Impact of Allometric Pacing Rate on Ventricular Diastolic Function and Cerebral Blood Flow in Hypertensive Patients With Sinus Node Dysfunction
The study is a prospective, randomized controlled study in hypertensive patients with a bradycardia indications for pacing therapy and a plan to receive dual-chamber pacemaker. Enrolled patients will be randomized 1:1 into the control group and the allometric-pace group. In the control group, the pacing lower rate will be set to the nominal 60 bpm post a dual-chamber pacemaker implantation as frequently used in clinical practice, while in the allometric-pace group, the pacing rate will be programmed at 75 bpm based on the estimation for Chinese population with a height of 165-170 cm (also called personalized lower rate) or based on the symptom-relief per clinical assessment by the study physicians. Each patient will undergo baseline assessments and 3-month follow-up visits. At the enrollment and office visits, each patient will undergo arterial blood pressure measurement, cardiac functional assessment and cerebral blood flow measurement. At the end of the study, the study physician will adjust pacing lower rate based on patients' conditions and clinical assessments. After the completion of the study, all patients will have regular device follow-up visit, usually 6-month interval or annually.
Each patient will receive the following major assessments: device performance and pacing percentages, ventricular diastolic function by doppler and echocardiography of LVEF, LVEDV, LVESV, stroke volume, cardiac output, arterial blood pressure measurements, cerebral blood flow by MRI or Echo (which one will be determined later by the study PIs), and Mini-Mental State Examination (MMSE).
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Studietype
Inschrijving (Geschat)
Fase
- Niet toepasbaar
Contacten en locaties
Studiecontact
- Naam: Georgiana Zou
- Telefoonnummer: +86 18918711140
- E-mail: georgiana.zou@medtronic.com
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
- Oudere volwassene
Accepteert gezonde vrijwilligers
Beschrijving
Inclusion Criteria:
- ≥65 years of age
- Planned implantation of a dual chamber pacemaker with physiological pacing
- Resting sinus heart rate ≤60 bpm, or average 24 hour Holter heart rate ≤60 bpm
- Documented history of hypertension or office systolic blood pressure ≥130 mmHg
Exclusion Criteria:
- Diagnosis of secondary hypertension
- Diagnosis of or possible concomitant heart failure, with ejection fraction ≤50%
- Paroxysmal, persistent, or permanent atrial fibrillation
- Status post CABG or PCI
- Structural heart disease
- Risk of ventricular tachyarrhythmia
- Severe hepatic or renal dysfunction
- Active acute infection
- Inability to sign informed consent
- Pregnancy or planned pregnancy during the study period
- Enrollment in other clinical studies that may affect the objectives of this study
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
- Primair doel: Behandeling
- Toewijzing: Gerandomiseerd
- Interventioneel model: Parallelle opdracht
- Masker: Dubbele
Wapens en interventies
Deelnemersgroep / Arm |
Interventie / Behandeling |
|---|---|
|
Experimenteel: Personalized Lower Rate Pacing Group (75 bpm)
Participants in this group will receive dual-chamber pacemaker implantation per standard clinical practice.
After implantation, the device lower rate will be programmed to a personalized pacing rate of 75 beats per minute according to the study protocol.
Ventricular diastolic function, cerebral blood flow, cognitive function, and blood pressure will be assessed during follow-up.
|
The intervention consists of programming the pacemaker lower rate to a personalized setting of 75 beats per minute (personalized lower rate, PLR), based on clinical assessment.
The control condition uses the standard pacemaker lower rate programmed at 50-60 beats per minute.
No additional procedures beyond routine clinical practice are introduced.
|
|
Actieve vergelijker: Conventional Lower Rate Pacing Group (60 bpm)
Participants in this group will receive dual-chamber pacemaker implantation per standard clinical practice.
After implantation, the device lower rate will be programmed to the conventional lower pacing rate of 60 beats per minute.
Outcome assessments during follow-up will be identical to those in the personalized pacing group.
|
The control intervention consists of programming the pacemaker lower rate to the standard clinical setting of 50-60 beats per minute, according to routine clinical practice.
