- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT01834599
Could the Cerebral Oximetry be a Good Technology to Measure Placental Oxygenation?
Could the Cerebral Oximetry (NIRS) be a Good Technology to Measure Placental Oxygenation in Pregnant Woman?
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Descrição detalhada
There is general agreement among experts to recommend the use of phenylephrine as first line therapy for the treatment of arterial hypotension induced by spinal anaesthesia during caesarean delivery. In some studies, there are trends toward a lower PaO2 values in the umbilical cord venous blood when the mother receive this vasopressor. These findings may be a result of the vasoconstrictor effect of phenylephrine on utero-placental vessels, and a subsequent increased oxygen extraction by the fetus. The possibility to extract more oxygen would provide a certain "safety margin" in the event of compromised utero-placental blood flow during normal pregnancy. However, this "safety margin" should not be taken for granted in cases where signs of fetal distress are present, and this situation might influence the choice of vasopressors.
It is well establish on a physiological basis that during labour, utero-placental blood flow is lower during the contractions. This lower blood flow could result in a lower saturation value measured by the cerebral oximeter.
Twenty patients in labour will be included in this study. Patients will be recruited in obstetric clinic during pregnancy. Based on the second trimester ultrasound, patients with anterior placenta will be included.
During labour, once a functional epidural is in place, an Invos oximeter will be install. Two sensors will be applied on the abdomen (one above the placenta and the other above the myometrium at a place without placenta). Two sensors will also be applied on the extremities (forearm and leg).Saturation values and timing of the contractions will be recorded for sixty minutes. Half of the recording will be done with an oxygen mask. Vitals signs will also be registered every five minutes.
Tipo de estudo
Inscrição (Real)
Contactos e Locais
Locais de estudo
-
-
Quebec
-
Montreal, Quebec, Canadá, H1T 2M4
- Maisonneuve Rosemont Hospital
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
- healthy pregnant woman (ASA I or II)
- Term gestation ( > 37 weeks)
- Normal pregnancy
- vaginal delivery
- obstetrical epidural in place
- anterior placenta
Exclusion Criteria:
- patient refusal
- Any contraindication to neuraxial anesthesia
- cesarean section
- multiple gestation
- placentation abnormalities
- anormal placental perfusion
- Placental Abruption
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
Coortes e Intervenções
Grupo / Coorte |
Intervenção / Tratamento |
|---|---|
|
anterior placenta
Cerebral oximetry device used to obtain: Saturation value of the placenta probe with no oxygen, saturation value of the placenta probe with oxygen, saturation value of the myometrium probe with no oxygen saturation value of the myometrium probe with oxygen saturation value of the forearm probe with no oxygen, saturation value of the forearm probe with oxygen saturation value of the leg probe with no oxygen saturation value of the leg probe with oxygen Timing between the contractions measure by cardiotocography |
tissue saturation measurement in pregnant women
Outros nomes:
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Difference between Δp and Δm
Prazo: 60 minutes
|
Δp = Difference between the mean value area under the curve for the placenta and arm = (Ap- Af) Δm= Difference between the mean value area under the curve for the myometrium and arm = (Am- Af)
|
60 minutes
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Difference of the area under the curve of saturation with and without oxygen
Prazo: 60 minutes
|
Ap with Oxygen - Ap without oxygen; Am with oxygen - Am without oxygen
|
60 minutes
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Investigadores
- Investigador principal: Christian Loubert, MD, FRCPC, Maisonneuve-Rosemont Hospital
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Estimativa)
Atualizações de registro de estudo
Última Atualização Postada (Estimativa)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Outros números de identificação do estudo
- LoubertHMR2013/04
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .
Ensaios clínicos em cerebral oximetry
-
The University of Texas at DallasConcluídoCâncer de Mama FemininoEstados Unidos
-
Stanford UniversityConcluídoTranstorno de Déficit de Atenção e HiperatividadeEstados Unidos
-
University of MichiganConcluídoDerrameEstados Unidos
-
Nationwide Children's HospitalConcluído
-
University of FloridaBoston Scientific CorporationRecrutamentoDoença de Parkinson | Estimulação Cerebral ProfundaEstados Unidos
-
The Cleveland ClinicConcluídoAneurisma do Arco AórticoEstados Unidos
-
Abbott Medical DevicesRescindidoTranstorno Depressivo Maior | Depressão UnipolarEstados Unidos, Canadá, Reino Unido
-
University of California, San FranciscoNational Institute of Neurological Disorders and Stroke (NINDS)RecrutamentoDP - Doença de ParkinsonEstados Unidos
-
Zhiqi MaoRecrutamentoMal de Parkinson | Função executiva | Eletroencefalograma | Espectroscopia Funcional de Infravermelho PróximoChina
-