Evaluating Air Leak Detection in Intubated Patients
A Study to Evaluate Air Leak Detection Above the Endotracheal Cuff in Intubated Patients Using the AnapnoGuard 100 System
This trial is designed to assess the effectiveness of the AnapnoGaurd 100 system relative to standard of care (SOC) Control, in the course of mechanical ventilation and intubation. The main effectiveness aspect of this trial is the AnapnoGaurd 100's ability to reduce leaks between the endotracheal tube and the trachea walls as a result of the cuff pressure management. Since the primary outcome can't be measured by any method other than the investigational device, the study groups will be treated as follows:
- The Treatment group in this study will be treated with the fully functional AnapnoGaurd 100 device (per its intended use),
- The Control group will be treated with the AnapnoGuard device, where the cuff control will be disabled (off) and the cuff management will be done according to SOC.
Effectiveness will be measured by the duration and level of carbon dioxide (CO2) leakage around the endotracheal tube (ETT) cuff, from the lungs to the subglottic space and safety will be measured by adverse events (AEs).
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Studietype
Inschrijving (Werkelijk)
Fase
- Niet toepasbaar
Contacten en locaties
Studie Locaties
-
-
-
Bnei Brak, Israël
- Mayanei Hayeshua Medical Center, General ICU
-
Haifa, Israël
- Rambam Medical Center, Cardiac Surgery Department
-
Haifa, Israël
- Rambam Medical Center, Neurosurgery Department
-
Holon, Israël
- Wolfson Medical Center, General ICU
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Beschrijving
Inclusion Criteria:
- Age above 18 (men and women);
- Subject is expected to receive mechanical ventilation for more than 12 hours;
- Connection of the ETT to the AnapnoGuard system within 12 hours from intubation initiation;
- Subject or subject's legally acceptable representative signed the Informed Consent Form
Exclusion Criteria:
1. Subjects with facial, oropharyngeal or neck trauma 2. BMI>40 3. Pregnant women 4. Patient ventilated in prone position 5. Difficult intubation (defined as more than 3 intubation attempts)
-
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Preventie
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Enkel
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: Study group
Subjects in the study group will be connected to the AnapnoGuard 100 control unit operating in the normal clinical mode (automatic CO2 leak measurement above the cuff, cuff pressure control, evacuation of secretions and tracheal rinsing)
|
|
|
Actieve vergelijker: Control group
Subjects in the control group will be connected to the AnapnoGuard 100 control unit.
In the control group, the cuff pressure control of the AnapnoGuard 100 control unit will be disabled (OFF).
CO2 level above the cuff will be recorded.
Suction and rinsing function will operate after the system detects no CO2.
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
CO2 Leakage Above the ETT Cuff, Measured Over Time.
Tijdsspanne: Subjects will be followed for the duration of endotracheal intubation, an expected average of 4 days
|
Trial outcome measure represents patients' exposure to CO2 leakage standardized per hour. Specifically, each patients' area under the curve (AUC) of CO2 leakage (mmHg) is computed over the whole trial by multiplying leakage duration (X-axis; continuous time) by CO2 level (Y-axis; mmHg), divided by the patient's number of hours in the trial. Outcome measure is thus [CO2 mmHg*hour]/hour. CO2 leakage is the concentration of CO2 above the cuff as measured by the AG100 system every few minutes (in clinical mode). Time points which created the curve were every two adjacent time intervals having a valid CO2 reading. |
Subjects will be followed for the duration of endotracheal intubation, an expected average of 4 days
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Number of the Cuff Pressure Measurements Within the Safety Accepted Range (24 and 40cmH2O)
Tijdsspanne: Subjects will be followed for the duration of endotracheal intubation, an expected average of 4 days
|
mean number of cuff pressure measurements within the safety accepted range of 24 and 40 cmH2O, normalized using the total number of valid cuff pressure measurements.
|
Subjects will be followed for the duration of endotracheal intubation, an expected average of 4 days
|
Medewerkers en onderzoekers
Sponsor
Onderzoekers
- Studie directeur: Shai Efrati, MD, Hospitech Respiration
- Hoofdonderzoeker: Gil Bolotin, MD
Studie record data
Bestudeer belangrijke data
Studie start
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Andere studie-ID-nummers
- HST-AG-07
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .