiac shunts, severe aortic-, tricuspid- or mitral stenosis or insufficiency and mechanical circulatory support were also excluded.
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Toewijzing: NVT
- Interventioneel model: Opdracht voor een enkele groep
- Masker: Geen (open label)
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Ander: Cardiac output measurement
|
Measurement of cardiac output by transpulmonary thermodilution, nine different pulse contour algorithms and esophageal doppler before, during and after a PLR-maneouvre and every 10 minutes before and after cardiopulmonary Bypass.
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Tijdsspanne |
|---|---|
|
Accuracy of cardiac output in l/min by nine different pulse contour algorithms compared with transpulmonary thermodilution
Tijdsspanne: After induction of anesthesia until the end of surgery
|
After induction of anesthesia until the end of surgery
|
Medewerkers en onderzoekers
Onderzoekers
- Hoofdonderzoeker: Berthold Bein, MD, PhD, Asklepios Klinik St. Georg
Publicaties en nuttige links
Algemene publicaties
- Critchley LA, Lee A, Ho AM. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg. 2010 Nov;111(5):1180-92. doi: 10.1213/ANE.0b013e3181f08a5b. Epub 2010 Aug 24.
- Suehiro K, Tanaka K, Funao T, Matsuura T, Mori T, Nishikawa K. Systemic vascular resistance has an impact on the reliability of the Vigileo-FloTrac system in measuring cardiac output and tracking cardiac output changes. Br J Anaesth. 2013 Aug;111(2):170-7. doi: 10.1093/bja/aet022. Epub 2013 Mar 10.
- Schloglhofer T, Gilly H, Schima H. Semi-invasive measurement of cardiac output based on pulse contour: a review and analysis. Can J Anaesth. 2014 May;61(5):452-79. doi: 10.1007/s12630-014-0135-8. Epub 2014 Mar 19.
- Smetkin AA, Hussain A, Kuzkov VV, Bjertnaes LJ, Kirov MY. Validation of cardiac output monitoring based on uncalibrated pulse contour analysis vs transpulmonary thermodilution during off-pump coronary artery bypass grafting. Br J Anaesth. 2014 Jun;112(6):1024-31. doi: 10.1093/bja/aet489. Epub 2014 Feb 13.
- Huang L, Critchley LA. An assessment of two Doppler-based monitors to track cardiac output changes in anaesthetised patients undergoing major surgery. Anaesth Intensive Care. 2014 Sep;42(5):631-9. doi: 10.1177/0310057X1404200514.
- Singer M. Oesophageal Doppler. Curr Opin Crit Care. 2009 Jun;15(3):244-8. doi: 10.1097/MCC.0b013e32832b7083.
- Broch O, Bein B, Gruenewald M, Masing S, Huenges K, Haneya A, Steinfath M, Renner J. Accuracy of Cardiac Output by Nine Different Pulse Contour Algorithms in Cardiac Surgery Patients: A Comparison with Transpulmonary Thermodilution. Biomed Res Int. 2016;2016:3468015. doi: 10.1155/2016/3468015. Epub 2016 Dec 28.
Studie record data
Bestudeer belangrijke data
Studie start
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Updates van studierecords
Laatste update geplaatst (Schatting)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Andere studie-ID-nummers
- AZ-138
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .
Klinische onderzoeken op Cardiale output
-
University of LiegeVoltooidLow Cardiac Output Syndroom na hartchirurgie bij volwassenen
-
Klinikum LudwigshafenKlinikum der Stadt Ludwigshafen, Department of Anesthesiology and Intensive... en andere medewerkersVoltooid
-
Università Vita-Salute San RaffaeleVoltooidLow Cardiac Output-syndroomItalië, Brazilië, Russische Federatie
-
Tenax Therapeutics, Inc.VoltooidCoronaire bypass-transplantatie | Low Cardiac Output-syndroom | MitralisklepoperatieCanada, Verenigde Staten
-
Cliniques universitaires Saint-Luc- Université...VoltooidLow Cardiac Output-syndroom | Aangeboren hart- en vaatziektenBelgië
-
University of Sao Paulo General HospitalCoordenação de Aperfeiçoamento de Pessoal de Nível Superior.WervingLow Cardiac Output-syndroomBrazilië
-
Ludwig Boltzmann GesellschaftOnbekendLow Cardiac Output-syndroomOostenrijk
-
Università Vita-Salute San RaffaeleWerving
-
Institute for Clinical and Experimental MedicineWervingKetose | Acuut hartfalen | Hemodynamische instabiliteit | Low Cardiac Output-syndroomTsjechië
-
Fundacion para la Investigacion Biomedica del Hospital...Fondo de Investigacion Sanitaria; Hospital Universitario La PazVoltooid
Klinische onderzoeken op Cardiac output measurement
-
Santa Barbara Cottage HospitalVoltooidPulmonale hypertensieVerenigde Staten
-
Coventry UniversityNewcastle University; University of Cambridge; University of Florence; University... en andere medewerkersNog niet aan het werven
-
University of California, San FranciscoNorthern California Institute of Research and Education; San Francisco Veterans... en andere medewerkersVoltooidMyocardinfarct | Myocardiale ischemieVerenigde Staten
-
McMaster UniversityVoltooidKritieke ziekte | Hemodynamisch stabielCanada
-
Hospital for Special Surgery, New YorkVoltooidCerebrale ischemieVerenigde Staten
-
Assistance Publique - Hôpitaux de ParisINSERM UMR-942, Paris, FranceWervingBloeddruk | Chirurgie | Narcose | Intensieve zorg | Hemodynamische instabiliteit | Cardiale output | Interventionele Radiologie | OrgaanfalenFrankrijk
-
Weill Medical College of Cornell UniversityMedistim ASAWervingCABG | Hartziekte | Bloedstroom | CABG-transplantaatintegriteit | Transittijd FlowmetingVerenigde Staten
-
Yale UniversityVoltooid
-
Poitiers University HospitalVoltooidMeting van het hartminuutvolumeFrankrijk
-
Tung Wah CollegeWervingCoronaire hartziekte (CHZ)Hongkong