Clinical Validation of Portable Electronic Stethoscope for Detecting VHD
Clinical Validation of Portable Electronic Stethoscope for Detecting Valvular Heart Disease
The goal of this observational study is to evaluate accuracy of portable electronic stethoscope and machine learning-based diagnostic algorithms for detecting the disease in people with valvular heart disease and healthy controls. The main question it aims to answer is:
Is portable electronic stethoscope and machine learning-based diagnostic algorithms allow accurate detection of valvular heart disease?
Researchers will compare diagnostic algorithm's predictions with the clinicians' predictions to see if the diagnostic results are accurate.
Participants will
- take echocardiogram
- take electrocardiogram using BPM Core
- get the heart auscultation data measured via electronic stethoscope
Studieoversikt
Detaljert beskrivelse
Studietype
Registrering (Antatt)
Kontakter og plasseringer
Studiekontakt
- Navn: Chun Ka Wong, Clinical Assistant Professor
- Telefonnummer: 852 2255 3597
- E-post: wongeck@hku.hk
Studiesteder
-
-
Pok Fu Lam Rd.
-
Hong Kong, Pok Fu Lam Rd., Hong Kong
- Rekruttering
- Queen Mary Hospital
-
Ta kontakt med:
- Telefonnummer: 22553838
- E-post: qmh_enquiry@ha.org.hk
-
-
Deltakelseskriterier
Kvalifikasjonskriterier
Alder som er kvalifisert for studier
- Voksen
- Eldre voksen
Tar imot friske frivillige
Prøvetakingsmetode
Studiepopulasjon
Beskrivelse
Inclusion Criteria:
- Voluntarily agrees to participate by proving written informed consent
- Have echocardiography done within 5 years
Exclusion Criteria:
- Mechanical heart valve
- Adult congenital heart disease
Studieplan
Hvordan er studiet utformet?
Designdetaljer
Kohorter og intervensjoner
Gruppe / Kohort |
Intervensjon / Behandling |
|---|---|
|
Styre
|
Heart auscultation data will be collected from the patients in 5 different groups using BPM Core
|
|
Aortic stenosis
|
Heart auscultation data will be collected from the patients in 5 different groups using BPM Core
|
|
Mitral stenosis
|
Heart auscultation data will be collected from the patients in 5 different groups using BPM Core
|
|
Mitral regurgitation
|
Heart auscultation data will be collected from the patients in 5 different groups using BPM Core
|
|
Tricuspid regurgitation
|
Heart auscultation data will be collected from the patients in 5 different groups using BPM Core
|
Hva måler studien?
Primære resultatmål
Resultatmål |
Tiltaksbeskrivelse |
Tidsramme |
|---|---|---|
|
Accuracy of valvular heart disease diagnosis using portable electronic stethoscope and machine learning-based diagnostic algorithms.
Tidsramme: from admission to discharge, up to 1 hour
|
Comparison between the algorithm diagnosis to those made by the clinicians using the collected heart auscultation data and echocardiogram results
|
from admission to discharge, up to 1 hour
|
Samarbeidspartnere og etterforskere
Sponsor
Studierekorddatoer
Studer hoveddatoer
Studiestart (Faktiske)
Primær fullføring (Faktiske)
Studiet fullført (Antatt)
Datoer for studieregistrering
Først innsendt
Først innsendt som oppfylte QC-kriteriene
Først lagt ut (Faktiske)
Oppdateringer av studieposter
Sist oppdatering lagt ut (Faktiske)
Siste oppdatering sendt inn som oppfylte QC-kriteriene
Sist bekreftet
Mer informasjon
Begreper knyttet til denne studien
Ytterligere relevante MeSH-vilkår
Andre studie-ID-numre
- PESVAH
Legemiddel- og utstyrsinformasjon, studiedokumenter
Studerer et amerikansk FDA-regulert medikamentprodukt
Studerer et amerikansk FDA-regulert enhetsprodukt
produkt produsert i og eksportert fra USA
Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .