- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT04904640
Biomechanical Reconstruction of Three Different Hip Stem Designs in Hip Dysplasia Using a 3D CT-based Planning Software (CTdevice)
Evaluation of the Reconstruction of Biomechanical Parameters Provided by Three Different Hip Stem Designs in Developmental Hip Dysplasia Using a 3D CT-based Software for Surgical Planning
연구 개요
상세 설명
Pre-operative planning in hip arthroplasty with dedicated software is a useful guide to provide a better reconstruction of the biomechanical parameters of the replaced hip and to optimize the choice of component, improving the geometric understanding of the hip anatomy and the interaction between the native morphological structure and the prosthetic component.
The use of a 3D CT-based software for pre-operative planning may provide a better knowledge of the hip anatomy, simulating the biomechanical parameters more closely than a 2D X-ray-based software. In addition, it is the only way to anticipate the correct interaction between the prosthetic components, or the combined anteversion, a key factor in preventing implant instability.
Severe hip deformities, like developmental hip dysplasia, may not be adequately reconstructed by every implant and 3D pre-operative CT may increase the three-dimensional anatomical knowledge of the hip, improving the choice of the correct implant and possibly reducing the possible consequences of intra and post-operative complications.
Therefore, the purpose of this study is to pre-operatively plan, in a random series of 200 native pelvis and thigh CT scans performed in patients with hip dysplasia, 3 different types of hip stem designs using the 3D Hip-Op software, with the aim of analyzing, on the CT simulations, the percentage of adequate reconstruction of the optimal biomechanical parameters (combined anteversion between 25°-50°, global offset not inferior to 12% of the native offset, leg lengthening not superior to 3 cm, sagittal and coronal tilt not superior to +/-5°, canal filling not inferior to 80%). The percentage of every stem design providing the optimal reconstruction in dysplastic hips (all the 5 parameters matched) will be assessed. The single parameters, especially the combined anteversion, the offset restoration and the leg lengthening, will be assessed for every simulation.
연구 유형
등록 (실제)
연락처 및 위치
연구 장소
-
-
-
Bologna, 이탈리아, 40136
- Chirurgia Protesica e dei Reimpianti di Anca e Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
-
-
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
샘플링 방법
연구 인구
설명
Inclusion Criteria:
- definition of developmental hip dysplasia according to Wiberg (center edge angle <20°)
- pre-operative CT scan extended from the fourth lumbar vertebra to the tibial plateaus
Exclusion Criteria:
- other types of hip pathologies
- inadequate Ct scans
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
코호트 및 개입
그룹/코호트 |
개입 / 치료 |
|---|---|
|
CLS stem
CLS Zimmer stem implantation (single wedge, tapered stem) using the 3D CT based software for surgical pre-operative planning
|
In every hip (with appropriate CT scan), 3 different stem designs will be positioned using a 3D Ct based software for surgical pre-operative planning.
|
|
Wagner cone stem
Wagner cone Zimmer stem implantation (conical tapered stem) using the 3D CT based software for surgical pre-operative planning
|
In every hip (with appropriate CT scan), 3 different stem designs will be positioned using a 3D Ct based software for surgical pre-operative planning.
|
|
Aptafix stem
Aptafix Ortho stem implantation (anatomical stem) using the 3D CT based software for surgical pre-operative planning
|
In every hip (with appropriate CT scan), 3 different stem designs will be positioned using a 3D Ct based software for surgical pre-operative planning.
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Correct Reconstruction CLS
기간: Day 0
|
Percentage of hips correctly reconstructed using CLS stem: the correctly reconstructed hip should have combined anteversion between 25° and 50°, global offset not inferior to 12% of the native offset, leg lengthening not superior to 3 cm, sagittal and coronal tilt not superior to +/-5°, canal filling not inferior to 80% (all the 5 parameters should be present at the same time).
Minimum-maximum values (as percentage %): 0-100.
100 is the best result, 0 the worst
|
Day 0
|
|
Correct Reconstruction Wagner Cone
기간: Day 0
|
Percentage of hips correctly reconstructed using CLS stem: the correctly reconstructed hip should have combined anteversion between 25° and 50°, global offset not inferior to 12% of the native offset, leg lengthening not superior to 3 cm, sagittal and coronal tilt not superior to +/-5°, canal filling not inferior to 80% (all the 5 parameters should be present at the same time).
Minimum-maximum values (as percentage %): 0-100.
100 is the best result, 0 the worst
|
Day 0
|
|
Correct Reconstruction Aptafix
기간: Day 0
|
Percentage of hips correctly reconstructed using CLS stem: the correctly reconstructed hip should have combined anteversion between 25° and 50°, global offset not inferior to 12% of the native offset, leg lengthening not superior to 3 cm, sagittal and coronal tilt not superior to +/-5°, canal filling not inferior to 80% (all the 5 parameters should be present at the same time).
Minimum-maximum values (as percentage %): 0-100.
100 is the best result, 0 the worst
|
Day 0
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Combined Anteversion CLS
기간: Day 0
|
Percentage of hips with adequate combined anteversion according to Dorr (25-50°) and Widmer (<37°) using CLS stems.
Minimum-maximum values (as percentage %): 0-100.
100 is the best result, 0 is the worst
|
Day 0
|
|
Combined Anteversion Wagner Cone
기간: Day 0
|
Percentage of hips with adequate combined anteversion according to Dorr (25-50°) and Widmer (<37°) using CLS stems.
Minimum-maximum values (as percentage %): 0-100.
100 is the best result, 0 is the worst
|
Day 0
|
|
Combined Anteversion Aptafix
기간: Day 0
|
Percentage of hips with adequate combined anteversion according to Dorr (25-50°) and Widmer (<37°) using CLS stems.
Minimum-maximum values (as percentage %): 0-100.
100 is the best result, 0 is the worst
|
Day 0
|
|
Offset CLS
기간: Day 0
|
Percentage of hips with acetabular+femoral offset not inferior to 12% of the native value using CLS stems.
Minimum-maximum values (as percentage %): 0-100.
100 is the best result, 0 is the worst
|
Day 0
|
|
Offset Wagner Cone
기간: Day 0
|
Percentage of hips with acetabular+femoral offset not inferior to 12% of the native value using CLS stems.
Minimum-maximum values (as percentage %): 0-100.
100 is the best result, 0 is the worst
|
Day 0
|
|
Offset Aptafix
기간: Day 0
|
Percentage of hips with acetabular+femoral offset not inferior to 12% of the native value using CLS stems.
Minimum-maximum values (as percentage %): 0-100.
100 is the best result, 0 is the worst
|
Day 0
|
|
Leg Lengthening CLS
기간: Day 0
|
Percentage of hips with leg lengthening not superior to 3 cm using CLS stems.
Minimum-maximum values (as percentages %): 0-100.
100 is the best result, 0 is the worst
|
Day 0
|
|
Leg Lengthening Wagner Cone
기간: Day 0
|
Percentage of hips with leg lengthening not superior to 3 cm using CLS stems.
Minimum-maximum values (as percentages %): 0-100.
100 is the best result, 0 is the worst
|
Day 0
|
|
Leg Lengthening Aptafix
기간: Day 0
|
Percentage of hips with leg lengthening not superior to 3 cm using CLS stems.
Minimum-maximum values (as percentages %): 0-100.
100 is the best result, 0 is the worst
|
Day 0
|
공동 작업자 및 조사자
수사관
- 연구 책임자: Francesco Traina, Professor, IRCCS Istituto Ortopedico Rizzoli
간행물 및 유용한 링크
일반 간행물
- Taniguchi N, Jinno T, Koga D, Hagino T, Okawa A, Haro H. Cementless Hip Stem Anteversion in the Dysplastic Hip: A Comparison of Tapered Wedge vs Metaphyseal Filling. J Arthroplasty. 2017 May;32(5):1547-1552. doi: 10.1016/j.arth.2016.12.020. Epub 2016 Dec 22.
- Argenson JN, Ryembault E, Flecher X, Brassart N, Parratte S, Aubaniac JM. Three-dimensional anatomy of the hip in osteoarthritis after developmental dysplasia. J Bone Joint Surg Br. 2005 Sep;87(9):1192-6. doi: 10.1302/0301-620X.87B9.15928.
- Sugano N, Takao M, Sakai T, Nishii T, Miki H. Does CT-based navigation improve the long-term survival in ceramic-on-ceramic THA? Clin Orthop Relat Res. 2012 Nov;470(11):3054-9. doi: 10.1007/s11999-012-2378-4.
- Castagnini F, Valente G, Crimi G, Taddei F, Bordini B, Stea S, Toni A. Component positioning and ceramic damage in cementless ceramic-on-ceramic total hip arthroplasty. J Orthop Sci. 2019 Jul;24(4):643-651. doi: 10.1016/j.jos.2018.12.011. Epub 2019 Jan 4.
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
기본 완료 (실제)
연구 완료 (실제)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
추가 관련 MeSH 약관
기타 연구 ID 번호
- 29/2021/Oss/IOR
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .