- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT05194657
Reading Performance in Patients With Acrysof IQ Vivity Versus Acrysof IQ
Assessment of Reading Performance in Patients With Acrysof IQ Vivity Toric or Non-toric vs Monofocal Acrysof IQ Toric or Non-toric IOL
Przegląd badań
Status
Warunki
Interwencja / Leczenie
Szczegółowy opis
With increasing demands of patients concerning their visual function after cataract surgery, a variety of advanced technology intraocular lenses (IOL) have become available in the last years. Various developments aim at a reduced spectacle independence for patients after cataract or refractive lens surgery.
Novel technology for providing an extended depth of focus (EDOF) has been developed to account for unmet needs of patients. A novel EDOF IOL, the Acrysof IQ Vivity, has two surface transition elements that work simultaneously by stretching and shifting the wavefront to create a continuous extended focal range instead of multiple focal points.
To assess the performance of such an IOL technology, most studies assess visual acuity at different distances from far, to intermediate up to near. Since most activites with digital devices implicate reading, it is not surprising that reading difficulty is the most common complaint among individuals experiencing visual disturbances with multifocal designs.
Reading ability is usually evaluated using various reading tests that assess reading speed and reading acuity defined as the print size that can stell be read with sufficient speed. However, one of the fundamental problems of these tests is that reading speed is also influenced by the average amount of time that a patient reads as well as the language of the text, whether it is the first or second language.
A novel method to analyse reading performance that appears to be more objective and less reliant on the cognitive abilities of the patient is the observation of the reading pattern using a high-speed eye-tracking system that analyses eye fixations during the reading test. In previous studies we have seen that several aspects of this reading patter, i.e. fixation duration and fixation frequency, appear to correlate with the reading performance overall and can be differentially used to discriminate between cognitive and visuo-motor processing.
Hence, the aim of this study is to assess the visual function and reading performance with an EDOF IOL (Acrysof IQ Vivity) compared to a standard monofocal IOL (Acrysof IQ).
136 eyes of 68 patients will be included into this study. According to the randomization, 34 patients will be implanted with the Acrysof IQ Vivity in both eyes and the other 34 patients will be implanted with the Acrysof IQ in both eyes. A follow-up examination will be performed at 3 months postoperative. During this visit a slitlamp examination, biometry and tomography of the eye, refraction and visual acuity assessment, an OCT examination, a retroillumination photogrypha, reading speed analysis and halometry will be performed.
Typ studiów
Zapisy (Oczekiwany)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Kontakt w sprawie studiów
- Nazwa: Natascha Bayer, MSc
- Numer telefonu: 57564 01 91021
- E-mail: office@viros.at
Kopia zapasowa kontaktu do badania
- Nazwa: Sahand Amir-Asgari, MD
- Numer telefonu: 57564 01 91021
- E-mail: office@viros.at
Lokalizacje studiów
-
-
-
Vienna, Austria, 1140
- Rekrutacyjny
- Vienna Institute for Research in Ocular Surgery (VIROS), Hanusch Hospital Vienna
-
Kontakt:
- Natascha Bayer, MSc
- Numer telefonu: 57564 01 91021
- E-mail: office@viros.at
-
Kontakt:
- Sahand Amir-Asgari, MD
- Numer telefonu: 57564 01 91021
- E-mail: office@viros.at
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Opis
Inclusion Criteria:
- Cataract
- Stereopsis
- age 21 and older
- regular corneal astigmatism of up to 3.0 D
- written informed consent prior to surgery
- normal findings in the medical history and physical examination unless the investigator considers an abnormality to be clinically irrelevant
- availability, willingness and sufficient cognitive awareness to comply with examination procedures
- german as mother-tongue
- calculated IOL power needed is below 15.0 D or above 25.0 D (no high myopia or high hypermetropia will be recruited)
Exclusion Criteria:
- relevant other ophthalmic diseases such as: pseudoexfoliation, glaucoma, traumatic cataract, corneal scars, and other co-morbidity that could affect capsule bag stability (e.g. Marfan syndrome) or retinal diseases affecting visual acuity (AMD, Macular Pucker, post-operative macular edema...)
- amblyopia
- contact lenses
- irregular corneal astigmatism on corneal topography
- postoperative subjective refraction smaller/ higher than or 0.75 D
- pregnancy (pregnancy test will be taken preoperatively in women of reproductive age)
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Randomizowane
- Model interwencyjny: Przydział równoległy
- Maskowanie: Podwójnie
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
---|---|
Eksperymentalny: Acrysof IQ Vivity
Patient will receive the enhanced depth of focus IOL during cataract surgery
|
Acrysof IQ Vivity, enhanced depth of focus IOL
|
Eksperymentalny: Acrysof IQ
Patiet will receive the monofocal IOL during cataract surgery
|
Acrysof IQ, monofocal IOL
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
---|---|---|
Reading speed
Ramy czasowe: 24 months
|
reading speed will be assessed with the Eyetracker device at 66 centimetres and will be compared between the EDOF IOL and the monofocal IOL
|
24 months
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
---|---|---|
Visual acuity
Ramy czasowe: 24 months
|
Visual acuity will be assessed using the ETDRS charts and will be compared between the EDOF IOLs and the monofocal IOLs
|
24 months
|
Współpracownicy i badacze
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Oczekiwany)
Ukończenie studiów (Oczekiwany)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- Vivity
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .