Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

Temperature and Healing in Treatment of Gingival Enlargement

10 juli 2019 bijgewerkt door: mehmet murat taskan, Tokat Gaziosmanpasa University

Evaluation of Temperature and Healing in Treatment of Gingival Enlargement Using Different Gingivectomy Techniques

Aim: Gingival enlargement is a common clinical condition which requires surgical approaches to alleviating these enlargement areas. The aim of this study was to investigate epithelization, gingival temperature, inflammation and pain levels in post-operative healing process in 4 different gingivectomy techniques including Er:YAG laser, Nd:YAG laser, electrosurgery and conventional gingivectomy in treatment of chronic inflammatory gingival enlargements.

Material and Method: A split-mouth designed study was conducted on 37 systemically healthy patients consisting of 19 females and 18 males, who had gingival enlargement areas on the left and right of maxillary and mandibular anterior regions. Gingival crevicular fluid (GCF) samples were collected, clinical periodontal parameters and gingival temperature levels were recorded at baseline and in the postoperative period. The gingival temperature was measured during surgical procedures. Gingival temperature and epithelization levels in 3rd, 7th, 10th and 15th days; GCF levels in 15th, 30th, and 90th days and pain levels in 2nd and 8th hours and between 1st-7th days of post-operative healing process were evaluated.

Studie Overzicht

Studietype

Ingrijpend

Inschrijving (Werkelijk)

30

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

      • Tokat, Kalkoen, 60100
        • Gaziosmanpasa University

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

18 jaar tot 40 jaar (Volwassen)

Accepteert gezonde vrijwilligers

Ja

Geslachten die in aanmerking komen voor studie

Allemaal

Beschrijving

Inclusion Criteria:

  • systemically healthy individuals
  • the existence of at least 20 functioning teeth, the existence of chronic inflammatory gingival enlargement in anterior quadrants.

Exclusion Criteria:

  • pregnancy/lactation
  • drug use, previous periodontal therapy within 6 months
  • previous antibiotic use within 6 months, smoking
  • the existence of attachment/bone loss. .

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Diagnostisch
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Parallelle opdracht
  • Masker: Enkel

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Ander: group 1;
Er:YAG laser
  1. Er: YAG laser (Fotana AT Fidelis III, Ljubljana, Slovenia) 200 mj, 10 Hz, 2 Watt and VLP (long pulse, 1000 μs); 1.3 mm diameter, 8 mm long cylindrical, a sapphire tip was used with air cooling and water irrigation.
  2. Nd: YAG laser (Fotana AT Fidelis III, Ljubljana, Slovenia) was applied at 4 watts, 50 Hz, 300 μm microfiber tip and SP (short pulse: 180 μs) settings.
  3. Electrosurgical (Servotome Classic System, High Frequency Surgical Equipment, Satelec, France).
  4. Conventional surgical method was applied with hand instruments and gingivectomy knives.
Ander: group 2
Nd:YAG laser
  1. Er: YAG laser (Fotana AT Fidelis III, Ljubljana, Slovenia) 200 mj, 10 Hz, 2 Watt and VLP (long pulse, 1000 μs); 1.3 mm diameter, 8 mm long cylindrical, a sapphire tip was used with air cooling and water irrigation.
  2. Nd: YAG laser (Fotana AT Fidelis III, Ljubljana, Slovenia) was applied at 4 watts, 50 Hz, 300 μm microfiber tip and SP (short pulse: 180 μs) settings.
  3. Electrosurgical (Servotome Classic System, High Frequency Surgical Equipment, Satelec, France).
  4. Conventional surgical method was applied with hand instruments and gingivectomy knives.
Ander: group 3
Electrosurgery
  1. Er: YAG laser (Fotana AT Fidelis III, Ljubljana, Slovenia) 200 mj, 10 Hz, 2 Watt and VLP (long pulse, 1000 μs); 1.3 mm diameter, 8 mm long cylindrical, a sapphire tip was used with air cooling and water irrigation.
  2. Nd: YAG laser (Fotana AT Fidelis III, Ljubljana, Slovenia) was applied at 4 watts, 50 Hz, 300 μm microfiber tip and SP (short pulse: 180 μs) settings.
  3. Electrosurgical (Servotome Classic System, High Frequency Surgical Equipment, Satelec, France).
  4. Conventional surgical method was applied with hand instruments and gingivectomy knives.

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Epithelization
Tijdsspanne: Epithelization was evaluated at postoperative 7th day
Wound surface epithelization in the healing process was evaluated with a staining solution (Mira-2-tone, GMBH & Co., Duisburg, Germany). (O. Ozcelik et al., 2008)
Epithelization was evaluated at postoperative 7th day

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Gingival temperature
Tijdsspanne: The gingival temperature was measured during surgical procedures
The temperature measurement during the process was performed by an infrared thermometer (Optris GMBH, Manuel LS, Berlin, Germany). The device had a measurement and recording range from -35 ° C to 900 ° C, optical resolution 75: 1, thermal resolution 0.1 ° C, waveband range 8-14, USB interface and graphical software program.
The gingival temperature was measured during surgical procedures

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

1 januari 2012

Primaire voltooiing (Werkelijk)

1 mei 2013

Studie voltooiing (Werkelijk)

1 december 2013

Studieregistratiedata

Eerst ingediend

8 juli 2019

Eerst ingediend dat voldeed aan de QC-criteria

10 juli 2019

Eerst geplaatst (Werkelijk)

11 juli 2019

Updates van studierecords

Laatste update geplaatst (Werkelijk)

11 juli 2019

Laatste update ingediend die voldeed aan QC-criteria

10 juli 2019

Laatst geverifieerd

1 juli 2019

Meer informatie

Termen gerelateerd aan deze studie

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren