- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT01834599
Could the Cerebral Oximetry be a Good Technology to Measure Placental Oxygenation?
Could the Cerebral Oximetry (NIRS) be a Good Technology to Measure Placental Oxygenation in Pregnant Woman?
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
There is general agreement among experts to recommend the use of phenylephrine as first line therapy for the treatment of arterial hypotension induced by spinal anaesthesia during caesarean delivery. In some studies, there are trends toward a lower PaO2 values in the umbilical cord venous blood when the mother receive this vasopressor. These findings may be a result of the vasoconstrictor effect of phenylephrine on utero-placental vessels, and a subsequent increased oxygen extraction by the fetus. The possibility to extract more oxygen would provide a certain "safety margin" in the event of compromised utero-placental blood flow during normal pregnancy. However, this "safety margin" should not be taken for granted in cases where signs of fetal distress are present, and this situation might influence the choice of vasopressors.
It is well establish on a physiological basis that during labour, utero-placental blood flow is lower during the contractions. This lower blood flow could result in a lower saturation value measured by the cerebral oximeter.
Twenty patients in labour will be included in this study. Patients will be recruited in obstetric clinic during pregnancy. Based on the second trimester ultrasound, patients with anterior placenta will be included.
During labour, once a functional epidural is in place, an Invos oximeter will be install. Two sensors will be applied on the abdomen (one above the placenta and the other above the myometrium at a place without placenta). Two sensors will also be applied on the extremities (forearm and leg).Saturation values and timing of the contractions will be recorded for sixty minutes. Half of the recording will be done with an oxygen mask. Vitals signs will also be registered every five minutes.
Tipo di studio
Iscrizione (Effettivo)
Contatti e Sedi
Luoghi di studio
-
-
Quebec
-
Montreal, Quebec, Canada, H1T 2M4
- Maisonneuve Rosemont Hospital
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Metodo di campionamento
Popolazione di studio
Descrizione
Inclusion Criteria:
- healthy pregnant woman (ASA I or II)
- Term gestation ( > 37 weeks)
- Normal pregnancy
- vaginal delivery
- obstetrical epidural in place
- anterior placenta
Exclusion Criteria:
- patient refusal
- Any contraindication to neuraxial anesthesia
- cesarean section
- multiple gestation
- placentation abnormalities
- anormal placental perfusion
- Placental Abruption
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
Coorti e interventi
Gruppo / Coorte |
Intervento / Trattamento |
|---|---|
|
anterior placenta
Cerebral oximetry device used to obtain: Saturation value of the placenta probe with no oxygen, saturation value of the placenta probe with oxygen, saturation value of the myometrium probe with no oxygen saturation value of the myometrium probe with oxygen saturation value of the forearm probe with no oxygen, saturation value of the forearm probe with oxygen saturation value of the leg probe with no oxygen saturation value of the leg probe with oxygen Timing between the contractions measure by cardiotocography |
tissue saturation measurement in pregnant women
Altri nomi:
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Difference between Δp and Δm
Lasso di tempo: 60 minutes
|
Δp = Difference between the mean value area under the curve for the placenta and arm = (Ap- Af) Δm= Difference between the mean value area under the curve for the myometrium and arm = (Am- Af)
|
60 minutes
|
Misure di risultato secondarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Difference of the area under the curve of saturation with and without oxygen
Lasso di tempo: 60 minutes
|
Ap with Oxygen - Ap without oxygen; Am with oxygen - Am without oxygen
|
60 minutes
|
Collaboratori e investigatori
Sponsor
Collaboratori
Investigatori
- Investigatore principale: Christian Loubert, MD, FRCPC, Maisonneuve-Rosemont Hospital
Studiare le date dei record
Studia le date principali
Inizio studio
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Stima)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Altri numeri di identificazione dello studio
- LoubertHMR2013/04
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .
Prove cliniche su cerebral oximetry
-
China National Center for Cardiovascular DiseasesIscrizione su invitoIctus | Sostituzione della valvola aortica transcatetere (TAVR) | Stenosi aortica trattata con TAVICina
-
St. John's Research InstituteRigshospitalet, DenmarkNon ancora reclutamentoInsufficienza renale acuta | Morbilità neonataleIndia
-
Mayo ClinicNational Cancer Institute (NCI)Non ancora reclutamento
-
University of California, DavisCompletatoChirurgia | EmoglobinaStati Uniti
-
Assistance Publique - Hôpitaux de ParisURC-CIC Paris Descartes Necker CochinCompletatoOssigenazione extra corporea della membranaFrancia
-
Instituto Nacional de Cardiologia de LaranjeirasCompletatoDisfunzione cognitiva | Malattia cardiacaBrasile
-
Klinik Hirslanden, ZurichSconosciutoMisurazione transcutanea continua dell'emoglobina