Cardiac Output by Nine Different Pulse Contour Algorithms
Estimation of Cardiac Output by Nine Different Pulse Contour Algorithms Compared With Transpulmonary Thermodilution
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
After induction of anesthesia, a central venous catheter and a transpulmonary thermodilution catheter (Pulsion Medical Systems, Munich, Germany) are introduced in the right internal jugular vein and in the femoral artery, respectively. The thermodilution catheter is connected to a PiCCO2 monitor (Software version 1.3.0.8). Thereafter, placement of an esophageal doppler probe is performed and the probe is connected to a unique Monitoring System (Deltex Medical, Chichester, UK) with nine different pulse contour algorithms. Cardiac Output by esophageal doppler is used to calibrate the nine different pulse contour algorithms.
After induction of anesthesia and establishment of all monitoring devices, a passive leg raising maneouvre (PLR) is performed and hemodynamic variables including CO by transpulmonary thermodilution (COTPTD) and CO by nine different pulse contour algorithms (COX1-9) are recorded before, during and after PLR. Subsequently, measurements of COTPTD and COX1-9 are carried out every 10 minutes until the beginning of CPB. Fifteen minutes after weaning from cardiopulmonary bypass calibration of nine different pulse contour algorithms by esophageal doppler are performed again and measurements of CITPTD and CIPFX are restarted up to the end of the surgical Intervention.
Tipo di studio
Iscrizione (Effettivo)
Fase
- Non applicabile
Contatti e Sedi
Luoghi di studio
-
-
-
Hamburg, Germania, 20099
- Berthold Bein
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Inclusion Criteria:
- Patients > 18 years of age with a left ventricular ejection fraction ≥ 0.5.
- Patients undergoing coronary artery bypass grafting.
Exclusion Criteria:
- Patients <18 years of age and with a left ventricular ejection fraction ≤0.5 are not considered for the study.
- Emergency procedures and patients with hemodynamic instability requiring continuous pharmacologic support, intracardiac shunts, severe aortic-, tricuspid- or mitral stenosis or insufficiency and mechanical circulatory support were also excluded.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Altro: Cardiac output measurement
|
Measurement of cardiac output by transpulmonary thermodilution, nine different pulse contour algorithms and esophageal doppler before, during and after a PLR-maneouvre and every 10 minutes before and after cardiopulmonary Bypass.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Lasso di tempo |
|---|---|
|
Accuracy of cardiac output in l/min by nine different pulse contour algorithms compared with transpulmonary thermodilution
Lasso di tempo: After induction of anesthesia until the end of surgery
|
After induction of anesthesia until the end of surgery
|
Collaboratori e investigatori
Investigatori
- Investigatore principale: Berthold Bein, MD, PhD, Asklepios Klinik St. Georg
Pubblicazioni e link utili
Pubblicazioni generali
- Critchley LA, Lee A, Ho AM. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg. 2010 Nov;111(5):1180-92. doi: 10.1213/ANE.0b013e3181f08a5b. Epub 2010 Aug 24.
- Suehiro K, Tanaka K, Funao T, Matsuura T, Mori T, Nishikawa K. Systemic vascular resistance has an impact on the reliability of the Vigileo-FloTrac system in measuring cardiac output and tracking cardiac output changes. Br J Anaesth. 2013 Aug;111(2):170-7. doi: 10.1093/bja/aet022. Epub 2013 Mar 10.
- Schloglhofer T, Gilly H, Schima H. Semi-invasive measurement of cardiac output based on pulse contour: a review and analysis. Can J Anaesth. 2014 May;61(5):452-79. doi: 10.1007/s12630-014-0135-8. Epub 2014 Mar 19.
- Smetkin AA, Hussain A, Kuzkov VV, Bjertnaes LJ, Kirov MY. Validation of cardiac output monitoring based on uncalibrated pulse contour analysis vs transpulmonary thermodilution during off-pump coronary artery bypass grafting. Br J Anaesth. 2014 Jun;112(6):1024-31. doi: 10.1093/bja/aet489. Epub 2014 Feb 13.
- Huang L, Critchley LA. An assessment of two Doppler-based monitors to track cardiac output changes in anaesthetised patients undergoing major surgery. Anaesth Intensive Care. 2014 Sep;42(5):631-9. doi: 10.1177/0310057X1404200514.
- Singer M. Oesophageal Doppler. Curr Opin Crit Care. 2009 Jun;15(3):244-8. doi: 10.1097/MCC.0b013e32832b7083.
- Broch O, Bein B, Gruenewald M, Masing S, Huenges K, Haneya A, Steinfath M, Renner J. Accuracy of Cardiac Output by Nine Different Pulse Contour Algorithms in Cardiac Surgery Patients: A Comparison with Transpulmonary Thermodilution. Biomed Res Int. 2016;2016:3468015. doi: 10.1155/2016/3468015. Epub 2016 Dec 28.
Studiare le date dei record
Studia le date principali
Inizio studio
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Stima)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Altri numeri di identificazione dello studio
- AZ-138
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .
Prove cliniche su Gittata cardiaca
-
Assiut UniversityNon ancora reclutamentoCardiac CT TOF
-
Rush University Medical CenterCompletatoAdvanced Cardiac Life Support, rianimazione cardiopolmonare, volume corrente, ventilazione manualeStati Uniti
Prove cliniche su Cardiac output measurement
-
Centre Chirurgical Marie LannelongueSconosciuto
-
MediBeaconNon ancora reclutamentoVelocità di filtrazione glomerulareStati Uniti
-
University Health Network, TorontoHumber River HospitalAttivo, non reclutante
-
St. Luke's-Roosevelt Hospital CenterCompletato
-
Seattle Institute for Cardiac ResearchCardiac Science Corporation.CompletatoFibrillazione atriale | Sincope | Tachicardia sopraventricolare | Pre-sincopeStati Uniti, Nuova Zelanda
-
St Elizabeth HealthcareCompletatoSospetta aritmiaStati Uniti
-
University Health Network, TorontoCanadian Institutes of Health Research (CIHR)Non ancora reclutamentoMalattie cardiache | Malattia cardiovascolare | Conoscenza della salute, atteggiamenti, pratica | Comportamento, Salute
-
Medtronic Cardiac Rhythm and Heart FailureCompletatoTachicardia, rientro nodale atrioventricolareStati Uniti
-
Medtronic Cardiac Rhythm and Heart FailureTerminato
-
Medtronic Cardiac Rhythm and Heart FailureCompletatoScompenso cardiaco Classe NYHA II | Insufficienza cardiaca Classe NYHA IIIStati Uniti