- ICH GCP
- Register voor klinische proeven in de VS.
- Klinische proef NCT01229020
Distribution of Regional Lung Function by Vibration Response Imaging
26 oktober 2010 bijgewerkt door: Deep Breeze
Distribution of Regional Lung Function, as Determined by the Vibration Response Image Generated by the VRI-2000 System as Compared With Standard Radio-nuclear Method
Assessment of regional contribution of different areas of the lung to its integrated function is often required, such as prior to lung resection in the presence of tumor or emphysema.
This assessment is derived from the proportion of zonal radionuclear perfusion or ventilation.
The investigators hypothesized that lung VRI may provide an alternative approach to assess regional lung function.
Studie Overzicht
Toestand
Voltooid
Interventie / Behandeling
Gedetailleerde beschrijving
Patients diagnosed with moderate-to-severe COPD by lung function studies and clinical evaluation presented in stable clinical condition and were evaluated by lung sound recordings and quantitative V/Q lung scintigraphy.
Regional signals (percentage of lung sounds) for left and right lungs were compared with the corresponding regional count percentages of each radionuclide scan, by V/Q scan regions of interest.
Studietype
Observationeel
Inschrijving (Werkelijk)
25
Contacten en locaties
In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.
Studie Locaties
-
-
-
Ramat-Gan, Israël, 52621
- Chaim Sheba Medical Center at Tel Hashomer
-
-
Deelname Criteria
Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
18 jaar tot 85 jaar (Volwassen, Oudere volwassene)
Accepteert gezonde vrijwilligers
Nee
Geslachten die in aanmerking komen voor studie
Allemaal
Bemonsteringsmethode
Kanssteekproef
Studie Bevolking
Males and females who were diagnosed with moderate-to-severe COPD by lung function studies and clinical evaluation
Beschrijving
Inclusion Criteria:
- Patient is able to read and understand the Informed Consent Form and he/she will provide written Informed Consent.
- Male or female in the age range of 18-85 years.
- The patient will undergo V/Q scan (up to ONE WEEK from the VRI recording)
- The patient presented for evaluation of COPD.
- Body Mass Index >21.
Exclusion Criteria:
- Unstable clinical status such as fever, acute shortness of breath, cough, hemoptysis, cheat pain, or acute chest illness.
- Chest wall deformation;
- Spine deformation (including severe scoliosis);
- Hirsutism;
- Potentially contagious skin lesion on the back;
- Skin lesion that would interfere with sensor placement;
Any additional chronic lung disease of any findings such as past tuberculosis, visualized on CXR.
8. Previous resection lung surgery and history of lung tumor; 9. Cardiac pacemaker or implantable defibrillator
Studie plan
Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.
Hoe is de studie opgezet?
Ontwerpdetails
- Observatiemodellen: Cohort
- Tijdsperspectieven: Prospectief
Cohorten en interventies
Groep / Cohort |
Interventie / Behandeling |
|---|---|
|
COPD patients
Patients diagnosed with COPD, by the pulmonologist at the institute,who are referred to undergo ventilation/perfusion scans.
|
Observational study - no intervention.
Patients underwent VRI recordings and routine V/Q scan.
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
|---|---|
|
Comparison of regional lung vibration energy with regional lung function
|
To map regional lung vibration energy in patients with emphysema by using the lung image generated by the VRI system and compare findings to distibution of perfusion and ventilation in standard V/Q scans
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
|---|---|
|
Correlation of vibration lung sound energy with regional lung functions by V/Q scan
|
Evaluate if the regional vibration energy is correlated with regional lung functions, as assessed by V/Q scan
|
Medewerkers en onderzoekers
Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.
Sponsor
Onderzoekers
- Hoofdonderzoeker: Issahar Ben-Dov, MD, Chaim Sheba Medical Center
Publicaties en nuttige links
De persoon die verantwoordelijk is voor het invoeren van informatie over het onderzoek stelt deze publicaties vrijwillig ter beschikking. Dit kan gaan over alles wat met het onderzoek te maken heeft.
Algemene publicaties
- Celli BR, MacNee W; ATS/ERS Task Force. Standards for the diagnosis and treatment of patients with COPD: a summary of the ATS/ERS position paper. Eur Respir J. 2004 Jun;23(6):932-46. doi: 10.1183/09031936.04.00014304. No abstract available. Erratum In: Eur Respir J. 2006 Jan;27(1):242.
- Demir T, Ikitimur H, Akpinar Tekgunduz S, Mutlu B, Yildirim N, Akman C, Ozmen O, Kanmaz B. The relationship between pulmonary function tests, thorax HRCT, and quantitative ventilation-perfusion scintigraphy in chronic obstructive pulmonary disease. Tuberk Toraks. 2005;53(4):347-53.
- Kramer MR, Raviv Y, Hardoff R, Shteinmatz A, Amital A, Shitrit D. Regional breath sound distribution analysis in single-lung transplant recipients. J Heart Lung Transplant. 2007 Nov;26(11):1149-54. doi: 10.1016/j.healun.2007.07.039.
- Ikonen T, Harjula AL, Kinnula V, Savola J, Sovijarvi AR. Selective assessment of single-lung graft function with 133Xe radiospirometry in acute rejection and infection. Chest. 1996 Apr;109(4):879-84. doi: 10.1378/chest.109.4.879.
- Guntupalli KK, Reddy RM, Loutfi RH, Alapat PM, Bandi VD, Hanania NA. Evaluation of obstructive lung disease with vibration response imaging. J Asthma. 2008 Dec;45(10):923-30. doi: 10.1080/02770900802395496.
Studie record data
Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.
Bestudeer belangrijke data
Studie start
1 februari 2004
Primaire voltooiing (Werkelijk)
1 januari 2006
Studie voltooiing (Werkelijk)
1 januari 2006
Studieregistratiedata
Eerst ingediend
26 oktober 2010
Eerst ingediend dat voldeed aan de QC-criteria
26 oktober 2010
Eerst geplaatst (Schatting)
27 oktober 2010
Updates van studierecords
Laatste update geplaatst (Schatting)
27 oktober 2010
Laatste update ingediend die voldeed aan QC-criteria
26 oktober 2010
Laatst geverifieerd
1 oktober 2010
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- DB010
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .