Handheld 3D Lumbar Spine Navigation: A Clinical Validation Study RM002
Currently, at UVA, handheld ultrasound devices (like those used to view an unborn baby) are only two dimensional. The Accuro is a three dimensional handheld ultrasound device. This device uses sound waves to create pictures of the spine in three dimensions. This may allow the physician to view the spine in more detail for procedures such as spinal anesthesia and other diagnostic procedures. Epidural analgesia is the mainstay procedure for the management of labor pain. The precise placement of a needle or catheter in proximity to landmarks of the spinal bone anatomy is required for the procedure to succeed. The current standard of care is called the 'blind approach' (i.e. without medical imaging) and involves a physician manually palpating a patient's back to locate spinal bone landmarks. The needle is then inserted with respect to the location of the landmarks and inserted until a loss-of-resistance is manually detected. This approach, while most common, has been associated with success rates as low as 68% in obese patients (2).
Alternative methods have been investigated for this problem, including ultrasound (US) guidance, which offers real-time imaging. Several studies have demonstrated ultrasound's efficacy for spinal anesthesia (1-6). However, standard US systems are engineered to image soft tissue rather than bone structures, with the consequence that bone is imaged poorly. US images are often degraded by a number of noise sources including speckle noise, reverberations and off-axis scattering, particularly when bone is present, making visualization of bone anatomy features difficult. Moreover, arranging access to ultrasound for the purpose of spinal anesthesia alone is cumbersome. Thus, the efficacy of guided spinal anesthesia and diagnostic procedures using standard ultrasound systems is limited and the benefits that it offers are heavily dependent on the user's familiarity and skill with ultrasonography (4).
Recently, new medical imaging technologies have been developed at Rivanna Medical, LLC to address the significant clinical need for technological advances that improve the placement of spinal anesthesia, epidural analgesia and other diagnostic procedures. The Accuro is a pocket-sized and battery operated ultrasound instrument that incorporates new signal processing-based technologies for enhanced bone imaging including 3D navigation of the lumbar spine. The device is a single self-contained unit consisting of an ultrasound system, ultrasound probe, and rotatable touchscreen display. The instrument enables a SpineView3D™ technology to facilitate spinal anesthesia guidance with real-time 3D navigation of the lumbar spine anatomy.
SpineView3D™ technology facilitates image interpretation of individual 2D lumbar spine scans by automating spinal bone landmark detection and depth measurements and providing a real-time assessment of scan plane orientation in 3D. SpineView3D™ makes image interpretation and measurements of the lumbar spine anatomy simple, quick, and easy. Real-time 2D scans from either SpineView3D™ or general-purpose bone presets are formed using patent-pending BoneEnhance+™ technology. The BoneEnhance+™ technology provides images of bone anatomy at greater bone-to-tissue contrast compared with conventional ultrasound image reconstructions.
Studie Overzicht
Toestand
Conditie
Interventie / Behandeling
Studietype
Inschrijving (Werkelijk)
Contacten en locaties
Studie Locaties
-
-
Virginia
-
Charlottesville, Virginia, Verenigde Staten, 22908
- University of Virginia Health System
-
-
Deelname Criteria
Geschiktheidscriteria
Leeftijden die in aanmerking komen voor studie
Accepteert gezonde vrijwilligers
Geslachten die in aanmerking komen voor studie
Bemonsteringsmethode
Studie Bevolking
Beschrijving
Inclusion Criteria:
Patients between the ages of 18 and 40 presenting for delivery and planning epidural anesthesia
- ASA-1 and ASA-2
- BMI > 30
Exclusion Criteria:
Patients with known spinal deformities allergies to ultrasound gel
Studie plan
Hoe is de studie opgezet?
Ontwerpdetails
Cohorten en interventies
Groep / Cohort |
Interventie / Behandeling |
|---|---|
|
Control group (CG):
Standard practice group
|
Standard practice group
Andere namen:
|
|
Ultrasound group (UG):
SpineView3D™ anatomical "scouting" approach
|
SpineView3D™ anatomical "scouting" approach
Andere namen:
subject will be scanned with 'Accuro SpineView3D
Andere namen:
|
Wat meet het onderzoek?
Primaire uitkomstmaten
Uitkomstmaat |
Maatregel Beschrijving |
Tijdsspanne |
|---|---|---|
|
Success rates:
Tijdsspanne: 1 day
|
defined as successful epidural administration on the first needle insertion attempt.
|
1 day
|
Medewerkers en onderzoekers
Sponsor
Medewerkers
Onderzoekers
- Hoofdonderzoeker: Mohammed Tiouririne, MD, UVA Health System
Publicaties en nuttige links
Algemene publicaties
- Chin KJ, Perlas A, Chan V, Brown-Shreves D, Koshkin A, Vaishnav V. Ultrasound imaging facilitates spinal anesthesia in adults with difficult surface anatomic landmarks. Anesthesiology. 2011 Jul;115(1):94-101. doi: 10.1097/ALN.0b013e31821a8ad4.
- Vallejo MC, Phelps AL, Singh S, Orebaugh SL, Sah N. Ultrasound decreases the failed labor epidural rate in resident trainees. Int J Obstet Anesth. 2010 Oct;19(4):373-8. doi: 10.1016/j.ijoa.2010.04.002. Epub 2010 Aug 8.
- Grau T, Bartusseck E, Conradi R, Martin E, Motsch J. Ultrasound imaging improves learning curves in obstetric epidural anesthesia: a preliminary study. Can J Anaesth. 2003 Dec;50(10):1047-50. doi: 10.1007/BF03018371.
- Grau T, Leipold RW, Conradi R, Martin E. Ultrasound control for presumed difficult epidural puncture. Acta Anaesthesiol Scand. 2001 Jul;45(6):766-71. doi: 10.1034/j.1399-6576.2001.045006766.x.
- Chin KJ, Karmakar MK, Peng P. Ultrasonography of the adult thoracic and lumbar spine for central neuraxial blockade. Anesthesiology. 2011 Jun;114(6):1459-85. doi: 10.1097/ALN.0b013e318210f9f8.
- Karmakar MK. Ultrasound for central neuroaxial blocks. Techniques in regional anesthesia and pain management 2009;13:161-70.
Studie record data
Bestudeer belangrijke data
Studie start
Primaire voltooiing (Werkelijk)
Studie voltooiing (Werkelijk)
Studieregistratiedata
Eerst ingediend
Eerst ingediend dat voldeed aan de QC-criteria
Eerst geplaatst (Schatting)
Updates van studierecords
Laatste update geplaatst (Werkelijk)
Laatste update ingediend die voldeed aan QC-criteria
Laatst geverifieerd
Meer informatie
Termen gerelateerd aan deze studie
Andere studie-ID-nummers
- Rivanna Clin-002
Plan Individuele Deelnemersgegevens (IPD)
Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?
Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .
Klinische onderzoeken op Control group (CG): standard practice
-
Superior UniversityActief, niet wervend
-
Universita di VeronaWervingMultiple sclerose | Revalidatie | Cognitieve tekortkoming | Motorische tekortkomingenItalië
-
Fu Jen Catholic University HospitalWervingChronische nierziekte (CKD) | CKD Stadium 1-3Taiwan
-
Ospedale Policlinico San MartinoItalian Multiple Sclerosis FoundationWervingMultiple sclerose | Cognitieve beperkingItalië
-
OrganogenesisVoltooidVeneuze zweerVerenigde Staten
-
University of NebraskaVoltooidStoppen met roken | Stoornis in het gebruik van middelenVerenigde Staten
-
Johns Hopkins Bloomberg School of Public HealthNative American Research Centers for Health (NARCH)VoltooidDepressieve symptomen | Substantie gebruikVerenigde Staten
-
Sun Yat-sen UniversityNog niet aan het werven
-
University of ArkansasIngetrokkenMeibomse klierdisfunctieVerenigde Staten
-
Konya Meram State HospitalVoltooidCervicogene hoofdpijnTurkije (Türkiye)