Handheld 3D Lumbar Spine Navigation: A Clinical Validation Study RM002
Currently, at UVA, handheld ultrasound devices (like those used to view an unborn baby) are only two dimensional. The Accuro is a three dimensional handheld ultrasound device. This device uses sound waves to create pictures of the spine in three dimensions. This may allow the physician to view the spine in more detail for procedures such as spinal anesthesia and other diagnostic procedures. Epidural analgesia is the mainstay procedure for the management of labor pain. The precise placement of a needle or catheter in proximity to landmarks of the spinal bone anatomy is required for the procedure to succeed. The current standard of care is called the 'blind approach' (i.e. without medical imaging) and involves a physician manually palpating a patient's back to locate spinal bone landmarks. The needle is then inserted with respect to the location of the landmarks and inserted until a loss-of-resistance is manually detected. This approach, while most common, has been associated with success rates as low as 68% in obese patients (2).
Alternative methods have been investigated for this problem, including ultrasound (US) guidance, which offers real-time imaging. Several studies have demonstrated ultrasound's efficacy for spinal anesthesia (1-6). However, standard US systems are engineered to image soft tissue rather than bone structures, with the consequence that bone is imaged poorly. US images are often degraded by a number of noise sources including speckle noise, reverberations and off-axis scattering, particularly when bone is present, making visualization of bone anatomy features difficult. Moreover, arranging access to ultrasound for the purpose of spinal anesthesia alone is cumbersome. Thus, the efficacy of guided spinal anesthesia and diagnostic procedures using standard ultrasound systems is limited and the benefits that it offers are heavily dependent on the user's familiarity and skill with ultrasonography (4).
Recently, new medical imaging technologies have been developed at Rivanna Medical, LLC to address the significant clinical need for technological advances that improve the placement of spinal anesthesia, epidural analgesia and other diagnostic procedures. The Accuro is a pocket-sized and battery operated ultrasound instrument that incorporates new signal processing-based technologies for enhanced bone imaging including 3D navigation of the lumbar spine. The device is a single self-contained unit consisting of an ultrasound system, ultrasound probe, and rotatable touchscreen display. The instrument enables a SpineView3D™ technology to facilitate spinal anesthesia guidance with real-time 3D navigation of the lumbar spine anatomy.
SpineView3D™ technology facilitates image interpretation of individual 2D lumbar spine scans by automating spinal bone landmark detection and depth measurements and providing a real-time assessment of scan plane orientation in 3D. SpineView3D™ makes image interpretation and measurements of the lumbar spine anatomy simple, quick, and easy. Real-time 2D scans from either SpineView3D™ or general-purpose bone presets are formed using patent-pending BoneEnhance+™ technology. The BoneEnhance+™ technology provides images of bone anatomy at greater bone-to-tissue contrast compared with conventional ultrasound image reconstructions.
Przegląd badań
Status
Warunki
Typ studiów
Zapisy (Rzeczywisty)
Kontakty i lokalizacje
Lokalizacje studiów
-
-
Virginia
-
Charlottesville, Virginia, Stany Zjednoczone, 22908
- University of Virginia Health System
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
Akceptuje zdrowych ochotników
Płeć kwalifikująca się do nauki
Metoda próbkowania
Badana populacja
Opis
Inclusion Criteria:
Patients between the ages of 18 and 40 presenting for delivery and planning epidural anesthesia
- ASA-1 and ASA-2
- BMI > 30
Exclusion Criteria:
Patients with known spinal deformities allergies to ultrasound gel
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
Kohorty i interwencje
Grupa / Kohorta |
Interwencja / Leczenie |
|---|---|
|
Control group (CG):
Standard practice group
|
Standard practice group
Inne nazwy:
|
|
Ultrasound group (UG):
SpineView3D™ anatomical "scouting" approach
|
SpineView3D™ anatomical "scouting" approach
Inne nazwy:
subject will be scanned with 'Accuro SpineView3D
Inne nazwy:
|
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
Success rates:
Ramy czasowe: 1 day
|
defined as successful epidural administration on the first needle insertion attempt.
|
1 day
|
Współpracownicy i badacze
Sponsor
Współpracownicy
Śledczy
- Główny śledczy: Mohammed Tiouririne, MD, UVA Health System
Publikacje i pomocne linki
Publikacje ogólne
- Chin KJ, Perlas A, Chan V, Brown-Shreves D, Koshkin A, Vaishnav V. Ultrasound imaging facilitates spinal anesthesia in adults with difficult surface anatomic landmarks. Anesthesiology. 2011 Jul;115(1):94-101. doi: 10.1097/ALN.0b013e31821a8ad4.
- Vallejo MC, Phelps AL, Singh S, Orebaugh SL, Sah N. Ultrasound decreases the failed labor epidural rate in resident trainees. Int J Obstet Anesth. 2010 Oct;19(4):373-8. doi: 10.1016/j.ijoa.2010.04.002. Epub 2010 Aug 8.
- Grau T, Bartusseck E, Conradi R, Martin E, Motsch J. Ultrasound imaging improves learning curves in obstetric epidural anesthesia: a preliminary study. Can J Anaesth. 2003 Dec;50(10):1047-50. doi: 10.1007/BF03018371.
- Grau T, Leipold RW, Conradi R, Martin E. Ultrasound control for presumed difficult epidural puncture. Acta Anaesthesiol Scand. 2001 Jul;45(6):766-71. doi: 10.1034/j.1399-6576.2001.045006766.x.
- Chin KJ, Karmakar MK, Peng P. Ultrasonography of the adult thoracic and lumbar spine for central neuraxial blockade. Anesthesiology. 2011 Jun;114(6):1459-85. doi: 10.1097/ALN.0b013e318210f9f8.
- Karmakar MK. Ultrasound for central neuroaxial blocks. Techniques in regional anesthesia and pain management 2009;13:161-70.
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Oszacować)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Inne numery identyfikacyjne badania
- Rivanna Clin-002
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .
Badania kliniczne na Control group (CG): standard practice
-
Sheikh Zayed Medical CollegeAktywny, nie rekrutującyNacięcie krocza rozszerzone przez zranieniePakistan
-
Federico II UniversityZakończonyZdrowy | Nadwaga i otyłośćWłochy
-
ZOLL Circulation, Inc., USAPhilips Healthcare; Lund University HospitalZakończonyOstry zawał mięśnia sercowego przedniegoSzwecja
-
Fu Jen Catholic University HospitalRekrutacyjnyPrzewlekła choroba nerek (CKD) | Przewlekła choroba nerek w stadium 1-3Tajwan
-
Caregen Co. Ltd.Jeszcze nie rekrutacja
-
Zagazig UniversityZakończonyPowikłania cięcia cesarskiegoArabia Saudyjska
-
University of California, Los AngelesNational Institute of Neurological Disorders and Stroke (NINDS)ZakończonyOstry udar niedokrwiennyStany Zjednoczone
-
University of ZurichSchweizerischer NationalfondsRekrutacyjny
-
Centre Hospitalier Universitaire Saint PierreRekrutacyjnyChirurgia szczękowo-twarzowa | Chirurgia głowy i szyiBelgia