- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT07724262
Evaluation of the Argos System to Estimate Cardiac Output
Evaluation of the Argos System to Estimate Cardiac Output in Critically Ill Patients
The goal of this observational study is to evaluate the reliability of the Argos system to track changes in cardiac output in critically ill patients. The main question it aims to answer is:
Does cardiac output changes induced by fluid administration or changes in norepinephrine dosage can be tracked by the Argos system, compared to transpulmonary thermodilution device.
연구 개요
상세 설명
In patients with acute circulatory failure, hemodynamic monitoring including cardiac index (CI) assessment is recommended for most severe patients. Transpulmonary thermodilution (TPTD) is one of the methods that are recommended for this purpose, in particular because it is considered as reliable in this type of patients. The PiCCO2 system (Pulsion Medical Systems, Getinge, Feldkirchen, Germany) relies on TPTD method and associate two methods to measure CI. On the one hand, TPTD is considered as one of the gold standards for CI evaluation (CITPTD). On the other hand, pulse contour analysis calculates stroke volume from the waveform of the systolic part of the arterial pressure curve (CIpwa). The way this estimation is performed and it is regularly re-evaluated differs among the devices that are available on the market. This estimation of CIpwa is calibrated when TPTD is performed. Thus, it allows a real-time pulse contour derived CI assessment, which is very precise. However, TPTD system are considered invasive, expensive and are not available in all settings.
The Argos monitor (Retia Medical, Valhalla, USA) uses the so-called multi-beat analysis (MBA) to estimate CI after analyzing the arterial pressure waveform over periods of multiple heartbeats (up to 20) and scaling CI estimations to biometric data. The algorithm estimates the theoretical central arterial blood pressure waveform using MBA, minimizing and avoiding the cofounding effect of the wave reflection phenomena. Based on this central arterial blood pressure waveform and biometric patient data, the system estimates cardiac output. The Argos monitor has a second advantage. It simply connects to the analogue output of the blood pressure signal from a compatible multi-parameter monitor and needs no additional specific pressure sensor. During cardiac surgery, the Argos monitor showed reasonable agreement and trending ability compared to the pulmonary artery catheter. However, in patients after cardiac surgery, including those with low cardiac output and arrhythmia, CI estimated by the device was not interchangeable with the continuous thermodilution method via a PAC.
The primary objective of the study is to evaluate the reliability of the Argos system to track changes of CI induced by changes in norepinephrine or fluid administration, compared to CITPTD in critically ill patients.
연구 유형
등록 (추정된)
연락처 및 위치
연구 연락처
- 이름: Christopher Lai, MD, PhD
- 전화번호: 12633816521
- 이메일: christopher.lai@aphp.fr
연구 장소
-
-
-
Le Kremlin-Bicêtre, 프랑스
- 모병
- Bicetre Hospital
-
연락하다:
- Christopher Lai
- 전화번호: 2633816521
- 이메일: christopher.lai@aphp.fr
-
-
참여기준
자격 기준
공부할 수 있는 나이
- 성인
- 고령자
건강한 자원 봉사자를 받아들입니다
샘플링 방법
연구 인구
Patients with shock defined by one sign of hypoperfusion:
- systolic arterial pressure <90mmHg
- mean arterial pressure <65mmHg
- prolonged capillary refill time >3 sec
- mottling score > 2
- urine output < 0.1 mL/kg/h
설명
Inclusion Criteria:
- Age ≥18 years old
- Hospitalisation in intensive care
- Haemodynamic monitoring with transpulmonary thermodilution already in place
Hemodynamic intervention deemed necessary by the clinician in charge of the patient
- Administration of a fluid bolus
- Change in norepinephrine dosage or performance of a vasopressor test
Exclusion Criteria:
- Pregnancy
- Other therapeutic modification during volume expansion or the vasopressor test
- Refusal to participate by relatives of the patient or the patient himself or herself
- Non availability of investigators
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
코호트 및 개입
그룹/코호트 |
개입 / 치료 |
|---|---|
|
patients with shock
Patients with shock defined by one sign of hypoperfusion:
|
Giving a fluid bolus of 500mL of normal saline (NaCl 0.9%)
brief, transient increase in norepinephrine to achieve a 15mmHg increase in mean arterial pressure and evaluates if tissue perfusion improves
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
기간 |
|---|---|
|
To compare the changes in cardiac output provided by the Argos system induced by changes in norepinephrine or fluid bolus, compared to cardiac output provided by the transpulmonary thermodilution device in critically ill patients.
기간: 1 hour (before and after intervention)
|
1 hour (before and after intervention)
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Accuracy of the Argos system
기간: 1 hour (before and after intervention)
|
To evaluate the accuracy of the Argos system to measure absolute values of cardiac output compared to transpulmonary thermodilution
|
1 hour (before and after intervention)
|
|
Precision of the Argos system
기간: 1 hour (before and after intervention)
|
To evaluate the precision and least significant change of cardiac output provided by the Argos system
|
1 hour (before and after intervention)
|
공동 작업자 및 조사자
스폰서
연구 기록 날짜
연구 주요 날짜
연구 시작 (실제)
기본 완료 (추정된)
연구 완료 (추정된)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (실제)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
추가 관련 MeSH 약관
기타 연구 ID 번호
- Argos study
- CE-SRLF 24-100 (기타 식별자: SRLF)
개별 참가자 데이터(IPD) 계획
개별 참가자 데이터(IPD)를 공유할 계획입니까?
약물 및 장치 정보, 연구 문서
미국 FDA 규제 의약품 연구
미국 FDA 규제 기기 제품 연구
미국에서 제조되어 미국에서 수출되는 제품
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .