Biomechanical Reconstruction of Three Different Hip Stem Designs in Hip Dysplasia Using a 3D CT-based Planning Software (CTdevice)
Evaluation of the Reconstruction of Biomechanical Parameters Provided by Three Different Hip Stem Designs in Developmental Hip Dysplasia Using a 3D CT-based Software for Surgical Planning
Přehled studie
Detailní popis
Pre-operative planning in hip arthroplasty with dedicated software is a useful guide to provide a better reconstruction of the biomechanical parameters of the replaced hip and to optimize the choice of component, improving the geometric understanding of the hip anatomy and the interaction between the native morphological structure and the prosthetic component.
The use of a 3D CT-based software for pre-operative planning may provide a better knowledge of the hip anatomy, simulating the biomechanical parameters more closely than a 2D X-ray-based software. In addition, it is the only way to anticipate the correct interaction between the prosthetic components, or the combined anteversion, a key factor in preventing implant instability.
Severe hip deformities, like developmental hip dysplasia, may not be adequately reconstructed by every implant and 3D pre-operative CT may increase the three-dimensional anatomical knowledge of the hip, improving the choice of the correct implant and possibly reducing the possible consequences of intra and post-operative complications.
Therefore, the purpose of this study is to pre-operatively plan, in a random series of 200 native pelvis and thigh CT scans performed in patients with hip dysplasia, 3 different types of hip stem designs using the 3D Hip-Op software, with the aim of analyzing, on the CT simulations, the percentage of adequate reconstruction of the optimal biomechanical parameters (combined anteversion between 25°-50°, global offset not inferior to 12% of the native offset, leg lengthening not superior to 3 cm, sagittal and coronal tilt not superior to +/-5°, canal filling not inferior to 80%). The percentage of every stem design providing the optimal reconstruction in dysplastic hips (all the 5 parameters matched) will be assessed. The single parameters, especially the combined anteversion, the offset restoration and the leg lengthening, will be assessed for every simulation.
Typ studie
Zápis (Aktuální)
Kontakty a umístění
Studijní místa
-
-
-
Bologna, Itálie, 40136
- Chirurgia Protesica e dei Reimpianti di Anca e Ginocchio, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Metoda odběru vzorků
Studijní populace
Popis
Inclusion Criteria:
- definition of developmental hip dysplasia according to Wiberg (center edge angle <20°)
- pre-operative CT scan extended from the fourth lumbar vertebra to the tibial plateaus
Exclusion Criteria:
- other types of hip pathologies
- inadequate Ct scans
Studijní plán
Jak je studie koncipována?
Detaily designu
Kohorty a intervence
Skupina / kohorta |
Intervence / Léčba |
|---|---|
|
CLS stem
CLS Zimmer stem implantation (single wedge, tapered stem) using the 3D CT based software for surgical pre-operative planning
|
In every hip (with appropriate CT scan), 3 different stem designs will be positioned using a 3D Ct based software for surgical pre-operative planning.
|
|
Wagner cone stem
Wagner cone Zimmer stem implantation (conical tapered stem) using the 3D CT based software for surgical pre-operative planning
|
In every hip (with appropriate CT scan), 3 different stem designs will be positioned using a 3D Ct based software for surgical pre-operative planning.
|
|
Aptafix stem
Aptafix Ortho stem implantation (anatomical stem) using the 3D CT based software for surgical pre-operative planning
|
In every hip (with appropriate CT scan), 3 different stem designs will be positioned using a 3D Ct based software for surgical pre-operative planning.
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Correct Reconstruction CLS
Časové okno: Day 0
|
Percentage of hips correctly reconstructed using CLS stem: the correctly reconstructed hip should have combined anteversion between 25° and 50°, global offset not inferior to 12% of the native offset, leg lengthening not superior to 3 cm, sagittal and coronal tilt not superior to +/-5°, canal filling not inferior to 80% (all the 5 parameters should be present at the same time).
Minimum-maximum values (as percentage %): 0-100.
100 is the best result, 0 the worst
|
Day 0
|
|
Correct Reconstruction Wagner Cone
Časové okno: Day 0
|
Percentage of hips correctly reconstructed using CLS stem: the correctly reconstructed hip should have combined anteversion between 25° and 50°, global offset not inferior to 12% of the native offset, leg lengthening not superior to 3 cm, sagittal and coronal tilt not superior to +/-5°, canal filling not inferior to 80% (all the 5 parameters should be present at the same time).
Minimum-maximum values (as percentage %): 0-100.
100 is the best result, 0 the worst
|
Day 0
|
|
Correct Reconstruction Aptafix
Časové okno: Day 0
|
Percentage of hips correctly reconstructed using CLS stem: the correctly reconstructed hip should have combined anteversion between 25° and 50°, global offset not inferior to 12% of the native offset, leg lengthening not superior to 3 cm, sagittal and coronal tilt not superior to +/-5°, canal filling not inferior to 80% (all the 5 parameters should be present at the same time).
Minimum-maximum values (as percentage %): 0-100.
100 is the best result, 0 the worst
|
Day 0
|
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Combined Anteversion CLS
Časové okno: Day 0
|
Percentage of hips with adequate combined anteversion according to Dorr (25-50°) and Widmer (<37°) using CLS stems.
Minimum-maximum values (as percentage %): 0-100.
100 is the best result, 0 is the worst
|
Day 0
|
|
Combined Anteversion Wagner Cone
Časové okno: Day 0
|
Percentage of hips with adequate combined anteversion according to Dorr (25-50°) and Widmer (<37°) using CLS stems.
Minimum-maximum values (as percentage %): 0-100.
100 is the best result, 0 is the worst
|
Day 0
|
|
Combined Anteversion Aptafix
Časové okno: Day 0
|
Percentage of hips with adequate combined anteversion according to Dorr (25-50°) and Widmer (<37°) using CLS stems.
Minimum-maximum values (as percentage %): 0-100.
100 is the best result, 0 is the worst
|
Day 0
|
|
Offset CLS
Časové okno: Day 0
|
Percentage of hips with acetabular+femoral offset not inferior to 12% of the native value using CLS stems.
Minimum-maximum values (as percentage %): 0-100.
100 is the best result, 0 is the worst
|
Day 0
|
|
Offset Wagner Cone
Časové okno: Day 0
|
Percentage of hips with acetabular+femoral offset not inferior to 12% of the native value using CLS stems.
Minimum-maximum values (as percentage %): 0-100.
100 is the best result, 0 is the worst
|
Day 0
|
|
Offset Aptafix
Časové okno: Day 0
|
Percentage of hips with acetabular+femoral offset not inferior to 12% of the native value using CLS stems.
Minimum-maximum values (as percentage %): 0-100.
100 is the best result, 0 is the worst
|
Day 0
|
|
Leg Lengthening CLS
Časové okno: Day 0
|
Percentage of hips with leg lengthening not superior to 3 cm using CLS stems.
Minimum-maximum values (as percentages %): 0-100.
100 is the best result, 0 is the worst
|
Day 0
|
|
Leg Lengthening Wagner Cone
Časové okno: Day 0
|
Percentage of hips with leg lengthening not superior to 3 cm using CLS stems.
Minimum-maximum values (as percentages %): 0-100.
100 is the best result, 0 is the worst
|
Day 0
|
|
Leg Lengthening Aptafix
Časové okno: Day 0
|
Percentage of hips with leg lengthening not superior to 3 cm using CLS stems.
Minimum-maximum values (as percentages %): 0-100.
100 is the best result, 0 is the worst
|
Day 0
|
Spolupracovníci a vyšetřovatelé
Sponzor
Vyšetřovatelé
- Ředitel studie: Francesco Traina, Professor, IRCCS Istituto Ortopedico Rizzoli
Publikace a užitečné odkazy
Obecné publikace
- Taniguchi N, Jinno T, Koga D, Hagino T, Okawa A, Haro H. Cementless Hip Stem Anteversion in the Dysplastic Hip: A Comparison of Tapered Wedge vs Metaphyseal Filling. J Arthroplasty. 2017 May;32(5):1547-1552. doi: 10.1016/j.arth.2016.12.020. Epub 2016 Dec 22.
- Argenson JN, Ryembault E, Flecher X, Brassart N, Parratte S, Aubaniac JM. Three-dimensional anatomy of the hip in osteoarthritis after developmental dysplasia. J Bone Joint Surg Br. 2005 Sep;87(9):1192-6. doi: 10.1302/0301-620X.87B9.15928.
- Sugano N, Takao M, Sakai T, Nishii T, Miki H. Does CT-based navigation improve the long-term survival in ceramic-on-ceramic THA? Clin Orthop Relat Res. 2012 Nov;470(11):3054-9. doi: 10.1007/s11999-012-2378-4.
- Castagnini F, Valente G, Crimi G, Taddei F, Bordini B, Stea S, Toni A. Component positioning and ceramic damage in cementless ceramic-on-ceramic total hip arthroplasty. J Orthop Sci. 2019 Jul;24(4):643-651. doi: 10.1016/j.jos.2018.12.011. Epub 2019 Jan 4.
Užitečné odkazy
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Primární dokončení (Aktuální)
Dokončení studie (Aktuální)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
Další identifikační čísla studie
- 29/2021/Oss/IOR
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .
Klinické studie na Dysplazie; Boky
-
University of Central FloridaNábor
-
Ziv Medical CenterDokončenoRozdíl v délce končetiny | Total Hip
-
Meir Medical CenterNábor
-
OrthoCarolina Research Institute, Inc.Presbyterian Pathology GroupUkončeno
-
Istituto Ortopedico RizzoliDokončenoHip Impingement Syndrome | Komplikace protetikyItálie
-
University of CologneDokončenoOperace páteře | Hip-artroplastika | Artroplastika kolenaNěmecko
-
Revalesio CorporationStaženo
-
Groupe Hospitalier Paris Saint JosephDokončenoZlomenina acetabula | Total HipFrancie
-
University of PittsburghDokončenoAcetabulární labrální slza | Hip Impingement SyndromeSpojené státy
-
University of AarhusAarhus University HospitalDokončeno
Klinické studie na Hip stem
-
SURGE TherapeuticsNáborRakovina prostatySpojené státy, Austrálie
-
SURGE TherapeuticsNáborNeinvazivní rakovina močového měchýřeSpojené státy
-
Iconacy Orthopedic Implants, LLC.StaženoDegenerativní onemocnění kloubů
-
Iconacy Orthopedic Implants, LLC.NeznámýDegenerativní onemocnění kloubůSpojené státy
-
Northeastern UniversityOregon Health and Science University; University of California, RiversideNábor
-
University of AarhusAarhus University Hospital; Zimmer BiometDokončenoOsteonekróza | Zlomenina krčku stehenní kosti | Selhání implantátuDánsko
-
AO Clinical Investigation and Publishing DocumentationUkončenoZlomeniny stehenní kosti | Zlomeniny kyčle | Osteoporóza | Hustota kostíNěmecko, Rakousko, Švýcarsko, Holandsko
-
Spokane Joint Replacement CenterDokončenoOsteoartróza, kyčleSpojené státy
-
Zimmer BiometDokončenoOsteoartróza | Revmatoidní artritida | Avaskulární nekróza | Selhání protézyŠvýcarsko, Německo, Itálie, Spojené království