Evaluation of the Argos System to Estimate Cardiac Output
Evaluation of the Argos System to Estimate Cardiac Output in Critically Ill Patients
The goal of this observational study is to evaluate the reliability of the Argos system to track changes in cardiac output in critically ill patients. The main question it aims to answer is:
Does cardiac output changes induced by fluid administration or changes in norepinephrine dosage can be tracked by the Argos system, compared to transpulmonary thermodilution device.
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Gedetailleerde beschrijving
In patients with acute circulatory failure, hemodynamic monitoring including cardiac index (CI) assessment is recommended for most severe patients. Transpulmonary thermodilution (TPTD) is one of the methods that are recommended for this purpose, in particular because it is considered as reliable in this type of patients. The PiCCO2 system (Pulsion Medical Systems, Getinge, Feldkirchen, Germany) relies on TPTD method and associate two methods to measure CI. On the one hand, TPTD is considered as one of the gold standards for CI evaluation (CITPTD). On the other hand, pulse contour analysis calculates stroke volume from the waveform of the systolic part of the arterial pressure curve (CIpwa). The way this estimation is performed and it is regularly re-evaluated differs among the devices that are available on the market. This estimation of CIpwa is calibrated when TPTD is performed. Thus, it allows a real-time pulse contour derived CI assessment, which is very precise. However, TPTD system are considered invasive, expensive and are not available in all settings.
The Argos monitor (Retia Medical, Valhalla, USA) uses the so-called multi-beat analysis (MBA) to estimate CI after analyzing the arterial pressure waveform over periods of multiple heartbeats (up to 20) and scaling CI estimations to biometric data. The algorithm estimates the theoretical central arterial blood pressure waveform using MBA, minimizing and avoiding the cofounding effect of the wave reflection phenomena. Based on this central arterial blood pressure waveform and biometric patient data, the system estimates cardiac output. The Argos monitor has a second advantage. It simply connects to the analogue output of the blood pressure signal from a compatible multi-parameter monitor and needs no additional specific pressure sensor. During cardiac surgery, the Argos monitor showed reasonable agreement and trending ability compared to the pulmonary artery catheter. However, in patients after cardiac surgery, including those with low cardiac output and arrhythmia, CI estimated by the device was not interchangeable with the continuous thermodilution method via a PAC.
The primary objective of the study is to evaluate the reliability of the Argos system to track changes of CI induced by changes in norepinephrine or fluid administration, compared to CITPTD in critically ill patients.
Studietype
Inschrijving (Geschat)
Contacten en locaties
Studiecontact
- Naam: Christopher Lai, MD, PhD
- Telefoonnummer: 12633816521
- E-mail: christopher.lai@aphp.fr
Studie Locaties
-
-
-
Le Kremlin-Bicêtre, Frankrijk
- Werving
- Bicetre Hospital
-
Contact:
- Christopher Lai
- Telefoonnummer: 2633816521
- E-mail: christopher.lai@aphp.fr
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Volwassen
- Oudere volwassene
Accepteert gezonde vrijwilligers
Bemonsteringsmethode
Studie Bevolking
Patients with shock defined by one sign of hypoperfusion:
- systolic arterial pressure <90mmHg
- mean arterial pressure <65mmHg
- prolonged capillary refill time >3 sec
- mottling score > 2
- urine output < 0.1 mL/kg/h
Beschrijving
Inclusion Criteria:
- Age ≥18 years old
- Hospitalisation in intensive care
- Haemodynamic monitoring with transpulmonary thermodilution already in place
Hemodynamic intervention deemed necessary by the clinician in charge of the patient
- Administration of a fluid bolus
- Change in norepinephrine dosage or performance of a vasopressor test
Exclusion Criteria:
- Pregnancy
- Other therapeutic modification during volume expansion or the vasopressor test
- Refusal to participate by relatives of the patient or the patient himself or herself
- Non availability of investigators
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
Cohorten en interventies
Groep / Cohort |
Interventie / Behandeling |
|---|---|
|
patients with shock
Patients with shock defined by one sign of hypoperfusion:
|
Giving a fluid bolus of 500mL of normal saline (NaCl 0.9%)
brief, transient increase in norepinephrine to achieve a 15mmHg increase in mean arterial pressure and evaluates if tissue perfusion improves
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Tijdsspanne |
|---|---|
|
To compare the changes in cardiac output provided by the Argos system induced by changes in norepinephrine or fluid bolus, compared to cardiac output provided by the transpulmonary thermodilution device in critically ill patients.
Tijdsspanne: 1 hour (before and after intervention)
|
1 hour (before and after intervention)
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Accuracy of the Argos system
Tijdsspanne: 1 hour (before and after intervention)
|
To evaluate the accuracy of the Argos system to measure absolute values of cardiac output compared to transpulmonary thermodilution
|
1 hour (before and after intervention)
|
|
Precision of the Argos system
Tijdsspanne: 1 hour (before and after intervention)
|
To evaluate the precision and least significant change of cardiac output provided by the Argos system
|
1 hour (before and after intervention)
|
Medewerkers en onderzoekers
Sponsor
Studie record data
Bestudeer belangrijke data
Studie start (Werkelijk)
Primaire voltooiing (Geschat)
Studie voltooiing (Geschat)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
- Pathologische processen
- Pathologische aandoeningen, tekenen en symptomen
- Schok
- Organische chemicaliën
- Koolwaterstoffen
- Koolwaterstoffen, cyclisch
- Koolwaterstoffen, aromatisch
- Amines
- Catechols
- Fenolen
- Benzeenderivaten
- Alcohol
- Aminoalcoholen
- Ethanolamines
- Biogene monoamine
- Biogene amines
- Catecholamines
- Noradrenaline
Andere studie-ID-nummers
- Argos study
- CE-SRLF 24-100 (Andere identificatie: SRLF)
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
product vervaardigd in en geëxporteerd uit de V.S.
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .