Application of Ship - Shaped Adhesive Tape Fixing in Patients Undergoing Tracheal Intubation

Application of Ship - Shaped Adhesive Tape Fixing in Patients Undergoing Tracheal

In order to evaluate the safety and value of the improved ship-shaped fixing on tracheal intubation patients and provide theoretical basis for clinical therapy, we conducted this research to compare the fixed effectiveness, complications, nursing workload and medical expenses about application of ship-shaped adhesive tape fixation on patient undergoing tracheal intubation.

Panoramica dello studio

Descrizione dettagliata

the fixed effectiveness:Incidence of catheter displacement,Incidence of unplanned extubation.

complications:Incidence f skin damage,Oral care effect,Incidence of ventilator-associated pneumonia.

nursing workload:Oral care is time-consuming medical expenses :Material economic cost

Tipo di studio

Interventistico

Iscrizione (Effettivo)

134

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

    • Zhejiang
      • Hangzhou, Zhejiang, Cina, 310000
        • The Second Affiliated Hospital of Zhejiang University

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

  • Bambino
  • Adulto
  • Adulto più anziano

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • Patients with SICU intubation had been intubated for <8h at the time of entry (the interval of oral care was 8h);
  • Patients with brain diseases or septic shock caused by abdominal infection;
  • There was no pulmonary infection before endotracheal intubation.
  • Facial skin integrity;
  • Good oral cavity: no odor, no residue, no oral diseases, oral mucosa integrity;
  • Informed consent is given by the family members and the informed consent is signed;
  • No adhesive tape allergy.

Exclusion Criteria:

  • Oral injury caused by suction;
  • Endotracheal intubation time < 48 h;
  • In the experiment is not willing to carry on the experiment, quit voluntarily.

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Altro
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione parallela
  • Mascheramento: Triplicare

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: 3M tape ship-shaped combined with strap fixing method
  1. Cutting method of 3M adhesive tape of ship shape: cut a piece of 20cm×3cm elastic adhesive tape, fold it in half to form a rectangle of 10cm×3cm, cut 5cm straight line from the middle point of the crease, cut it at an Angle of 45°, fold and open the 3M elastic adhesive tape in half, which is the adhesive tape required for fixing. The final shape is similar to that of a ship, and it is named as 3M adhesive tape of ship shape.
  2. Fixation method: The ship shape with 3M adhesive tape was pasted upward on the opposite cheek (near zygomatic), and the endotracheal intubation was wound around for two rounds and then glued to the near cheek (near zygomatic).Put the tooth pad next to the endotracheal intubation and wrap the tooth pad and catheter together for two turns with a short 3M adhesive tape of 12cm×1.5cm.Finally, fasten it with a lacing.
During fixation, the endotracheal intubation and dental pad were located in the center of the mouth, and one end of one piece of medical cloth adhesive was pasted on the patient's cheek near the side. When it reached one side of the mouth, the endotracheal intubation and dental pad were wound around twice, and then the other side of the adhesive tape was pasted on the cheek opposite the side from the other side of the mouth,The other is fixed in reverse with the same sticking method, and the two pieces of adhesive tape are finally crossed and fixed at the corners of the mouth.Finally, fasten it with a lacing
Nessun intervento: traditional X-shaped tape and string fixing

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
the fixed effectiveness of endotracheal intubation
Lasso di tempo: 34 weeks
The tube displacement rate,
34 weeks

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Complications associated with endotracheal intubation fixation
Lasso di tempo: 34 weeks
Unplanned extubation,the occurrence of facial adhesive related skin injury,Effect of oral care
34 weeks

Altre misure di risultato

Misura del risultato
Misura Descrizione
Lasso di tempo
Economic indicators
Lasso di tempo: 34 weeks
The cost of the tape required for the fixation
34 weeks
Nursing workload
Lasso di tempo: 34 weeks
Oral care takes a few minutes
34 weeks

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

1 aprile 2018

Completamento primario (Effettivo)

31 dicembre 2018

Completamento dello studio (Effettivo)

31 dicembre 2018

Date di iscrizione allo studio

Primo inviato

17 giugno 2020

Primo inviato che soddisfa i criteri di controllo qualità

11 gennaio 2021

Primo Inserito (Effettivo)

13 gennaio 2021

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

13 gennaio 2021

Ultimo aggiornamento inviato che soddisfa i criteri QC

11 gennaio 2021

Ultimo verificato

1 gennaio 2021

Maggiori informazioni

Termini relativi a questo studio

Altri numeri di identificazione dello studio

  • 2018-144

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

No

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Sottoscrivi