Cardiac Output by Nine Different Pulse Contour Algorithms
Estimation of Cardiac Output by Nine Different Pulse Contour Algorithms Compared With Transpulmonary Thermodilution
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
After induction of anesthesia, a central venous catheter and a transpulmonary thermodilution catheter (Pulsion Medical Systems, Munich, Germany) are introduced in the right internal jugular vein and in the femoral artery, respectively. The thermodilution catheter is connected to a PiCCO2 monitor (Software version 1.3.0.8). Thereafter, placement of an esophageal doppler probe is performed and the probe is connected to a unique Monitoring System (Deltex Medical, Chichester, UK) with nine different pulse contour algorithms. Cardiac Output by esophageal doppler is used to calibrate the nine different pulse contour algorithms.
After induction of anesthesia and establishment of all monitoring devices, a passive leg raising maneouvre (PLR) is performed and hemodynamic variables including CO by transpulmonary thermodilution (COTPTD) and CO by nine different pulse contour algorithms (COX1-9) are recorded before, during and after PLR. Subsequently, measurements of COTPTD and COX1-9 are carried out every 10 minutes until the beginning of CPB. Fifteen minutes after weaning from cardiopulmonary bypass calibration of nine different pulse contour algorithms by esophageal doppler are performed again and measurements of CITPTD and CIPFX are restarted up to the end of the surgical Intervention.
Type d'étude
Inscription (Réel)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
-
Hamburg, Allemagne, 20099
- Berthold Bein
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- Patients > 18 years of age with a left ventricular ejection fraction ≥ 0.5.
- Patients undergoing coronary artery bypass grafting.
Exclusion Criteria:
- Patients <18 years of age and with a left ventricular ejection fraction ≤0.5 are not considered for the study.
- Emergency procedures and patients with hemodynamic instability requiring continuous pharmacologic support, intracardiac shunts, severe aortic-, tricuspid- or mitral stenosis or insufficiency and mechanical circulatory support were also excluded.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Répartition: N / A
- Modèle interventionnel: Affectation à un seul groupe
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Autre: Cardiac output measurement
|
Measurement of cardiac output by transpulmonary thermodilution, nine different pulse contour algorithms and esophageal doppler before, during and after a PLR-maneouvre and every 10 minutes before and after cardiopulmonary Bypass.
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Délai |
|---|---|
|
Accuracy of cardiac output in l/min by nine different pulse contour algorithms compared with transpulmonary thermodilution
Délai: After induction of anesthesia until the end of surgery
|
After induction of anesthesia until the end of surgery
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Chercheur principal: Berthold Bein, MD, PhD, Asklepios Klinik St. Georg
Publications et liens utiles
Publications générales
- Critchley LA, Lee A, Ho AM. A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg. 2010 Nov;111(5):1180-92. doi: 10.1213/ANE.0b013e3181f08a5b. Epub 2010 Aug 24.
- Suehiro K, Tanaka K, Funao T, Matsuura T, Mori T, Nishikawa K. Systemic vascular resistance has an impact on the reliability of the Vigileo-FloTrac system in measuring cardiac output and tracking cardiac output changes. Br J Anaesth. 2013 Aug;111(2):170-7. doi: 10.1093/bja/aet022. Epub 2013 Mar 10.
- Schloglhofer T, Gilly H, Schima H. Semi-invasive measurement of cardiac output based on pulse contour: a review and analysis. Can J Anaesth. 2014 May;61(5):452-79. doi: 10.1007/s12630-014-0135-8. Epub 2014 Mar 19.
- Smetkin AA, Hussain A, Kuzkov VV, Bjertnaes LJ, Kirov MY. Validation of cardiac output monitoring based on uncalibrated pulse contour analysis vs transpulmonary thermodilution during off-pump coronary artery bypass grafting. Br J Anaesth. 2014 Jun;112(6):1024-31. doi: 10.1093/bja/aet489. Epub 2014 Feb 13.
- Huang L, Critchley LA. An assessment of two Doppler-based monitors to track cardiac output changes in anaesthetised patients undergoing major surgery. Anaesth Intensive Care. 2014 Sep;42(5):631-9. doi: 10.1177/0310057X1404200514.
- Singer M. Oesophageal Doppler. Curr Opin Crit Care. 2009 Jun;15(3):244-8. doi: 10.1097/MCC.0b013e32832b7083.
- Broch O, Bein B, Gruenewald M, Masing S, Huenges K, Haneya A, Steinfath M, Renner J. Accuracy of Cardiac Output by Nine Different Pulse Contour Algorithms in Cardiac Surgery Patients: A Comparison with Transpulmonary Thermodilution. Biomed Res Int. 2016;2016:3468015. doi: 10.1155/2016/3468015. Epub 2016 Dec 28.
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Estimation)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Autres numéros d'identification d'étude
- AZ-138
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .
Essais cliniques sur Cardiac output measurement
-
St. Luke's-Roosevelt Hospital CenterComplété
-
University of California, San FranciscoComplétéAccident vasculaire cérébralÉtats-Unis
-
Hôpital Léon BérardCentre Hospitalier Toulon; Groupement des Hôpitaux de l'Institut Catholique...ComplétéBénéficiaires d'une transplantation cardiaque
-
University Health Network, TorontoCanadian Institutes of Health Research (CIHR)Pas encore de recrutementMaladies cardiaques | Maladies cardiovasculaires | Connaissances, attitudes, pratique de la santé | Comportement, Santé
-
Medtronic Cardiac Rhythm and Heart FailureRésiliéInsuffisance cardiaquePays-Bas
-
Respicardia, Inc.ComplétéApnée du sommeil | Troubles respiratoires du sommeil | Respiration périodique | Apnée centrale du sommeil | Respiration de Cheyne StokesÉtats-Unis, Pologne, Allemagne, Italie
-
University of MinnesotaRésiliéFibrillation ventriculaire | Crise cardiaque | Arrêt cardiaque hors hôpital | Complication de l'oxygénation de la membrane extracorporelle | Tachycardie ventriculaire sans poulsÉtats-Unis
-
Medtronic Cardiac Rhythm and Heart FailureComplété
-
University of Massachusetts, WorcesterNational Heart, Lung, and Blood Institute (NHLBI); Brigham and Women's Hospital et autres collaborateursComplétéAccident vasculaire cérébral | Fibrillation auriculaireÉtats-Unis