No additional procedures or deviations from standard care are introduced.
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Change in Ventricular Diastolic Function and Cerebral Blood Flow
Tijdsspanne: Baseline to 6 months post-implantation
|
In hypertensive patients with sinus node dysfunction treated with dual chamber pacemaker implantation, compared with the control group (pacemaker lower rate 50-60 bpm), to verify whether ventricular diastolic function and cerebral blood flow can be improved by personalized lower rate pacing (PLR) (75 bpm).
|
Baseline to 6 months post-implantation
|
Secundaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Cardiac Structure and Function Assessment
Tijdsspanne: Baseline to 6 months post-implantation
|
To evaluate cardiovascular function using echocardiography and assess ventricular function, particularly diastolic function, using Doppler echocardiography.
|
Baseline to 6 months post-implantation
|
|
Cerebral Perfusion and Cognitive Function Assessment
Tijdsspanne: Baseline to 6 months post-implantation
|
To evaluate cerebral cortical blood distribution and white matter changes using magnetic resonance imaging (MRI), and to assess cognitive function using the Mini Mental State Examination (MMSE).
|
Baseline to 6 months post-implantation
|
|
Arterial Blood Pressure Assessment
Tijdsspanne: Baseline to 6 months post-implantation
|
To evaluate changes in arterial blood pressure using office blood pressure measurement and 24 hour ambulatory blood pressure monitoring.
|
Baseline to 6 months post-implantation
|
Medewerkers en onderzoekers
Publicaties en nuttige links
Algemene publicaties
- Meng L, Hou W, Chui J, Han R, Gelb AW. Cardiac Output and Cerebral Blood Flow: The Integrated Regulation of Brain Perfusion in Adult Humans. Anesthesiology. 2015 Nov;123(5):1198-208. doi: 10.1097/ALN.0000000000000872.
- Meyer M, LeWinter MM. Heart Rate and Heart Failure With Preserved Ejection Fraction: Time to Slow beta-Blocker Use? Circ Heart Fail. 2019 Aug;12(8):e006213. doi: 10.1161/CIRCHEARTFAILURE.119.006213. Epub 2019 Aug 1. No abstract available.
- Infeld M, Avram R, Wahlberg K, Silverman DN, Habel N, Lustgarten DL, Pletcher MJ, Olgin JE, Marcus GM, Meyer M. An approach towards individualized lower rate settings for pacemakers. Heart Rhythm O2. 2020 Dec;1(5):390-393. doi: 10.1016/j.hroo.2020.09.004. Epub 2020 Oct 6. No abstract available.
- Infeld M, Wahlberg K, Cicero J, Plante TB, Meagher S, Novelli A, Habel N, Krishnan AM, Silverman DN, LeWinter MM, Lustgarten DL, Meyer M. Effect of Personalized Accelerated Pacing on Quality of Life, Physical Activity, and Atrial Fibrillation in Patients With Preclinical and Overt Heart Failure With Preserved Ejection Fraction: The myPACE Randomized Clinical Trial. JAMA Cardiol. 2023 Mar 1;8(3):213-221. doi: 10.1001/jamacardio.2022.5320.
- Changes in 24-hour ambulatory systolic blood pressure following pacemaker implantation in patients with sinus node dysfunction. Presented at the APHRS 2025 Scientific Sessions; 2025; Poster presentation.
- Infeld M, et al. Allometric-Based Pacing Rate Improves Quality of Life in Bradycardia Patients. Presented at the HRS 2025 Scientific Sessions; 2025; Poster presentation.
- Infeld M, et al. A novel method to classify left bundle branch block with far-field intracardiac electrograms. Presented at the HRS 2025 Scientific Sessions; 2025; Poster presentation.
Studie record data
Bestudeer belangrijke data
Studie start (Geschat)
Primaire voltooiing (Geschat)
Studie voltooiing (Geschat)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Werkelijk)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Aanvullende relevante MeSH-voorwaarden
Andere studie-ID-nummers
- Allometric-Cerebral Study
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Informatie over medicijnen en apparaten, studiedocumenten
Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel
Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .