Deze pagina is automatisch vertaald en de nauwkeurigheid van de vertaling kan niet worden gegarandeerd. Raadpleeg de Engelse versie voor een brontekst.

3D Titanium Plates for Mandibular Body Fracture Fixation

11 juni 2026 bijgewerkt door: haitham Aldebass, Cairo University

The Use of 3d Titanium Plates With Two Different Profile Thickness for Open Reduction and Rigid Fixation of Mandibular Body Fracture : Randomised Clinical Trial

Mandibular body fracture pose significant challenges in maxillofacial surgery due to their frequency, potential for functional impairment, and aesthetic concerns. Open reduction and internal fixation (ORIF) using titanium plates and screws have revolutionized the management of mandibular fractures.

Recent advancements in technology have led to the development of patient-specific 3D titanium implants, offering the potential for improved anatomical fit and stability. Moreover, the concept of low-profile implants has gained traction, aiming to minimize soft tissue irritation and enhance patient comfort postoperatively.

Studie Overzicht

Toestand

Voltooid

Interventie / Behandeling

Gedetailleerde beschrijving

Facial trauma is common in road traffic accidents (RTA). Due to modernization, increased number of vehicles and failure to follow traffic rules are among various causes of facial trauma. Mandible is one of the frequently fractured bones in RTA. It has been observed that the most common sites of mandibular fracture are angle, body, and ramus.

The incidence of mandibular fracture ranges between 40% and 65% of all facial fractures and so are twice as common as fractures of the midfacial bones. Fractures of the angle of mandible can present with long term disabling sequelae and make up 23%-42% of all fractures in the mandible.

Other than traumatic injuries of the face, there are several factors leading to mandibular body fracture as direct impact or blunt force trauma, indirect trauma to the chin or side of the face, facial fractures, osteoporosis, tumors or cysts in the jawbone, some dental procedures, elderly population, and occupational hazards.

Long term sequel of untreated or poorly treated fractures includes various impairments such as functional, aesthetic, neurological and psychological. The main goal in the treatment of bone fracture is to predictably restore its preinjury anatomical form, with associated aesthetics and function. Techniques for treatment of mandibular fracture have evolved significantly in past decades. These techniques have ranged from closed reduction with maxillomandibular fixation, open reduction with wire osteosynthesis, to open reduction with either rigid internal fixation or adaptive miniplate fixation.

They are best managed by placing one single plate in neutral zone that is sub-apically along with arch bar as tension band. However, in case of severely displaced fractures, inadequate dentition or presence of associated fractures, there are changes in biomechanical vector of forces, which demands for rigid fixation like two plates or load-bearing fixation.

Monocortical plates stabilize the fracture two-dimensionally which can be inadequate fixation in the above-mentioned situations especially in load-bearing area that has led to development of 3D plates. 3D plates are quadrangular in geometry providing stability three-dimensionally due to its design and compact form which counteract against the torsional forces especially in intermental foramen region.

Open reduction and internal fixation (ORIF) using titanium plates and screws have become the standard of care for stabilizing displaced mandibular body fracture, facilitating proper alignment, and promoting optimal healing. However, the optimal design and thickness of these implants remain subjects of debate among maxillofacial surgeons.

Studietype

Ingrijpend

Inschrijving (Werkelijk)

18

Fase

  • Niet toepasbaar

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studie Locaties

    • Giza Governorate
      • Cairo, Giza Governorate, Egypte
        • Dentistery Hospital, Cairo Universiy

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Volwassen

Accepteert gezonde vrijwilligers

Ja

Beschrijving

Inclusion criteria:

  • Age ranging between 20-60 years.
  • Patients with mandibular body fractures requiring open reduction and fixation.
  • Patients with good health (ASA-I and ASA-II) without any contraindication for surgery or anesthesia.

Exclusion criteria:

  • Patients with pre-existing neurological or musculoskeletal disease.
  • Patients with infected fractures.
  • Patients with simultaneous condylar fracture.
  • Patients with regional malignancy.
  • Medically compromised patients.
  • Patients with blood diseases or severe renal disorders. Patients refuse to share in the study

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

  • Primair doel: Behandeling
  • Toewijzing: Gerandomiseerd
  • Interventioneel model: Parallelle opdracht
  • Masker: Geen (open label)

Wapens en interventies

Deelnemersgroep / Arm
Interventie / Behandeling
Actieve vergelijker: Group A (3d titanium plates of 2 mm):
About 9 patients suffered from mandibular fracture treated by using 3d titanium plates of 2 mm thickness.
to compare the 3D titanium plates with two different profile thickness for open reduction and fixation of mandibular body fracture.
Andere namen:
  • Open Reduction and Rigid Internal Fixation
Actieve vergelijker: Group B (3d titanium plates of 0.7 mm):
About 9 patients suffered from mandibular fracture treated by using 3d titanium plates of 0.7 mm thickness.
to compare the 3D titanium plates with two different profile thickness for open reduction and fixation of mandibular body fracture.
Andere namen:
  • Open Reduction and Rigid Internal Fixation

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Treatment of Postoperative pain
Tijdsspanne: 48 Hours from the operation
Treatment of the pain resulted from using 3d titanium plates with two different profile thickness for open reduction and fixation of mandibular body fracture by using a standardized pain scale.
48 Hours from the operation

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Incidence of postoperative Complications
Tijdsspanne: from1 week to 6 months
Secondary outcomes will be evaluated to assess the clinical effectiveness and safety of using 3D titanium plates with different profile thicknesses in the fixation of mandibular body fractures (as infection, malocclusion, and hardware-related complications).
from1 week to 6 months

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Onderzoekers

  • Studie stoel: Mohamed Atef, Professor, of Oral and Maxillofacial Surgery, Faculty of Dentistry - Kasr Al-Aini

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

15 december 2024

Primaire voltooiing (Werkelijk)

15 december 2025

Studie voltooiing (Werkelijk)

15 februari 2026

Studieregistratiedata

Eerst ingediend

11 juni 2026

Eerst ingediend dat voldeed aan de QC-criteria

11 juni 2026

Eerst geplaatst (Werkelijk)

16 juni 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

16 juni 2026

Laatste update ingediend die voldeed aan QC-criteria

11 juni 2026

Laatst geverifieerd

1 februari 2025

Meer informatie

Termen gerelateerd aan deze studie

Andere studie-ID-nummers

  • Mandibular Fracture Fixation

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

product vervaardigd in en geëxporteerd uit de V.S.

Ja

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .

Abonneren