- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT05194657
Reading Performance in Patients With Acrysof IQ Vivity Versus Acrysof IQ
Assessment of Reading Performance in Patients With Acrysof IQ Vivity Toric or Non-toric vs Monofocal Acrysof IQ Toric or Non-toric IOL
Visão geral do estudo
Status
Condições
Intervenção / Tratamento
Descrição detalhada
With increasing demands of patients concerning their visual function after cataract surgery, a variety of advanced technology intraocular lenses (IOL) have become available in the last years. Various developments aim at a reduced spectacle independence for patients after cataract or refractive lens surgery.
Novel technology for providing an extended depth of focus (EDOF) has been developed to account for unmet needs of patients. A novel EDOF IOL, the Acrysof IQ Vivity, has two surface transition elements that work simultaneously by stretching and shifting the wavefront to create a continuous extended focal range instead of multiple focal points.
To assess the performance of such an IOL technology, most studies assess visual acuity at different distances from far, to intermediate up to near. Since most activites with digital devices implicate reading, it is not surprising that reading difficulty is the most common complaint among individuals experiencing visual disturbances with multifocal designs.
Reading ability is usually evaluated using various reading tests that assess reading speed and reading acuity defined as the print size that can stell be read with sufficient speed. However, one of the fundamental problems of these tests is that reading speed is also influenced by the average amount of time that a patient reads as well as the language of the text, whether it is the first or second language.
A novel method to analyse reading performance that appears to be more objective and less reliant on the cognitive abilities of the patient is the observation of the reading pattern using a high-speed eye-tracking system that analyses eye fixations during the reading test. In previous studies we have seen that several aspects of this reading patter, i.e. fixation duration and fixation frequency, appear to correlate with the reading performance overall and can be differentially used to discriminate between cognitive and visuo-motor processing.
Hence, the aim of this study is to assess the visual function and reading performance with an EDOF IOL (Acrysof IQ Vivity) compared to a standard monofocal IOL (Acrysof IQ).
136 eyes of 68 patients will be included into this study. According to the randomization, 34 patients will be implanted with the Acrysof IQ Vivity in both eyes and the other 34 patients will be implanted with the Acrysof IQ in both eyes. A follow-up examination will be performed at 3 months postoperative. During this visit a slitlamp examination, biometry and tomography of the eye, refraction and visual acuity assessment, an OCT examination, a retroillumination photogrypha, reading speed analysis and halometry will be performed.
Tipo de estudo
Inscrição (Antecipado)
Estágio
- Não aplicável
Contactos e Locais
Contato de estudo
- Nome: Natascha Bayer, MSc
- Número de telefone: 57564 01 91021
- E-mail: office@viros.at
Estude backup de contato
- Nome: Sahand Amir-Asgari, MD
- Número de telefone: 57564 01 91021
- E-mail: office@viros.at
Locais de estudo
-
-
-
Vienna, Áustria, 1140
- Recrutamento
- Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch Hospital Vienna
-
Contato:
- Natascha Bayer, MSc
- Número de telefone: 57564 01 91021
- E-mail: office@viros.at
-
Contato:
- Sahand Amir-Asgari, MD
- Número de telefone: 57564 01 91021
- E-mail: office@viros.at
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Descrição
Inclusion Criteria:
- Cataract
- Stereopsis
- age 21 and older
- regular corneal astigmatism of up to 3.0 D
- written informed consent prior to surgery
- normal findings in the medical history and physical examination unless the investigator considers an abnormality to be clinically irrelevant
- availability, willingness and sufficient cognitive awareness to comply with examination procedures
- german as mother-tongue
- calculated IOL power needed is below 15.0 D or above 25.0 D (no high myopia or high hypermetropia will be recruited)
Exclusion Criteria:
- relevant other ophthalmic diseases such as: pseudoexfoliation, glaucoma, traumatic cataract, corneal scars, and other co-morbidity that could affect capsule bag stability (e.g. Marfan syndrome) or retinal diseases affecting visual acuity (AMD, Macular Pucker, post-operative macular edema...)
- amblyopia
- contact lenses
- irregular corneal astigmatism on corneal topography
- postoperative subjective refraction smaller/ higher than or 0.75 D
- pregnancy (pregnancy test will be taken preoperatively in women of reproductive age)
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
- Finalidade Principal: Tratamento
- Alocação: Randomizado
- Modelo Intervencional: Atribuição Paralela
- Mascaramento: Dobro
Armas e Intervenções
Grupo de Participantes / Braço |
Intervenção / Tratamento |
|---|---|
|
Experimental: Acrysof IQ Vivity
Patient will receive the enhanced depth of focus IOL during cataract surgery
|
Acrysof IQ Vivity, enhanced depth of focus IOL
|
|
Experimental: Acrysof IQ
Patiet will receive the monofocal IOL during cataract surgery
|
Acrysof IQ, monofocal IOL
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Reading speed
Prazo: 24 months
|
reading speed will be assessed with the Eyetracker device at 66 centimetres and will be compared between the EDOF IOL and the monofocal IOL
|
24 months
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Visual acuity
Prazo: 24 months
|
Visual acuity will be assessed using the ETDRS charts and will be compared between the EDOF IOLs and the monofocal IOLs
|
24 months
|
Colaboradores e Investigadores
Patrocinador
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Antecipado)
Conclusão do estudo (Antecipado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- Vivity
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .