Handheld 3D Lumbar Spine Navigation: A Clinical Validation Study RM002
Currently, at UVA, handheld ultrasound devices (like those used to view an unborn baby) are only two dimensional. The Accuro is a three dimensional handheld ultrasound device. This device uses sound waves to create pictures of the spine in three dimensions. This may allow the physician to view the spine in more detail for procedures such as spinal anesthesia and other diagnostic procedures. Epidural analgesia is the mainstay procedure for the management of labor pain. The precise placement of a needle or catheter in proximity to landmarks of the spinal bone anatomy is required for the procedure to succeed. The current standard of care is called the 'blind approach' (i.e. without medical imaging) and involves a physician manually palpating a patient's back to locate spinal bone landmarks. The needle is then inserted with respect to the location of the landmarks and inserted until a loss-of-resistance is manually detected. This approach, while most common, has been associated with success rates as low as 68% in obese patients (2).
Alternative methods have been investigated for this problem, including ultrasound (US) guidance, which offers real-time imaging. Several studies have demonstrated ultrasound's efficacy for spinal anesthesia (1-6). However, standard US systems are engineered to image soft tissue rather than bone structures, with the consequence that bone is imaged poorly. US images are often degraded by a number of noise sources including speckle noise, reverberations and off-axis scattering, particularly when bone is present, making visualization of bone anatomy features difficult. Moreover, arranging access to ultrasound for the purpose of spinal anesthesia alone is cumbersome. Thus, the efficacy of guided spinal anesthesia and diagnostic procedures using standard ultrasound systems is limited and the benefits that it offers are heavily dependent on the user's familiarity and skill with ultrasonography (4).
Recently, new medical imaging technologies have been developed at Rivanna Medical, LLC to address the significant clinical need for technological advances that improve the placement of spinal anesthesia, epidural analgesia and other diagnostic procedures. The Accuro is a pocket-sized and battery operated ultrasound instrument that incorporates new signal processing-based technologies for enhanced bone imaging including 3D navigation of the lumbar spine. The device is a single self-contained unit consisting of an ultrasound system, ultrasound probe, and rotatable touchscreen display. The instrument enables a SpineView3D™ technology to facilitate spinal anesthesia guidance with real-time 3D navigation of the lumbar spine anatomy.
SpineView3D™ technology facilitates image interpretation of individual 2D lumbar spine scans by automating spinal bone landmark detection and depth measurements and providing a real-time assessment of scan plane orientation in 3D. SpineView3D™ makes image interpretation and measurements of the lumbar spine anatomy simple, quick, and easy. Real-time 2D scans from either SpineView3D™ or general-purpose bone presets are formed using patent-pending BoneEnhance+™ technology. The BoneEnhance+™ technology provides images of bone anatomy at greater bone-to-tissue contrast compared with conventional ultrasound image reconstructions.
Visão geral do estudo
Status
Condições
Tipo de estudo
Inscrição (Real)
Contactos e Locais
Locais de estudo
-
-
Virginia
-
Charlottesville, Virginia, Estados Unidos, 22908
- University of Virginia Health System
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
Patients between the ages of 18 and 40 presenting for delivery and planning epidural anesthesia
- ASA-1 and ASA-2
- BMI > 30
Exclusion Criteria:
Patients with known spinal deformities allergies to ultrasound gel
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
Coortes e Intervenções
Grupo / Coorte |
Intervenção / Tratamento |
|---|---|
|
Control group (CG):
Standard practice group
|
Standard practice group
Outros nomes:
|
|
Ultrasound group (UG):
SpineView3D™ anatomical "scouting" approach
|
SpineView3D™ anatomical "scouting" approach
Outros nomes:
subject will be scanned with 'Accuro SpineView3D
Outros nomes:
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Success rates:
Prazo: 1 day
|
defined as successful epidural administration on the first needle insertion attempt.
|
1 day
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Investigadores
- Investigador principal: Mohammed Tiouririne, MD, UVA Health System
Publicações e links úteis
Publicações Gerais
- Chin KJ, Perlas A, Chan V, Brown-Shreves D, Koshkin A, Vaishnav V. Ultrasound imaging facilitates spinal anesthesia in adults with difficult surface anatomic landmarks. Anesthesiology. 2011 Jul;115(1):94-101. doi: 10.1097/ALN.0b013e31821a8ad4.
- Vallejo MC, Phelps AL, Singh S, Orebaugh SL, Sah N. Ultrasound decreases the failed labor epidural rate in resident trainees. Int J Obstet Anesth. 2010 Oct;19(4):373-8. doi: 10.1016/j.ijoa.2010.04.002. Epub 2010 Aug 8.
- Grau T, Bartusseck E, Conradi R, Martin E, Motsch J. Ultrasound imaging improves learning curves in obstetric epidural anesthesia: a preliminary study. Can J Anaesth. 2003 Dec;50(10):1047-50. doi: 10.1007/BF03018371.
- Grau T, Leipold RW, Conradi R, Martin E. Ultrasound control for presumed difficult epidural puncture. Acta Anaesthesiol Scand. 2001 Jul;45(6):766-71. doi: 10.1034/j.1399-6576.2001.045006766.x.
- Chin KJ, Karmakar MK, Peng P. Ultrasonography of the adult thoracic and lumbar spine for central neuraxial blockade. Anesthesiology. 2011 Jun;114(6):1459-85. doi: 10.1097/ALN.0b013e318210f9f8.
- Karmakar MK. Ultrasound for central neuroaxial blocks. Techniques in regional anesthesia and pain management 2009;13:161-70.
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo
Conclusão Primária (Real)
Conclusão do estudo (Real)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Estimativa)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Outros números de identificação do estudo
- Rivanna Clin-002
Plano para dados de participantes individuais (IPD)
Planeja compartilhar dados de participantes individuais (IPD)?
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .
Ensaios clínicos em Control group (CG): standard practice
-
Fu Jen Catholic University HospitalRecrutamentoDoença Renal Crônica (DRC) | CKD Estágio 1-3Taiwan
-
Universita di VeronaRecrutamentoEsclerose múltipla | Reabilitação | Déficit Cognitivo | Déficits MotoresItália
-
University of ZurichSchweizerischer NationalfondsRecrutamento
-
MRC/UVRI and LSHTM Uganda Research UnitUniversity of British Columbia; The AIDS Support Organization; University of CaliforniaRecrutamentoComportamento adolescente | Modificação do estilo de vida | Doenças Cardiovasculares OutrasUganda