Could the Cerebral Oximetry be a Good Technology to Measure Placental Oxygenation?
Could the Cerebral Oximetry (NIRS) be a Good Technology to Measure Placental Oxygenation in Pregnant Woman?
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Gedetailleerde beschrijving
There is general agreement among experts to recommend the use of phenylephrine as first line therapy for the treatment of arterial hypotension induced by spinal anaesthesia during caesarean delivery. In some studies, there are trends toward a lower PaO2 values in the umbilical cord venous blood when the mother receive this vasopressor. These findings may be a result of the vasoconstrictor effect of phenylephrine on utero-placental vessels, and a subsequent increased oxygen extraction by the fetus. The possibility to extract more oxygen would provide a certain "safety margin" in the event of compromised utero-placental blood flow during normal pregnancy. However, this "safety margin" should not be taken for granted in cases where signs of fetal distress are present, and this situation might influence the choice of vasopressors.
It is well establish on a physiological basis that during labour, utero-placental blood flow is lower during the contractions. This lower blood flow could result in a lower saturation value measured by the cerebral oximeter.
Twenty patients in labour will be included in this study. Patients will be recruited in obstetric clinic during pregnancy. Based on the second trimester ultrasound, patients with anterior placenta will be included.
During labour, once a functional epidural is in place, an Invos oximeter will be install. Two sensors will be applied on the abdomen (one above the placenta and the other above the myometrium at a place without placenta). Two sensors will also be applied on the extremities (forearm and leg).Saturation values and timing of the contractions will be recorded for sixty minutes. Half of the recording will be done with an oxygen mask. Vitals signs will also be registered every five minutes.
Studietype
Inschrijving (Werkelijk)
Contacten en locaties
Studie Locaties
-
-
Quebec
-
Montreal, Quebec, Canada, H1T 2M4
- Maisonneuve Rosemont Hospital
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Bemonsteringsmethode
Studie Bevolking
Beschrijving
Inclusion Criteria:
- healthy pregnant woman (ASA I or II)
- Term gestation ( > 37 weeks)
- Normal pregnancy
- vaginal delivery
- obstetrical epidural in place
- anterior placenta
Exclusion Criteria:
- patient refusal
- Any contraindication to neuraxial anesthesia
- cesarean section
- multiple gestation
- placentation abnormalities
- anormal placental perfusion
- Placental Abruption
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
Cohorten en interventies
Groep / Cohort |
Interventie / Behandeling |
|---|---|
|
anterior placenta
Cerebral oximetry device used to obtain: Saturation value of the placenta probe with no oxygen, saturation value of the placenta probe with oxygen, saturation value of the myometrium probe with no oxygen saturation value of the myometrium probe with oxygen saturation value of the forearm probe with no oxygen, saturation value of the forearm probe with oxygen saturation value of the leg probe with no oxygen saturation value of the leg probe with oxygen Timing between the contractions measure by cardiotocography |
tissue saturation measurement in pregnant women
Andere namen:
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Difference between Δp and Δm
Tijdsspanne: 60 minutes
|
Δp = Difference between the mean value area under the curve for the placenta and arm = (Ap- Af) Δm= Difference between the mean value area under the curve for the myometrium and arm = (Am- Af)
|
60 minutes
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Difference of the area under the curve of saturation with and without oxygen
Tijdsspanne: 60 minutes
|
Ap with Oxygen - Ap without oxygen; Am with oxygen - Am without oxygen
|
60 minutes
|
Medewerkers en onderzoekers
Sponsor
Medewerkers
Onderzoekers
- Hoofdonderzoeker: Christian Loubert, MD, FRCPC, Maisonneuve-Rosemont Hospital
Studie record data
Bestudeer belangrijke data
Studie start
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Updates van studierecords
Laatste update geplaatst (Schatting)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Trefwoorden
Andere studie-ID-nummers
- LoubertHMR2013/04
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .