Denne siden ble automatisk oversatt og nøyaktigheten av oversettelsen er ikke garantert. Vennligst referer til engelsk versjon for en kildetekst.

Reading Performance in Patients With Acrysof IQ Vivity Versus Acrysof IQ

4. januar 2022 oppdatert av: Prim. Prof. Dr. Oliver Findl, MBA, Vienna Institute for Research in Ocular Surgery

Assessment of Reading Performance in Patients With Acrysof IQ Vivity Toric or Non-toric vs Monofocal Acrysof IQ Toric or Non-toric IOL

Comparison of the visual function and reading performance between the Acrysof IQ Vivity IOL, an EDOF IOL, and the monofocal Acrysof IQ.

Studieoversikt

Status

Rekruttering

Forhold

Detaljert beskrivelse

With increasing demands of patients concerning their visual function after cataract surgery, a variety of advanced technology intraocular lenses (IOL) have become available in the last years. Various developments aim at a reduced spectacle independence for patients after cataract or refractive lens surgery.

Novel technology for providing an extended depth of focus (EDOF) has been developed to account for unmet needs of patients. A novel EDOF IOL, the Acrysof IQ Vivity, has two surface transition elements that work simultaneously by stretching and shifting the wavefront to create a continuous extended focal range instead of multiple focal points.

To assess the performance of such an IOL technology, most studies assess visual acuity at different distances from far, to intermediate up to near. Since most activites with digital devices implicate reading, it is not surprising that reading difficulty is the most common complaint among individuals experiencing visual disturbances with multifocal designs.

Reading ability is usually evaluated using various reading tests that assess reading speed and reading acuity defined as the print size that can stell be read with sufficient speed. However, one of the fundamental problems of these tests is that reading speed is also influenced by the average amount of time that a patient reads as well as the language of the text, whether it is the first or second language.

A novel method to analyse reading performance that appears to be more objective and less reliant on the cognitive abilities of the patient is the observation of the reading pattern using a high-speed eye-tracking system that analyses eye fixations during the reading test. In previous studies we have seen that several aspects of this reading patter, i.e. fixation duration and fixation frequency, appear to correlate with the reading performance overall and can be differentially used to discriminate between cognitive and visuo-motor processing.

Hence, the aim of this study is to assess the visual function and reading performance with an EDOF IOL (Acrysof IQ Vivity) compared to a standard monofocal IOL (Acrysof IQ).

136 eyes of 68 patients will be included into this study. According to the randomization, 34 patients will be implanted with the Acrysof IQ Vivity in both eyes and the other 34 patients will be implanted with the Acrysof IQ in both eyes. A follow-up examination will be performed at 3 months postoperative. During this visit a slitlamp examination, biometry and tomography of the eye, refraction and visual acuity assessment, an OCT examination, a retroillumination photogrypha, reading speed analysis and halometry will be performed.

Studietype

Intervensjonell

Registrering (Forventet)

68

Fase

  • Ikke aktuelt

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiekontakt

  • Navn: Natascha Bayer, MSc
  • Telefonnummer: 57564 01 91021
  • E-post: office@viros.at

Studer Kontakt Backup

  • Navn: Sahand Amir-Asgari, MD
  • Telefonnummer: 57564 01 91021
  • E-post: office@viros.at

Studiesteder

      • Vienna, Østerrike, 1140
        • Rekruttering
        • Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch Hospital Vienna
        • Ta kontakt med:
          • Natascha Bayer, MSc
          • Telefonnummer: 57564 01 91021
          • E-post: office@viros.at
        • Ta kontakt med:
          • Sahand Amir-Asgari, MD
          • Telefonnummer: 57564 01 91021
          • E-post: office@viros.at

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

21 år til 105 år (Voksen, Eldre voksen)

Tar imot friske frivillige

Nei

Kjønn som er kvalifisert for studier

Alle

Beskrivelse

Inclusion Criteria:

  • Cataract
  • Stereopsis
  • age 21 and older
  • regular corneal astigmatism of up to 3.0 D
  • written informed consent prior to surgery
  • normal findings in the medical history and physical examination unless the investigator considers an abnormality to be clinically irrelevant
  • availability, willingness and sufficient cognitive awareness to comply with examination procedures
  • german as mother-tongue
  • calculated IOL power needed is below 15.0 D or above 25.0 D (no high myopia or high hypermetropia will be recruited)

Exclusion Criteria:

  • relevant other ophthalmic diseases such as: pseudoexfoliation, glaucoma, traumatic cataract, corneal scars, and other co-morbidity that could affect capsule bag stability (e.g. Marfan syndrome) or retinal diseases affecting visual acuity (AMD, Macular Pucker, post-operative macular edema...)
  • amblyopia
  • contact lenses
  • irregular corneal astigmatism on corneal topography
  • postoperative subjective refraction smaller/ higher than or 0.75 D
  • pregnancy (pregnancy test will be taken preoperatively in women of reproductive age)

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

  • Primært formål: Behandling
  • Tildeling: Randomisert
  • Intervensjonsmodell: Parallell tildeling
  • Masking: Dobbelt

Våpen og intervensjoner

Deltakergruppe / Arm
Intervensjon / Behandling
Eksperimentell: Acrysof IQ Vivity
Patient will receive the enhanced depth of focus IOL during cataract surgery
Acrysof IQ Vivity, enhanced depth of focus IOL
Eksperimentell: Acrysof IQ
Patiet will receive the monofocal IOL during cataract surgery
Acrysof IQ, monofocal IOL

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Reading speed
Tidsramme: 24 months
reading speed will be assessed with the Eyetracker device at 66 centimetres and will be compared between the EDOF IOL and the monofocal IOL
24 months

Sekundære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Visual acuity
Tidsramme: 24 months
Visual acuity will be assessed using the ETDRS charts and will be compared between the EDOF IOLs and the monofocal IOLs
24 months

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Faktiske)

3. januar 2022

Primær fullføring (Forventet)

3. januar 2023

Studiet fullført (Forventet)

3. januar 2024

Datoer for studieregistrering

Først innsendt

4. januar 2022

Først innsendt som oppfylte QC-kriteriene

4. januar 2022

Først lagt ut (Faktiske)

18. januar 2022

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

18. januar 2022

Siste oppdatering sendt inn som oppfylte QC-kriteriene

4. januar 2022

Sist bekreftet

1. januar 2022

Mer informasjon

Begreper knyttet til denne studien

Ytterligere relevante MeSH-vilkår

Andre studie-ID-numre

  • Vivity

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

NEI

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .

Abonnere