Denne siden ble automatisk oversatt og nøyaktigheten av oversettelsen er ikke garantert. Vennligst referer til engelsk versjon for en kildetekst.

Application of Ship - Shaped Adhesive Tape Fixing in Patients Undergoing Tracheal Intubation

Application of Ship - Shaped Adhesive Tape Fixing in Patients Undergoing Tracheal

In order to evaluate the safety and value of the improved ship-shaped fixing on tracheal intubation patients and provide theoretical basis for clinical therapy, we conducted this research to compare the fixed effectiveness, complications, nursing workload and medical expenses about application of ship-shaped adhesive tape fixation on patient undergoing tracheal intubation.

Studieoversikt

Detaljert beskrivelse

the fixed effectiveness:Incidence of catheter displacement,Incidence of unplanned extubation.

complications:Incidence f skin damage,Oral care effect,Incidence of ventilator-associated pneumonia.

nursing workload:Oral care is time-consuming medical expenses :Material economic cost

Studietype

Intervensjonell

Registrering (Faktiske)

134

Fase

  • Ikke aktuelt

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiesteder

    • Zhejiang
      • Hangzhou, Zhejiang, Kina, 310000
        • The Second Affiliated Hospital of Zhejiang University

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

  • Barn
  • Voksen
  • Eldre voksen

Tar imot friske frivillige

Nei

Kjønn som er kvalifisert for studier

Alle

Beskrivelse

Inclusion Criteria:

  • Patients with SICU intubation had been intubated for <8h at the time of entry (the interval of oral care was 8h);
  • Patients with brain diseases or septic shock caused by abdominal infection;
  • There was no pulmonary infection before endotracheal intubation.
  • Facial skin integrity;
  • Good oral cavity: no odor, no residue, no oral diseases, oral mucosa integrity;
  • Informed consent is given by the family members and the informed consent is signed;
  • No adhesive tape allergy.

Exclusion Criteria:

  • Oral injury caused by suction;
  • Endotracheal intubation time < 48 h;
  • In the experiment is not willing to carry on the experiment, quit voluntarily.

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

  • Primært formål: Annen
  • Tildeling: Randomisert
  • Intervensjonsmodell: Parallell tildeling
  • Masking: Trippel

Våpen og intervensjoner

Deltakergruppe / Arm
Intervensjon / Behandling
Eksperimentell: 3M tape ship-shaped combined with strap fixing method
  1. Cutting method of 3M adhesive tape of ship shape: cut a piece of 20cm×3cm elastic adhesive tape, fold it in half to form a rectangle of 10cm×3cm, cut 5cm straight line from the middle point of the crease, cut it at an Angle of 45°, fold and open the 3M elastic adhesive tape in half, which is the adhesive tape required for fixing. The final shape is similar to that of a ship, and it is named as 3M adhesive tape of ship shape.
  2. Fixation method: The ship shape with 3M adhesive tape was pasted upward on the opposite cheek (near zygomatic), and the endotracheal intubation was wound around for two rounds and then glued to the near cheek (near zygomatic).Put the tooth pad next to the endotracheal intubation and wrap the tooth pad and catheter together for two turns with a short 3M adhesive tape of 12cm×1.5cm.Finally, fasten it with a lacing.
During fixation, the endotracheal intubation and dental pad were located in the center of the mouth, and one end of one piece of medical cloth adhesive was pasted on the patient's cheek near the side. When it reached one side of the mouth, the endotracheal intubation and dental pad were wound around twice, and then the other side of the adhesive tape was pasted on the cheek opposite the side from the other side of the mouth,The other is fixed in reverse with the same sticking method, and the two pieces of adhesive tape are finally crossed and fixed at the corners of the mouth.Finally, fasten it with a lacing
Ingen inngripen: traditional X-shaped tape and string fixing

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
the fixed effectiveness of endotracheal intubation
Tidsramme: 34 weeks
The tube displacement rate,
34 weeks

Sekundære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Complications associated with endotracheal intubation fixation
Tidsramme: 34 weeks
Unplanned extubation,the occurrence of facial adhesive related skin injury,Effect of oral care
34 weeks

Andre resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Economic indicators
Tidsramme: 34 weeks
The cost of the tape required for the fixation
34 weeks
Nursing workload
Tidsramme: 34 weeks
Oral care takes a few minutes
34 weeks

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Faktiske)

1. april 2018

Primær fullføring (Faktiske)

31. desember 2018

Studiet fullført (Faktiske)

31. desember 2018

Datoer for studieregistrering

Først innsendt

17. juni 2020

Først innsendt som oppfylte QC-kriteriene

11. januar 2021

Først lagt ut (Faktiske)

13. januar 2021

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

13. januar 2021

Siste oppdatering sendt inn som oppfylte QC-kriteriene

11. januar 2021

Sist bekreftet

1. januar 2021

Mer informasjon

Begreper knyttet til denne studien

Andre studie-ID-numre

  • 2018-144

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .

Abonnere