Evaluation of Temperature and Healing in Treatment of Gingival Enlargement Using Different Gingivectomy Techniques

Aim: Gingival enlargement is a common clinical condition which requires surgical approaches to alleviating these enlargement areas. The aim of this study was to investigate epithelization, gingival temperature, inflammation and pain levels in post-operative healing process in 4 different gingivectomy techniques including Er:YAG laser, Nd:YAG laser, electrosurgery and conventional gingivectomy in treatment of chronic inflammatory gingival enlargements.

Material and Method: A split-mouth designed study was conducted on 37 systemically healthy patients consisting of 19 females and 18 males, who had gingival enlargement areas on the left and right of maxillary and mandibular anterior regions. Gingival crevicular fluid (GCF) samples were collected, clinical periodontal parameters and gingival temperature levels were recorded at baseline and in the postoperative period. The gingival temperature was measured during surgical procedures. Gingival temperature and epithelization levels in 3rd, 7th, 10th and 15th days; GCF levels in 15th, 30th, and 90th days and pain levels in 2nd and 8th hours and between 1st-7th days of post-operative healing process were evaluated.

Panoramica dello studio

Tipo di studio

Interventistico

Iscrizione (Effettivo)

30

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

      • Tokat, Tacchino, 60100
        • Gaziosmanpasa University

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 18 anni a 40 anni (Adulto)

Accetta volontari sani

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • systemically healthy individuals
  • the existence of at least 20 functioning teeth, the existence of chronic inflammatory gingival enlargement in anterior quadrants.

Exclusion Criteria:

  • pregnancy/lactation
  • drug use, previous periodontal therapy within 6 months
  • previous antibiotic use within 6 months, smoking
  • the existence of attachment/bone loss. .

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Diagnostico
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione parallela
  • Mascheramento: Separare

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Altro: group 1;
Er:YAG laser
  1. Er: YAG laser (Fotana AT Fidelis III, Ljubljana, Slovenia) 200 mj, 10 Hz, 2 Watt and VLP (long pulse, 1000 μs); 1.3 mm diameter, 8 mm long cylindrical, a sapphire tip was used with air cooling and water irrigation.
  2. Nd: YAG laser (Fotana AT Fidelis III, Ljubljana, Slovenia) was applied at 4 watts, 50 Hz, 300 μm microfiber tip and SP (short pulse: 180 μs) settings.
  3. Electrosurgical (Servotome Classic System, High Frequency Surgical Equipment, Satelec, France).
  4. Conventional surgical method was applied with hand instruments and gingivectomy knives.
Altro: group 2
Nd:YAG laser
  1. Er: YAG laser (Fotana AT Fidelis III, Ljubljana, Slovenia) 200 mj, 10 Hz, 2 Watt and VLP (long pulse, 1000 μs); 1.3 mm diameter, 8 mm long cylindrical, a sapphire tip was used with air cooling and water irrigation.
  2. Nd: YAG laser (Fotana AT Fidelis III, Ljubljana, Slovenia) was applied at 4 watts, 50 Hz, 300 μm microfiber tip and SP (short pulse: 180 μs) settings.
  3. Electrosurgical (Servotome Classic System, High Frequency Surgical Equipment, Satelec, France).
  4. Conventional surgical method was applied with hand instruments and gingivectomy knives.
Altro: group 3
Electrosurgery
  1. Er: YAG laser (Fotana AT Fidelis III, Ljubljana, Slovenia) 200 mj, 10 Hz, 2 Watt and VLP (long pulse, 1000 μs); 1.3 mm diameter, 8 mm long cylindrical, a sapphire tip was used with air cooling and water irrigation.
  2. Nd: YAG laser (Fotana AT Fidelis III, Ljubljana, Slovenia) was applied at 4 watts, 50 Hz, 300 μm microfiber tip and SP (short pulse: 180 μs) settings.
  3. Electrosurgical (Servotome Classic System, High Frequency Surgical Equipment, Satelec, France).
  4. Conventional surgical method was applied with hand instruments and gingivectomy knives.

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Epithelization
Lasso di tempo: Epithelization was evaluated at postoperative 7th day
Wound surface epithelization in the healing process was evaluated with a staining solution (Mira-2-tone, GMBH & Co., Duisburg, Germany). (O. Ozcelik et al., 2008)
Epithelization was evaluated at postoperative 7th day

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Gingival temperature
Lasso di tempo: The gingival temperature was measured during surgical procedures
The temperature measurement during the process was performed by an infrared thermometer (Optris GMBH, Manuel LS, Berlin, Germany). The device had a measurement and recording range from -35 ° C to 900 ° C, optical resolution 75: 1, thermal resolution 0.1 ° C, waveband range 8-14, USB interface and graphical software program.
The gingival temperature was measured during surgical procedures

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

1 gennaio 2012

Completamento primario (Effettivo)

1 maggio 2013

Completamento dello studio (Effettivo)

1 dicembre 2013

Date di iscrizione allo studio

Primo inviato

8 luglio 2019

Primo inviato che soddisfa i criteri di controllo qualità

10 luglio 2019

Primo Inserito (Effettivo)

11 luglio 2019

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

11 luglio 2019

Ultimo aggiornamento inviato che soddisfa i criteri QC

10 luglio 2019

Ultimo verificato

1 luglio 2019

Maggiori informazioni

Termini relativi a questo studio

Piano per i dati dei singoli partecipanti (IPD)

Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?

NO

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su Er:YAG LASER, Nd:YAG laser, elctrosurgery, conventional surgery

3
Sottoscrivi